Bilateral Breast Irradiation Using Hybrid Volumetric Modulated Arc Therapy (h-VMAT) Technique: A Planning Case Report

被引:10
|
作者
Subramanian, Sitaraman Balaji [1 ]
Balaji, Karunakaran [1 ]
Thirunavukarasu, Moorthi [1 ]
Premkumar, Sumana [1 ]
机构
[1] Global Hosp, Dept Radiat Oncol, Madras, Tamil Nadu, India
来源
CUREUS | 2016年 / 8卷 / 12期
关键词
bilateral breast cancer; vmat; hybrid vmat;
D O I
10.7759/cureus.914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this planning case report is to share the perceived dosimetric benefits of innovative hybrid volumetric modulated arc therapy (h-VMAT) for bilateral breast cancer radiotherapy in two patients with synchronous bilateral breast cancer. Two patients with early bilateral breast cancer after breast conservation surgery and adjuvant chemotherapy were planned for bilateral breast radiotherapy. On the planning computed tomography (CT) dataset, bilateral breast planning treatment volume (PTV) and organs at risk (OARs) were delineated using standard guidelines. Using the same structure set, volumetric modulated arc therapy (VMAT) and h-VMAT plans were generated and compared dosimetrically. The h-VMAT showed comparable target coverage, conformity and homogeneity while sparing of both lungs and heart were better. The dose to heart was reduced with h-VMAT, with a V-25Gy and V-5Gy of 3.2 & 22.3% for h-VMAT versus 11.6 & 84.9% for the VMAT plan. Similarly, the dose to the total lung was better in h-VMAT with a V-20Gy and V-5Gy of 12.1 & 46.2 versus 19.9 & 83.3% for VMAT. Overall the results indicate a better sparing of lung and heart at low doses with h-VMAT. Long-term clinical follow-up will give us more insight about the dosimetric benefits of these innovative techniques.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Automatic planning of the lower extremities for total marrow irradiation using volumetric modulated arc therapy
    Nicola Lambri
    Damiano Dei
    Victor Hernandez
    Isabella Castiglioni
    Elena Clerici
    Leonardo Crespi
    Chiara De Philippis
    Daniele Loiacono
    Pierina Navarria
    Giacomo Reggiori
    Roberto Rusconi
    Stefano Tomatis
    Stefania Bramanti
    Marta Scorsetti
    Pietro Mancosu
    Strahlentherapie und Onkologie, 2023, 199 : 412 - 419
  • [22] Effective heart-sparing whole lung irradiation using volumetric modulated arc therapy: a case report
    Suzuki, Gen
    Ogata, Toshiyuki
    Aibe, Norihiro
    Yamazaki, Hideya
    Yagyu, Shigeki
    Iehara, Tomoko
    Hosoi, Hajime
    Yamada, Kei
    JOURNAL OF MEDICAL CASE REPORTS, 2019, 13 (01)
  • [23] Efficacy, safety, and feasibility of volumetric modulated arc therapy for synchronous bilateral breast cancer management
    Quesada, Stanislas
    Fenoglietto, Pascal
    Gourgou, Sophie
    Lemanski, Claire
    Draghici, Roxana
    Ailleres, Norbert
    Prunaretty, Jessica
    Azria, David
    Bourgier, Celine
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [24] Usability and necessity of a novel hybrid radiation therapy technique based on volumetric modulated arc therapy (VMAT) in stage III lung cancer treatment
    Ko, Young Eun
    Ahn, Seung Do
    Je, Hyoung Uk
    RADIATION PHYSICS AND CHEMISTRY, 2022, 195
  • [25] Radiosurgery treatment planning using conformal arc informed volumetric modulated arc therapy
    Giles, William M.
    Cullom, Edward T.
    Laryea, Obed A. -O.
    Nobah, Ahmad
    Alves, Victor G. L.
    Yin, Fang-Fang
    Kirkpatrick, John P.
    Adamson, Justus D.
    MEDICAL DOSIMETRY, 2021, 46 (01) : 3 - 12
  • [26] Hybrid volumetric modulated arc therapy for chest wall irradiation: For a good plan, get the right mixture
    Balaji, Karunakaran
    Yadav, Poonam
    BalajiSubramanian, Sitaraman
    Radha, Chandrasekaran Anu
    Ramasubramanian, Velayudham
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 : 86 - 92
  • [27] Single-Arc Volumetric Modulated Arc Therapy Planning for Left Breast Cancer and Regional Nodes
    Sakumi, Akira
    Shiraishi, Kenshiro
    Onoe, Tsuyoshi
    Yamamoto, Kentaro
    Haga, Akihiro
    Yoda, Kiyoshi
    Ohtomo, Kuni
    Nakagawa, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (01) : 151 - 153
  • [28] Dosimetric comparison between volumetric-modulated arc therapy and a hybrid volumetric-modulated arc therapy and segmented field-in-field technique for postmastectomy chest wall and regional lymph node irradiation
    Lang, Karen
    Loritz, Brianne
    Schwartz, Adam
    Hunzeker, Ashley
    Lenards, Nishele
    Culp, Lee
    Finley, Randi
    Corbin, Kimberly S.
    MEDICAL DOSIMETRY, 2020, 45 (02) : 121 - 127
  • [29] Using branch-and-price to determine optimal treatment plans for volumetric modulated arc therapy (VMAT)
    Dursun, Pinar
    Taskin, Z. Caner
    Altinel, I. Kuban
    COMPUTERS & OPERATIONS RESEARCH, 2019, 110 : 1 - 17
  • [30] Dosimetry and efficiency comparison of knowledge-based and manual planning using volumetric modulated arc therapy for craniospinal irradiation
    Tsai, Wei-Ta
    Hsieh, Hui-Ling
    Hung, Shih-Kai
    Zeng, Chi-Fu
    Lee, Ming-Fen
    Lin, Po-Hao
    Lin, Chia-Yi
    Li, Wei-Chih
    Chiou, Wen-Yen
    Wu, Tung-Hsin
    RADIOLOGY AND ONCOLOGY, 2024, 58 (02) : 289 - 299