OVERESTIMATION OF SERUM VANCOMYCIN CONCENTRATIONS USING A FLUORESCENCE POLARIZATION IMMUNOASSAY (TDX) IN PRETERM NEONATES

被引:0
|
作者
PAAP, CM
SHARPE, GL
机构
[1] UNIV TEXAS,COLL PHARM,AUSTIN,TX 78712
[2] CHILDRENS HOSP AUSTIN,CENT TEXAS MED FDN,AUSTIN,TX
来源
关键词
VANCOMYCIN; NEONATES; IMMUNOASSAY;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Serum vancomycin concentrations determined by fluorescence polarization immunoassay (FPIA) with a specific highperformance liquid chromatography (HPLC) method in preterm neonates were compared. Preterm neonates (<38 weeks gestational age) requiring vancomycin therapy and serum vancomycin concentration monitoring were enrolled. Peak serum vancomycin concentration samples were collected and independently analyzed by FPIA and HPLC. Multivariate and stratified data analysis was done with mean absolute error and mean percent error as dependent variables and independent variables as postconceptional age, postnatal age, gestational age, weight, and duration of therapy to characterize the findings. A total of 15 paired vancomycin concentrations were analyzed from neonates with a mean gestational age of 30 +/- 4 weeks. The mean percentage error of Fl?IA versus HPLC vancomycin concentrations was 18.1 +/- 11.1% and the mean absolute error was 3.7 +/- 2.0 mg/l. Postconceptional age, weight, and time from initiation of therapy to sample collection were independent variables which best characterized the overestimation of FPIA vancomycin concentrations. The FPIA vancomycin assay method overestimated actual vancomycin concentrations in preterm neonates. Preterm neonates less than 30 weeks postconceptional age, less than 1,200 g body weight, and duration of therapy greater than 48 h prior to concentration determination had the greatest difference in FPIA and HPLC results. Significant error in pharmacokinetic parameter estimations and dosage adjustments is possible when vancomycin concentrations are determined by FPIA.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 50 条
  • [31] Topical application of eosin to burns produces interference in measurement of serum vancomycin by fluorescence polarization immunoassay
    Leal, T
    Dupret, P
    Hassoun, A
    Wallemacq, PE
    CLINICAL CHEMISTRY, 1997, 43 (07) : 1238 - 1240
  • [32] MULTIPLE-DRUGS OF ABUSE DETECTION BY FLUORESCENCE POLARIZATION IMMUNOASSAY (FPIA) USING TDX REAGENT MIXTURE
    MUDARRIS, A
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1164 - 1164
  • [33] Inadequate vancomycin therapy in term and preterm neonates: a retrospective analysis of trough serum concentrations in relation to minimal inhibitory concentrations
    Sinkeler, Fleur S.
    de Haan, Timo R.
    Hodiamont, Caspar J.
    Bijleveld, Yuma A.
    Pajkrt, Dasja
    Mathot, Ron A. A.
    BMC PEDIATRICS, 2014, 14
  • [34] Inadequate vancomycin therapy in term and preterm neonates: a retrospective analysis of trough serum concentrations in relation to minimal inhibitory concentrations
    Fleur S Sinkeler
    Timo R de Haan
    Caspar J Hodiamont
    Yuma A Bijleveld
    Dasja Pajkrt
    Ron A A Mathôt
    BMC Pediatrics, 14
  • [35] BAYESIAN FORECASTING OF SERUM VANCOMYCIN CONCENTRATIONS IN NEONATES AND INFANTS
    RODVOLD, KA
    GENTRY, CA
    PLANK, GS
    KRAUS, DM
    NICKEL, E
    GROSS, JR
    THERAPEUTIC DRUG MONITORING, 1995, 17 (03) : 239 - 246
  • [36] Comparison of a New Serum Topiramate Immunoassay to Fluorescence Polarization Immunoassay
    Snozek, Christine L. H.
    Rollins, Lisa A.
    Peterson, Paul W.
    Langman, Loralie J.
    THERAPEUTIC DRUG MONITORING, 2010, 32 (01) : 107 - 111
  • [37] DEVELOPMENT OF A TDX/ADX FLUORESCENCE POLARIZATION IMMUNOASSAY FOR THE DETECTION OF METHADONE IN HUMAN-URINE
    THACKER, S
    DUBLER, R
    WANG, N
    WALLING, J
    CHIAPPETTA, E
    GATES, T
    CRISAFULLI, T
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1176 - 1176
  • [38] SERUM PENTOBARBITAL DETERMINATION BY FLUORESCENCE POLARIZATION IMMUNOASSAY
    SHIHABI, ZK
    SMITH, BL
    CLINICAL CHEMISTRY, 1987, 33 (06) : 1026 - 1026
  • [39] PERFORMANCE OF A FLUORESCENCE POLARIZATION IMMUNOASSAY FOR TEICOPLANIN IN SERUM
    MASTIN, SH
    BUCK, RL
    MUEGGLER, PA
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1993, 16 (01) : 17 - 24
  • [40] FLUORESCENCE POLARIZATION IMMUNOASSAY FOR DIGOXIN IN SERUM OR PLASMA
    BENNETT, L
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1982, 12 (04): : 321 - 321