NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING

被引:345
|
作者
SEMELKA, RC [1 ]
TOMEI, E [1 ]
WAGNER, S [1 ]
MAYO, J [1 ]
KONDO, C [1 ]
SUZUKI, J [1 ]
CAPUTO, GR [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,C309,SAN FRANCISCO,CA 94143
关键词
Heart; ejection fraction; flow dynamics; function; MR studies; 524.1214; ventricles; volume; Magnetic resonance (MR); cine study;
D O I
10.1148/radiology.174.3.2305059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated the reproducibility of measurements of ventricular dimensions obtained with cine magnetic resonance (MR) imaging performed on two occasions in 11 healthy subjects. Two reviewers analyzed the studies in a blinded fashion to determine interobserver and interstudy variability of measurements of left ventricular (LV) mass, volume, ejection fraction, and systolic wall stress. LV mass showed good reproducibility between studies, with 3.6% and 3.8% variability for LV end-systolic mass for the two observers. LV end-diastolic volume varied by 5.2% and 3.9%, and LV end-systolic volume, by 9.7% and 9.0%. Variability for LV ejection fraction was 5.0% and 4.9%. The largest interstudy variability was end-systolic wall stress, 11.1% and 13.5%, which was due mostly to changes in arterial pressure between the two studies. It is concluded that anatomic and functional measurements from cine MR images are reproducible between studies. The small interstudy variability is likely related to the fact that the measurements are derived directly from cine MR images that encompass the entire heart rather than depend on measurements of only sample images and the use of geometric models.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 50 条
  • [41] A simplified method for the determination of left atrial size and function using cine magnetic resonance imaging
    Jarvinen, VM
    Kupari, MM
    Poutanen, VP
    Hekali, PE
    MAGNETIC RESONANCE IMAGING, 1996, 14 (03) : 215 - 226
  • [42] LEFT-VENTRICULAR THROMBI - EVALUATION WITH SPIN-ECHO AND GRADIENT-ECHO MR IMAGING
    JUNGEHULSING, M
    SECHTEM, U
    THEISSEN, P
    HILGER, HH
    SCHICHA, H
    RADIOLOGY, 1992, 182 (01) : 225 - 229
  • [43] Effect of temporal resolution on the estimation of left ventricular function by cardiac MR imaging
    Inoue, Y
    Nomura, Y
    Nakaoka, T
    Watanabe, M
    Kiryu, S
    Okubo, T
    Ohtomo, K
    MAGNETIC RESONANCE IMAGING, 2005, 23 (05) : 641 - 645
  • [44] LEFT-VENTRICULAR DIASTOLIC FUNCTION IN THE NORMAL AND DISEASED HEART - PERSPECTIVES FOR THE ANESTHESIOLOGIST .2.
    PAGEL, PS
    GROSSMAN, W
    HAERING, JM
    WARLTIER, DC
    ANESTHESIOLOGY, 1993, 79 (05) : 1104 - 1120
  • [45] EVALUATION OF LEFT-VENTRICULAR FUNCTION DURING EJECTION
    STEIN, PD
    SABBAH, HN
    ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (01) : 127 - 138
  • [46] Improving the reproducibility of MR-derived left ventricular volume and function measurements with a semi-automatic threshold-based segmentation algorithm
    Karolien Jaspers
    Hendrik G. Freling
    Kees van Wijk
    Elisabeth I. Romijn
    Marcel J. W. Greuter
    Tineke P. Willems
    The International Journal of Cardiovascular Imaging, 2013, 29 : 617 - 623
  • [47] The Reproducibility and Absolute Values of Echocardiographic Measurements of Left Ventricular Size and Function in Children Are Algorithm Dependent
    Margossian, Renee
    Chen, Shan
    Sleeper, Lynn A.
    Tani, Lloyd Y.
    Shirali, Girish
    Golding, Fraser
    Tierney, Elif Seda Selamet
    Altmann, Karen
    Campbell, Michael J.
    Szwast, Anita
    Sharkey, Angela
    Radojewski, Elizabeth
    Colan, Steven D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (05) : 549 - U137
  • [48] Three-dimensional systolic strain patterns in the normal human left ventricle: Characterization with tagged MR imaging
    Moore, CC
    Lugo-Olivieri, CH
    McVeigh, ER
    Zerhouni, EA
    RADIOLOGY, 2000, 214 (02) : 453 - 466
  • [49] Accurate quantification of right ventricular mass at MR imaging by using cine true fast imaging with steady-state precession:: Study in dogs
    Shors, SM
    Fung, CW
    François, CJ
    Finn, JP
    Fieno, DS
    RADIOLOGY, 2004, 230 (02) : 383 - 388
  • [50] UK audit of quantification of left-ventricular function using gated myocardial perfusion imaging
    Cade, Sarah C.
    Hall, David O.
    Kenny, Bob
    Knight, Andy
    Lawson, Richard S.
    Livieratos, Lefteris
    Nijran, Kuldip S.
    White, Duncan
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (10) : 990 - 1004