THE SENSITIVITY IN ELECTRICAL IMPEDANCE TOMOGRAPHY

被引:0
|
作者
Rybin, A. I. [1 ,2 ]
Gaydayenko, E. V. [2 ]
Sushko, I. O. [2 ]
Gamanenko, A. I. [2 ]
机构
[1] Natl Tech Univ Ukraine, Kyiv Polytech Inst, Sci Tech, Kiev, Ukraine
[2] Natl Tech Univ Ukraine, Kyiv Polytech Inst, Kiev, Ukraine
关键词
phantom; the first - fourth type sensitivity; conductivity zones method; Electrical Impedance Tomography; inverse problem; regularization; increment; accuracy of measurement; inhomogeneity;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Introduction. The concept of sensitivity in Electrical Impedance Tomography is introduced (first - fourth type). The experimental researches measuring the voltages on the phantom outline are conducted on the created layout (for uniform cylindrical vessel with brine and placed inhomogeneities in a vessel). The main part. The inverse problems are solved for simulated on PC phantom (the third type sensitivity) and from measured results (the fourth type sensitivity) by conductivity zones method using regularization by A. Tykhonov. The sensitivity to conductivity increasing of elements inside the phantom is significantly less than the sensitivity to resistance increasing. The results of measured voltages processing and the results of projection reconstruction (obtained from mathematical model and from measured results) are described. Conclusions. The satisfactory agreements of reconstruction results between themselves and with mathematical and measured phantoms are shown.
引用
收藏
页码:107 / 117
页数:11
相关论文
共 50 条
  • [31] Electrical impedance tomography - Preface
    Barber, DC
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : U5 - U5
  • [32] Chest electrical impedance tomography
    Grigoriadis, K.
    Armaganidis, A.
    ARCHIVES OF HELLENIC MEDICINE, 2019, 36 (05): : 589 - 596
  • [33] Implementation of electrical impedance tomography
    Levin, A. I.
    Pecherskaya, E. A.
    Varenik, Yu. A.
    Shepeleva, J. V.
    ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2023, 16 (03): : 288 - 293
  • [34] A phantom for electrical impedance tomography
    Griffiths, H.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 15 - 20
  • [35] An electrical impedance tomography microscope
    Griffiths, H.
    Tucker, M.G.
    Sage, J.
    Herrenden-Harker, W.G.
    1996, Institute of Physics Publishing (17)
  • [36] An electrical impedance tomography microscope
    Griffiths, H
    Tucker, MG
    Sage, J
    HerrendenHarker, WG
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A15 - A24
  • [37] Rotational electrical impedance tomography
    Huang, Cheng-Ning
    Yu, Fang-Ming
    Chung, Hung-Yuan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (09) : 2958 - 2966
  • [38] A electrical impedance tomography system
    Peng, Y
    Mo, YL
    IEEE EMBS APBME 2003, 2003, : 280 - 281
  • [39] Electrical Impedance Tomography of Electrolysis
    Meir, Arie
    Rubinsky, Boris
    PLOS ONE, 2015, 10 (06):
  • [40] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855