THE EFFECT OF DENTAL PROPHYLAXIS INSTRUMENTS ON THE SURFACE-ROUGHNESS OF METALS USED FOR METAL-CERAMIC CROWNS

被引:10
|
作者
CUTLER, BJ [1 ]
GOLDSTEIN, GR [1 ]
SIMONELLI, G [1 ]
机构
[1] NYU,KRISER DENT CTR,DIV RESTORAT & PROSTHODONT SCI,NEW YORK,NY
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1995年 / 73卷 / 02期
关键词
D O I
10.1016/S0022-3913(05)80165-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Prophylactic instruments may cause surface deterioration of metal crown margins, which could cause or aid the retention and accumulation of plaque. In this investigation, highly polished metal disks of high content gold (RX Y), low content gold (Aspen), silver palladium (RX 91), and nickel-chrome alloy (REX III) had their surfaces tracked with an explorer, hand scaler, curette, and a Dentsply Cavitron instrument. The surface roughness was measured with a profilometer. The results indicate that the high content gold was the least resistant to surface deterioration and the ultrasonic scaler caused the most surface deterioration to all the metals.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [1] Retention of metal-ceramic crowns with contemporary dental cements
    Johnson, Glen H.
    Lepe, Xavier
    Zhang, Hai
    Wataha, John C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (09): : 1125 - 1136
  • [3] EFFECT OF METAL DESIGN ON MARGINAL DISTORTION OF METAL-CERAMIC CROWNS
    DEHOFF, PH
    ANUSAVICE, KJ
    JOURNAL OF DENTAL RESEARCH, 1984, 63 (11) : 1327 - 1331
  • [4] EFFECT OF INCOMPATIBILITY STRESS ON THE FIT OF METAL-CERAMIC CROWNS
    ANUSAVICE, KJ
    CARROLL, JE
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (08) : 1341 - 1345
  • [5] EFFECT OF PROPHYLAXIS INSTRUMENTATION ON ENAMEL SURFACE-ROUGHNESS
    NORLING, BK
    WILLMANN, DE
    JOURNAL OF DENTAL RESEARCH, 1979, 58 : 358 - 358
  • [6] SURFACE-ROUGHNESS EFFECT ON OPTICAL ABSORPTIVITY OF METALS
    BARBARINO, S
    GRASSO, F
    GUERRIERA, G
    MUSUMECI, F
    SCORDINO, A
    TRIGLIA, A
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1982, 29 (02): : 77 - 80
  • [7] TESTING OF CALIBRATION SPECIMENS USED WITH STYLUS INSTRUMENTS FOR MEASURING SURFACE-ROUGHNESS
    DUSMAN, F
    MAHOVIC, S
    MUDRONJA, V
    STANCEC, R
    STROJARSTVO, 1985, 27 (02): : 67 - 71
  • [8] Tracing the corrosion processes of different metal-ceramic dental crowns by EIS and SEM investigation
    Andrei, Mihai
    Gheorghe, Daniel
    Voicu, Georgeta
    Pîrvu, Cristian
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2015, 77 (04): : 113 - 122
  • [9] TRACING THE CORROSION PROCESSES OF DIFFERENT METAL-CERAMIC DENTAL CROWNS BY EIS AND SEM INVESTIGATION
    Andrei, Mihai
    Gheorghe, Daniel
    Voicu, Georgeta
    Pirvu, Cristian
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2015, 77 (04): : 113 - 122
  • [10] THE EFFECT OF SURFACE-ROUGHNESS ON FITTING STRENGTH OF SHRINK FIT BETWEEN CERAMIC AND METAL ELEMENTS
    KATO, K
    KAYABA, T
    NITTA, I
    SHIMODA, S
    JOURNAL OF VIBRATION ACOUSTICS STRESS AND RELIABILITY IN DESIGN-TRANSACTIONS OF THE ASME, 1989, 111 (03): : 318 - 325