A SUCCESSFUL COMPUTERIZED PROTOCOL FOR CLINICAL MANAGEMENT OF PRESSURE CONTROL INVERSE RATIO VENTILATION IN ARDS PATIENTS

被引:65
作者
EAST, TD
BOHM, SH
WALLACE, CJ
CLEMMER, TP
WEAVER, LK
ORME, JF
MORRIS, AH
机构
[1] LATTER DAY ST HOSP,DEPT INTERNAL MED,DIV CRIT CARE,SALT LAKE CITY,UT 84143
[2] UNIV UTAH,DEPT BIOENGN,SALT LAKE CITY,UT 84112
[3] UNIV UTAH,MED CTR,DEPT ANESTHESIOL,SALT LAKE CITY,UT 84112
关键词
D O I
10.1378/chest.101.3.697
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We have developed a computerized protocol that provides a systematic approach for management of pressure control-inverse ratio ventilation (PCIRV). The protocols were used for 1,466 h in ten around-the-clock PCIRV evaluations on seven patients with severe adult respiratory distress syndrome (ARDS). Patient therapy was controlled by protocol 95 percent of the time (1,396 of 1,466 h) and 90 percent of the protocol instructions (1,937 of 2,158) were followed by the clinical staff. Of the 221 protocol instructions, 88 (39 percent) not followed were due to invalid PEEPi measurements. Compared with preceding values during CPPV, the expired minute ventilation was reduced by 27 percent during PCIRV while maintaining a pH that was not clinically different (mean difference in pH = 0.02). There was no difference in the PaO2, PEEPi, or the FI(O2) between PCIRV and CPPV. The PEEP setting was reduced by 33 percent from 9 +/- 0.05 to 6 +/- 0.6 and the I:E ratio increased from 0.64 +/- 0.04 to 2.3 +/- 0.10. Peak airway pressure was reduced by 24 percent (from 59 +/- 1.5 to 45 +/- 0.6) and mean airway pressure increased by 27 percent (from 22 +/- 0.8 to 28 +/- 0.6) in PCIRV. Right atrial and pulmonary artery pressures were higher and cardiac output lower in PCIRV but blood pressure was unchanged. The success of this protocol has demonstrated the feasibility of using PEEPi as a primary control variable for oxygenation. This computerized PCIRV protocol should make the future use of PCIRV less mystifying, simpler, and more systematic.
引用
收藏
页码:697 / 710
页数:14
相关论文
共 33 条
  • [1] CARDIORESPIRATORY EFFECTS OF PRESSURE CONTROLLED INVERSE RATIO VENTILATION IN SEVERE RESPIRATORY-FAILURE
    ABRAHAM, E
    YOSHIHARA, G
    [J]. CHEST, 1989, 96 (06) : 1356 - 1359
  • [2] ALBELDA SM, 1983, AM REV RESPIR DIS, V127, P360
  • [3] ANDERSEN JB, 1987, INTENSIVE CARE WORLD, V4, P21
  • [4] BAUM M, 1980, ANAESTHESIST, V29, P592
  • [5] BENSON M S, 1988, Respiratory Care, V33, P557
  • [6] BROWN D G, 1986, Respiratory Care, V31, P1069
  • [7] EFFECT OF INTRINSIC POSITIVE END-EXPIRATORY PRESSURE ON RESPIRATORY COMPLIANCE
    CAVIEDES, I
    BENITO, S
    MANCEBO, J
    NET, A
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (11) : 947 - 949
  • [8] CHURG A, 1983, AM REV RESPIR DIS, V127, P117, DOI 10.1164/arrd.1983.127.1.117
  • [9] COLE AGH, 1984, INTENS CARE MED, V10, P227
  • [10] INVERSE RATIO VENTILATION PEEP IN DISGUISE
    DUNCAN, SR
    RIZK, NW
    RAFFIN, TA
    [J]. CHEST, 1987, 92 (03) : 390 - 392