The Influence of Physiological Noise Correction on Test-Retest Reliability of Resting-State Functional Connectivity

被引:64
作者
Birn, Rasmus M. [1 ,2 ,3 ]
Cornejo, Maria Daniela [2 ]
Molloy, Erin K. [1 ]
Patriat, Remi [2 ]
Meier, Timothy B. [7 ]
Kirk, Gregory R. [4 ]
Nair, Veena A. [5 ]
Meyerand, M. Elizabeth [2 ,3 ,5 ,6 ]
Prabhakaran, Vivek [1 ,3 ,5 ]
机构
[1] Univ Wisconsin, Dept Psychiat, 6001 Res Pk Blvd, Madison, WI 53719 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Neurosci Training Program, Madison, WI USA
[4] Univ Wisconsin, Waisman Lab Brain Imaging & Behav, Madison, WI USA
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[7] Laureate Inst Brain Res, Tulsa, OK USA
关键词
cardiac; functional connectivity; physiological noise; reliability; respiration; resting state;
D O I
10.1089/brain.2014.0284
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The utility and success of resting-state functional connectivity MRI (rs-fcMRI) depend critically on the reliability of this technique and the extent to which it accurately reflects neuronal function. One challenge is that rs-fcMRI is influenced by various sources of noise, particularly cardiac- and respiratory-related signal variations. The goal of the current study was to evaluate the impact of various physiological noise correction techniques, specifically those that use independent cardiac and respiration measures, on the test-retest reliability of rs-fcMRI. A group of 25 subjects were each scanned at three time points-two within the same imaging session and another 2-3 months later. Physiological noise corrections accounted for significant variance, particularly in blood vessels, sagittal sinus, cerebrospinal fluid, and gray matter. The fraction of variance explained by each of these corrections was highly similar within subjects between sessions, but variable between subjects. Physiological corrections generally reduced intrasubject (between-session) variability, but also significantly reduced intersubject variability, and thus reduced the test-retest reliability of estimating individual differences in functional connectivity. However, based on known nonneuronal mechanisms by which cardiac pulsation and respiration can lead to MRI signal changes, and the observation that the physiological noise itself is highly stable within individuals, removal of this noise will likely increase the validity of measured connectivity differences. Furthermore, removal of these fluctuations will lead to better estimates of average or group maps of connectivity. It is therefore recommended that studies apply physiological noise corrections but also be mindful of potential correlations with measures of interest.
引用
收藏
页码:511 / 522
页数:12
相关论文
共 63 条
  • [1] Network Anticorrelations, Global Regression, and Phase-Shifted Soft Tissue Correction
    Anderson, Jeffrey S.
    Druzgal, T. Jason
    Lopez-Larson, Melissa
    Jeong, Eun-Kee
    Desai, Krishnaji
    Yurgelun-Todd, Deborah
    [J]. HUMAN BRAIN MAPPING, 2011, 32 (06) : 919 - 934
  • [2] Isolating physiologic noise sources with independently determined spatial measures
    Beall, Erik B.
    Lowe, Mark J.
    [J]. NEUROIMAGE, 2007, 37 (04) : 1286 - 1300
  • [3] A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
    Behzadi, Yashar
    Restom, Khaled
    Liau, Joy
    Liu, Thomas T.
    [J]. NEUROIMAGE, 2007, 37 (01) : 90 - 101
  • [4] Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study
    Bianciardi, Marta
    Fukunaga, Masaki
    van Gelderen, Peter
    Horovitz, Silvina G.
    de Zwart, Jacco A.
    Shmueli, Karin
    Duyn, Jeff H.
    [J]. MAGNETIC RESONANCE IMAGING, 2009, 27 (08) : 1019 - 1029
  • [5] The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration
    Birn, Rasmus M.
    Smith, Monica A.
    Jones, Tyler B.
    Bandettini, Peter A.
    [J]. NEUROIMAGE, 2008, 40 (02) : 644 - 654
  • [6] The effect of scan length on the reliability of resting-state fMRI connectivity estimates
    Birn, Rasmus M.
    Molloy, Erin K.
    Patriat, Remi
    Parker, Taurean
    Meier, Timothy B.
    Kirk, Gregory R.
    Nair, Veena A.
    Meyerand, M. Elizabeth
    Prabhakaran, Vivek
    [J]. NEUROIMAGE, 2013, 83 : 550 - 558
  • [7] The role of physiological noise in resting-state functional connectivity
    Birn, Rasmus M.
    [J]. NEUROIMAGE, 2012, 62 (02) : 864 - 870
  • [8] Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI
    Birn, RM
    Diamond, JB
    Smith, MA
    Bandettini, PA
    [J]. NEUROIMAGE, 2006, 31 (04) : 1536 - 1548
  • [9] FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI
    BISWAL, B
    YETKIN, FZ
    HAUGHTON, VM
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 537 - 541
  • [10] Test-retest reliability of resting-state connectivity network characteristics using fMRI and graph theoretical measures
    Braun, Urs
    Plichta, Michael M.
    Esslinger, Christine
    Sauer, Carina
    Haddad, Leila
    Grimm, Oliver
    Mier, Daniela
    Mohnke, Sebastian
    Heinz, Andreas
    Erk, Susanne
    Walter, Henrik
    Seiferth, Nina
    Kirsch, Peter
    Meyer-Lindenberg, Andreas
    [J]. NEUROIMAGE, 2012, 59 (02) : 1404 - 1412