Bilateral Breast Irradiation Using Hybrid Volumetric Modulated Arc Therapy (h-VMAT) Technique: A Planning Case Report

被引:10
|
作者
Subramanian, Sitaraman Balaji [1 ]
Balaji, Karunakaran [1 ]
Thirunavukarasu, Moorthi [1 ]
Premkumar, Sumana [1 ]
机构
[1] Global Hosp, Dept Radiat Oncol, Madras, Tamil Nadu, India
来源
CUREUS | 2016年 / 8卷 / 12期
关键词
bilateral breast cancer; vmat; hybrid vmat;
D O I
10.7759/cureus.914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this planning case report is to share the perceived dosimetric benefits of innovative hybrid volumetric modulated arc therapy (h-VMAT) for bilateral breast cancer radiotherapy in two patients with synchronous bilateral breast cancer. Two patients with early bilateral breast cancer after breast conservation surgery and adjuvant chemotherapy were planned for bilateral breast radiotherapy. On the planning computed tomography (CT) dataset, bilateral breast planning treatment volume (PTV) and organs at risk (OARs) were delineated using standard guidelines. Using the same structure set, volumetric modulated arc therapy (VMAT) and h-VMAT plans were generated and compared dosimetrically. The h-VMAT showed comparable target coverage, conformity and homogeneity while sparing of both lungs and heart were better. The dose to heart was reduced with h-VMAT, with a V-25Gy and V-5Gy of 3.2 & 22.3% for h-VMAT versus 11.6 & 84.9% for the VMAT plan. Similarly, the dose to the total lung was better in h-VMAT with a V-20Gy and V-5Gy of 12.1 & 46.2 versus 19.9 & 83.3% for VMAT. Overall the results indicate a better sparing of lung and heart at low doses with h-VMAT. Long-term clinical follow-up will give us more insight about the dosimetric benefits of these innovative techniques.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Optimisation of user-selectable volumetric modulated arc therapy (VMAT) planning parameters: VMAT arcs for prostate and head-and-neck cancers
    Murtaza, Ghulam
    Gillani, Zaheer Abbas
    Mehmood, Shahid
    Rehman, Jalil Ur
    Khan, Ehsan Ullah
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (04) : 1093 - 1099
  • [32] Predicting deliverability of volumetric-modulated arc therapy (VMAT) plans using aperture complexity analysis
    Younge, Kelly C.
    Roberts, Don
    Janes, Lindsay A.
    Anderson, Carlos
    Moran, Jean M.
    Matuszak, Martha M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 124 - 131
  • [33] Fully automated volumetric modulated arc therapy technique for radiation therapy of locally advanced breast cancer
    Livia Marrazzo
    Laura Redapi
    Roberto Pellegrini
    Peter Voet
    Icro Meattini
    Chiara Arilli
    Silvia Calusi
    Marta Casati
    Deborah Chilà
    Antonella Compagnucci
    Cinzia Talamonti
    Margherita Zani
    Lorenzo Livi
    Stefania Pallotta
    Radiation Oncology, 18
  • [34] On a single isocenter volumetric modulated arc therapy SRS planning technique for multiple brain metastases
    Hardcastle, Nicholas
    Tome, Wolfgang A.
    JOURNAL OF RADIOSURGERY AND SBRT, 2012, 2 (01): : 1 - 9
  • [35] Simultaneous delivery time and aperture shape optimization for the volumetric-modulated arc therapy (VMAT) treatment planning problem
    Mahnam, Mehdi
    Gendreau, Michel
    Lahrichi, Nadia
    Rousseau, Louis-Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14) : 5589 - 5611
  • [36] Comparison of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) Plannings for the Treatment of Left Sided Breast and Regional Lymphatic Tissue
    Hossain, Sabbir
    Islam, Mohammad R.
    Lee, Gabriel
    Higby, Christine
    Ahmad, Salahuddin
    Algan, Ozer
    MEDICAL PHYSICS: Fourteenth Mexican Symposium on Medical Physics, 2016, 1747
  • [37] Fully automated volumetric modulated arc therapy technique for radiation therapy of locally advanced breast cancer
    Marrazzo, Livia
    Redapi, Laura
    Pellegrini, Roberto
    Voet, Peter
    Meattini, Icro
    Arilli, Chiara
    Calusi, Silvia
    Casati, Marta
    Chila, Deborah
    Compagnucci, Antonella
    Talamonti, Cinzia
    Zani, Margherita
    Livi, Lorenzo
    Pallotta, Stefania
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [38] Dosimetric advantages of volumetric modulated arc therapy (VMAT) with deep inspiration breath hold (DIBH) technique in Halcyon Linac for left breast cancer treatment
    Cheung, Alex Pui-yin
    Lei, Michelle Man-i
    Lee, Sau-sing
    Hung, Wai-ki
    Chiu, Chun-wang
    Qiu, Xi-bin
    Chau, Ricky Ming-chun
    MEDICAL DOSIMETRY, 2022, 47 (03) : 288 - 294
  • [39] Dosimetric Comparision of Coplanar versus Noncoplanar Volumetric Modulated Arc Therapy for Treatment of Bilateral Breast Cancers
    Bharati, Avinav
    Rath, Satyajeet
    Khurana, Rohini
    Rastogi, Madhup
    Mandal, Susama R.
    Gandhi, Ajeet Kumar
    Hadi, Rahat
    Srivastava, Anoop K.
    Mishra, Surendra Prasad
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 252 - 258
  • [40] Dosimetric comparison between volumetric-modulated arc therapy and a hybrid volumetric-modulated arc therapy and segmented field-in-field technique for post-mastectomy chest wall and regional lymph node irradiation
    Lang, Karen
    Loritz, Brianne
    Schwartz, Adam
    Hunzeker, Ashley
    Lenards, Nishele
    Culp, Lee
    Finley, Randi
    Corbin, Kimberly S.
    MEDICAL DOSIMETRY, 2020, 45 (01) : 108 - 108