A Novel Pulsatile Bioreactor for Mechanical Stimulation of Tissue Engineered Cardiac Constructs

被引:10
作者
Hollweck, Trixi [1 ]
Akra, Bassil [1 ]
Haeussler, Simon [1 ]
Ueberfuhr, Peter [1 ]
Schmitz, Christoph [1 ]
Pfeifer, Stefan [2 ]
Eblenkamp, Markus [2 ]
Wintermantel, Erich [2 ]
Eissner, Gunther [1 ]
机构
[1] Univ Munich, Dept Cardiac Surg, Marchioninistr 15, D-81377 Munich, Germany
[2] Tech Univ Munich, Chair Med Engn, D-85748 Garching, Germany
来源
JOURNAL OF FUNCTIONAL BIOMATERIALS | 2011年 / 2卷 / 03期
关键词
tissue engineering; bioreactor; mechanical stimulation; mesenchymal stem cells; cardiac differentiation; umbilical cord;
D O I
10.3390/jfb2030107
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
After myocardial infarction, the implantation of stem cell seeded scaffolds on the ischemic zone represents a promising strategy for restoration of heart function. However, mechanical integrity and functionality of tissue engineered constructs need to be determined prior to implantation. Therefore, in this study a novel pulsatile bioreactor mimicking the myocardial contraction was developed to analyze the behavior of mesenchymal stem cells derived from umbilical cord tissue (UCMSC) colonized on titanium-coated polytetrafluorethylene scaffolds to friction stress. The design of the bioreactor enables a simple handling and defined mechanical forces on three seeded scaffolds at physiological conditions. The compact system made of acrylic glass, Teflon (R), silicone, and stainless steel allows the comparison of different media, cells and scaffolds. The bioreactor can be gas sterilized and actuated in a standard incubator. Macroscopic observations and pressure-measurements showed a uniformly sinusoidal pulsation, indicating that the bioreactor performed well. Preliminary experiments to determine the adherence rate and morphology of UCMSC after mechanical loadings showed an almost confluent cellular coating without damage on the cell surface. In summary, the bioreactor is an adequate tool for the mechanical stress of seeded scaffolds and offers dynamic stimuli for pre-conditioning of cardiac tissue engineered constructs in vitro.
引用
收藏
页码:107 / 118
页数:12
相关论文
共 22 条
  • [11] A novel bioreactor for the dynamic flexural stimulation of tissue engineered heart valve biomaterials
    Engelmayr, GC
    Hildebrand, DK
    Sutherland, FWH
    Mayer, JE
    Sacks, MS
    [J]. BIOMATERIALS, 2003, 24 (14) : 2523 - 2532
  • [12] Chronic stretch of engineered heart tissue induces hypertrophy and functional improvement
    Fink, C
    Ergün, S
    Kralisch, D
    Remmers, U
    Weil, J
    Eschenhagen, T
    [J]. FASEB JOURNAL, 2000, 14 (05) : 669 - 679
  • [13] Freed LE, 1997, IN VITRO CELL DEV-AN, V33, P381
  • [14] Functional Tissue Engineering Requires Bioreactor Strategies Preface
    Goldstein, Aaron S.
    Christ, George
    [J]. TISSUE ENGINEERING PART A, 2009, 15 (04) : 739 - 740
  • [15] Umbilical cord tissue-derived mesenchymal stem cells grow best under GMP-compliant culture conditions and maintain their phenotypic and functional properties
    Hartmann, Isabel
    Hollweck, Trixi
    Haffner, Silvia
    Krebs, Michaela
    Meiser, Bruno
    Reichart, Bruno
    Eissner, Guenther
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2010, 363 (01) : 80 - 89
  • [16] Comparative analysis of adherence, viability, proliferation and morphology of umbilical cord tissue-derived mesenchymal stem cells seeded on different titanium-coated expanded polytetrafluoroethylene scaffolds
    Hollweck, Trixi
    Marschmann, Michaela
    Hartmann, Isabel
    Akra, Bassil
    Meiser, Bruno
    Reichart, Bruno
    Eblenkamp, Markus
    Wintermantel, Erich
    Eissner, Guenther
    [J]. BIOMEDICAL MATERIALS, 2010, 5 (06)
  • [17] Development of a novel pulsatile bioreactor for tissue culture
    Morsi, Yos S.
    Yang, William W.
    Owida, Amal
    Wong, Cynthia S.
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (02) : 109 - 114
  • [18] Method to isolate mesenchymal-like cells from Wharton's jelly of umbilical cord
    Seshareddy, Kiran
    Troyer, Deryl
    Weiss, Mark L.
    [J]. STEM CELL CULTURE, 2008, 86 : 101 - 119
  • [19] Cardiac tissue engineering, ex-vivo: Design principles in biomaterials and bioreactors
    Shachar, M
    Cohen, S
    [J]. HEART FAILURE REVIEWS, 2003, 8 (03) : 271 - 276
  • [20] Sodian R, 2001, J BIOMED MATER RES, V58, P401, DOI 10.1002/jbm.1034