DETECTION OF CANINE INTERLEUKIN-2 RECEPTORS BY FLOW-CYTOMETRY

被引:21
|
作者
SOMBERG, RL [1 ]
ROBINSON, JP [1 ]
FELSBURG, PJ [1 ]
机构
[1] PURDUE UNIV,SCH VET MED,DEPT VET PHYSIOL & PHARMACOL,W LAFAYETTE,IN 47907
关键词
D O I
10.1016/0165-2427(92)90031-K
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
This study describes a method for detecting canine interleukin-2 receptors (IL-2R) by flow cytometry, using human recombinant IL-2 labeled with phycoerythrin (IL-2-PE). Peripheral blood mononuclear cells from four normal dogs were washed, incubated with IL-2-PE, and then washed to remove any unbound IL-2-PE. Flow cytometric analysis of the cells was performed with a 488 nm argon laser while gating on lymphocytes. Cells expressing the IL-2R were identified by their fluorescence as compared to cells stained with an anti-mouse immunoglobulin-G conjugated to phycoerythrin. The average percentage of resting cells expressing the IL-2R was found to be 21%. The addition of unlabeled human recombinant IL-2 to Day 3 phytohemagglutinin (PHA)-stimulated cells reduced the fluorescence intensity four-fold, thereby demonstrating the specificity of IL-2-PE for canine IL-2R. Following stimulation with optimal concentrations of PHA, the percentage of cells expressing the IL-2R increased daily and reached a maximum on Day 3 (76.4%). IL-2R density, as measured by mean fluorescence intensity, also increased and reached maximal levels on Days 2-3 (twenty-fold greater than resting cells). The binding, inhibition, and kinetic experiments provide evidence that human recombinant IL-2-PE is a useful tool for studying canine IL-2R expression. Thus, a one-step direct method for the flow cytometric detection and quantification of the canine IL-2R is now available.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [1] BIOTINYLATION OF HUMAN INTERLEUKIN-2 FOR FLOW-CYTOMETRY ANALYSIS OF INTERLEUKIN-2 RECEPTORS
    TAKI, S
    SHIMAMURA, T
    ABE, M
    SHIRAI, T
    TAKAHARA, Y
    JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 122 (01) : 33 - 41
  • [2] AN IMPROVED METHOD FOR THE DETECTION OF SOLUBLE INTERLEUKIN-2 RECEPTORS IN LIVER-TRANSPLANT RECIPIENTS BY FLOW-CYTOMETRY
    COHEN, N
    GUMBERT, M
    BIRNBAUM, J
    LIM, VL
    FALCO, D
    ASCHER, N
    ROBERTS, J
    GAROVOY, MR
    TRANSPLANTATION, 1991, 51 (02) : 417 - 421
  • [3] DETECTION OF CYTOKINE RECEPTORS ON CHONDROCYTES BY FLOW-CYTOMETRY
    WESTACOTT, CI
    ATKINS, RM
    LANGKAMER, G
    DIEPPE, PA
    ELSON, CJ
    ARTHRITIS AND RHEUMATISM, 1992, 35 (09): : S311 - S311
  • [4] DETECTION OF INTRACELLULAR INTERLEUKIN-10 BY FLOW-CYTOMETRY
    KREFT, B
    SINGER, GG
    DIAZGALLO, C
    KELLEY, VR
    JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 156 (01) : 125 - 128
  • [5] FLOW-CYTOMETRY ANALYSIS OF EARLY BIOCHEMICAL EVENTS INVOLVED IN INTERLEUKIN-2 (IL-2) SYNTHESIS
    WILLIAMS, DB
    DORRINGTON, KJ
    KLEIN, M
    FEDERATION PROCEEDINGS, 1985, 44 (04) : 950 - 950
  • [6] DETECTION OF INDIVIDUAL INTERLEUKIN-PRODUCING CELLS BY FLOW-CYTOMETRY
    ANDERSSON, U
    SANDER, B
    ANDERSSON, J
    EOS-RIVISTA DI IMMUNOLOGIA ED IMMUNOFARMACOLOGIA, 1990, 10 (04): : 115 - 116
  • [7] FLOW-CYTOMETRY IN MALARIA DETECTION
    JANSE, CJ
    VANVIANEN, PH
    METHODS IN CELL BIOLOGY, VOL 42, 1994, 42 : 295 - 318
  • [8] DETECTION OF INTERLEUKIN-2 RECEPTORS ON MURINE LYMPHOCYTES USING FLUORESCENT INTERLEUKIN-2
    JADUS, MR
    HORANSKY, E
    WEPSIC, HT
    IMMUNOLOGY LETTERS, 1992, 34 (02) : 127 - 134
  • [9] DETECTION OF CYTOKINE RECEPTORS BY HIGH-SENSITIVITY IMMUNOFLUORESCENCE FLOW-CYTOMETRY
    ZOLA, H
    FLEGO, L
    SHELDON, A
    IMMUNOBIOLOGY, 1992, 185 (2-4) : 350 - 365
  • [10] FLOW CYTOMETRIC DETECTION OF INTERLEUKIN-2 RECEPTORS ON MURINE LYMPHOCYTES USING FLUORESCENT INTERLEUKIN-2 (IL2F)
    JADUS, MR
    HORANSKY, E
    WEPSIC, HT
    FASEB JOURNAL, 1992, 6 (05): : A1604 - A1604