Effect of High-dose Biotin on Thyroid Function Tests: Case Report and Literature Review

被引:14
作者
Ardabilygazir, Arash [1 ]
Afshariyamchlou, Sonia [1 ]
Mir, Danial [2 ]
Sachmechi, Issac [3 ]
机构
[1] Mt Sinai Queens Hosp Ctr, Icahn Sch Med, Med, Jamaica, NY USA
[2] Mt Sinai Queens Hosp Ctr, Icahn Sch Med, Med, Great Neck, NY USA
[3] Queens Hosp New York, Mt Sinai Icahn Sch Med, Internal Med, Flushing, NY USA
来源
CUREUS | 2018年 / 10卷 / 06期
关键词
high dose biotin; thyroid function tests; multiple sclerosis; graves disease; hyperthyroidism; biotin-streptavidin immunoassay;
D O I
10.7759/cureus.2845
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biotin is a readily available supplement that is part of the B-complex vitamins. It is an essential co-factor for five carboxylases involved in fatty acid synthesis and energy production. The recommended daily intake (RDI) of biotin ranges from 30 to 70 mcg per day. At high doses (10,000 times RDI), biotin improves clinical outcomes and quality of life in patients with progressive multiple sclerosis (MS). It has been reported to cause interference in immunoassays resulting in abnormal thyroid function tests. Hereby we are describing the case of a patient having MS who was on high-dose biotin, seen in the clinic for a follow-up visit with thyroid function tests suggestive of Graves' disease with no signs and symptoms of hyperthyroidism and completely normal physical examination. In the case we have described, the laboratory measurements suggestive of thyrotoxicosis were attributed to interference of the patient's high-dose biotin treatment with the biotin-streptavidin chemistry of the immunoassays. We observed normalization of the thyroid stimulating hormone (TSH) and free T4 measurements when the patient withheld biotin for a week. As our case illustrates, early consideration of biotin interference minimizes unnecessary repeat laboratory studies. As trials in MS are progressing, we expect to see more patients on high-dose biotin treatment with spurious laboratory measurements. Therefore, we advise careful history taking and close communication with the laboratory when the clinical picture does not match with the laboratory results.
引用
收藏
页数:5
相关论文
共 8 条
  • [1] Biotin interference on immunoassay methods: sporadic cases or hidden epidemic?
    Clerico, Aldo
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (06) : 777 - 779
  • [2] DIAMANDIS EP, 1991, CLIN CHEM, V37, P625
  • [3] Biotin interference on TSH and free thyroid hormone measurement
    Kwok, Jeffrey Sung-Shing
    Chan, Iris Hiu-Shuen
    Chan, Michael Ho-Ming
    [J]. PATHOLOGY, 2012, 44 (03) : 278 - 280
  • [4] Minkovsky Alissa, 2016, AACE Clin Case Rep, V2, pe370
  • [5] Biochemical Hyperthyroidism in a Newborn Baby Caused by Assay Interaction from Biotin Intake
    Pedersen, Inge Bulow
    Laurberg, Peter
    [J]. EUROPEAN THYROID JOURNAL, 2016, 5 (03) : 212 - 215
  • [6] High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference
    Piketty, Marie-Liesse
    Prie, Dominique
    Sedel, Frederic
    Bernard, Delphine
    Hercend, Claude
    Chanson, Philippe
    Souberbielle, Jean-Claude
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (06) : 817 - 825
  • [7] High doses of biotin in chronic progressive multiple sclerosis: A pilot study
    Sedel, Frederic
    Papeix, Caroline
    Bellanger, Agnes
    Touitou, Valerie
    Lebrun-Frenay, Christine
    Galanaud, Damien
    Gout, Olivier
    Lyon-Caen, Olivier
    Tourbah, Ayman
    [J]. MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2015, 4 (02) : 159 - 169
  • [8] Positive and negative interference in immunoassays following biotin ingestion: a pharmacokinetic study
    Wijeratne, Nilika G.
    Doery, James C. G.
    Lu, Zhong X.
    [J]. PATHOLOGY, 2012, 44 (07) : 674 - 675