NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING

被引:345
|
作者
SEMELKA, RC [1 ]
TOMEI, E [1 ]
WAGNER, S [1 ]
MAYO, J [1 ]
KONDO, C [1 ]
SUZUKI, J [1 ]
CAPUTO, GR [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,C309,SAN FRANCISCO,CA 94143
关键词
Heart; ejection fraction; flow dynamics; function; MR studies; 524.1214; ventricles; volume; Magnetic resonance (MR); cine study;
D O I
10.1148/radiology.174.3.2305059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors evaluated the reproducibility of measurements of ventricular dimensions obtained with cine magnetic resonance (MR) imaging performed on two occasions in 11 healthy subjects. Two reviewers analyzed the studies in a blinded fashion to determine interobserver and interstudy variability of measurements of left ventricular (LV) mass, volume, ejection fraction, and systolic wall stress. LV mass showed good reproducibility between studies, with 3.6% and 3.8% variability for LV end-systolic mass for the two observers. LV end-diastolic volume varied by 5.2% and 3.9%, and LV end-systolic volume, by 9.7% and 9.0%. Variability for LV ejection fraction was 5.0% and 4.9%. The largest interstudy variability was end-systolic wall stress, 11.1% and 13.5%, which was due mostly to changes in arterial pressure between the two studies. It is concluded that anatomic and functional measurements from cine MR images are reproducible between studies. The small interstudy variability is likely related to the fact that the measurements are derived directly from cine MR images that encompass the entire heart rather than depend on measurements of only sample images and the use of geometric models.
引用
收藏
页码:763 / 768
页数:6
相关论文
共 50 条
  • [21] MR assessment of left ventricular function: Quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique
    Li, W
    Stern, JS
    Mai, VM
    Pierchala, LN
    Edelman, RR
    Prasad, PV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (05) : 559 - 564
  • [22] Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs
    François, CJ
    Fieno, DS
    Shors, SM
    Finn, JP
    RADIOLOGY, 2004, 230 (02) : 389 - 395
  • [23] Right and left atrial phasic volumetric function in mildly symptomatic dilated and hypertrophic cardiomyopathy: Cine MR imaging assessment
    Jarvinen, VM
    Kupari, MM
    Poutanen, VP
    Hekali, PE
    RADIOLOGY, 1996, 198 (02) : 487 - 495
  • [24] MR IMAGING OF APICAL HYPERTROPHIC CARDIOMYOPATHY WITH LEFT-VENTRICULAR ENDOMYOCARDIAL CALCIFICATION
    KVAERNESS, J
    RINCK, PA
    BOLZ, KD
    BATHEN, J
    SKJAERPE, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (03) : 489 - 491
  • [25] MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters
    Miller, S
    Simonetti, OP
    Carr, J
    Kramer, U
    Finn, JP
    RADIOLOGY, 2002, 223 (01) : 263 - 269
  • [26] Determination of left and right ventricular ejection and filling by fast cine MR imaging in the breath-hold technique in healthy subjects.
    Rominger, MB
    Bachmann, GF
    Geuer, M
    Puzik, M
    Pabst, W
    Rau, WS
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 436 - 441
  • [27] Left-ventricular reduction surgery: Pre- and postoperative evaluation by cine magnetic resonance imaging
    Kivelitz, DE
    Hotz, H
    Borges, AC
    Enzweiler, CNH
    Wiese, TH
    Lembcke, A
    Konertz, W
    Baumann, G
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 336 - 340
  • [28] Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function
    Daou, D
    Coaguila, C
    Benada, A
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (02) : 233 - 243
  • [29] Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    Moon, JCC
    Lorenz, CH
    Francis, JM
    Smith, GC
    Pennell, DJ
    RADIOLOGY, 2002, 223 (03) : 789 - 797
  • [30] Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: Comparison with precontrast cine-MR sequences. Results of a bicentric study
    Jean-Christophe Lasalarie
    Jean-Michel Serfaty
    Christophe Carre
    David Messika-Zeitoun
    Christophe Jeannot
    Elisabeth Schouman-Claeys
    Jean-Pierre Laissy
    European Radiology, 2007, 17 (11) : 2838 - 2844