Artificial urinary sphincters for male stress urinary incontinence: current perspectives

被引:35
作者
Cordon, Billy H. [1 ]
Singla, Nirmish [1 ]
Singla, Ajay K. [2 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Urol, Dallas, TX 75390 USA
[2] Univ Toledo, Coll Med, Dept Urol, 3000 Arlington Ave,MS 1091, Toledo, OH 43614 USA
关键词
artificial urinary sphincter; stress urinary incontinence; post prostatectomy incontinence; prostheses and implants; review;
D O I
10.2147/MDER.S93637
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The artificial urinary sphincter (AUS), which has evolved over many years, has become a safe and reliable treatment for stress urinary incontinence and is currently the gold standard. After 4 decades of existence, there is substantial experience with the AUS. Today AUS is most commonly placed for postprostatectomy stress urinary incontinence. Only a small proportion of urologists routinely place AUS. In a survey in 2005, only 4% of urologists were considered high-volume AUS implanters, performing >20 per year. Globally, similar to 11,500 AUSs are placed annually. Over 400 articles have been published regarding the outcomes of AUS, with a wide variance in success rates ranging from 61% to 100%. Generally speaking, the AUS has good long-term outcomes, with social continence rates of similar to 79% and high patient satisfaction usually between 80% and 90%. Despite good outcomes, a substantial proportion of patients, generally similar to 25%, will require revision surgery, with the rate of revision increasing with time. Complications requiring revision include infection, urethral atrophy, erosion, and mechanical failure. Most infections are gram-positive skin flora. Urethral atrophy and erosion lie on a spectrum resulting from the same problem, constant urethral compression. However, these two complications are managed differently. Mechanical failure is usually a late complication occurring on average later than infection, atrophy, or erosions. Various techniques may be used during revisions, including cuff relocation, downsizing, transcorporal cuff placement, or tandem cuff placement. Patient satisfaction does not appear to be affected by the need for revision as long as continence is restored. Additionally, AUS following prior sling surgery has comparable outcomes to primary AUS placement. Several new inventions are on the horizon, although none have been approved for use in the US at this point.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 79 条
[1]   Transcorporal artificial urinary sphincter placement for incontinence in high-risk patients after treatment of prostate cancer [J].
Aaronson, David S. ;
Elliott, Sean P. ;
McAninch, Jack W. .
UROLOGY, 2008, 72 (04) :825-827
[2]   Salvage therapy with artificial urinary sphincter after Advance™ male sling failure for post-prostatectomy incontinence: A first clinical experience [J].
Abdou, A. ;
Cornu, J. -N. ;
Sebe, P. ;
Ciofu, C. ;
Peyrat, L. ;
Cussenot, O. ;
Haab, F. .
PROGRES EN UROLOGIE, 2012, 22 (11) :650-656
[3]   Complications following artificial urinary sphincter placement after radical prostatectomy and radiotherapy: a meta-analysis [J].
Bates, Anthony S. ;
Martin, Richard M. ;
Terry, Tim R. .
BJU INTERNATIONAL, 2015, 116 (04) :623-633
[4]   Artificial Urinary Sphincter: Report of the 2015 Consensus Conference [J].
Biardeau, X. ;
Aharony, S. ;
Campeau, L. ;
Corcos, J. .
NEUROUROLOGY AND URODYNAMICS, 2016, 35 :S8-S24
[5]   Treatment of male urinary incontinence by artificial urinary sphincter with intracavernous cuff [J].
Blah, M. ;
Caremel, R. ;
Sibert, L. ;
Bugel, H. ;
Grise, P. .
PROGRES EN UROLOGIE, 2008, 18 (02) :114-119
[6]   Long-term results of the treatment of urinary incontinence with bulbar implantation of artificial urinary sphincter in men: A single-center experience [J].
Bordenave, M. ;
Roupret, M. ;
Taksin, L. ;
Parra, J. ;
Cour, F. ;
Richard, F. ;
Bitker, M. -O ;
Chartier-Kastler, E. .
PROGRES EN UROLOGIE, 2011, 21 (04) :277-282
[7]   Risk Factors for Erosion of Artificial Urinary Sphincters: A Multicenter Prospective Study [J].
Brant, William O. ;
Erickson, Bradley A. ;
Elliott, Sean P. ;
Powell, Christopher ;
Alsikafi, Nejd ;
McClung, Christopher ;
Myers, Jeremy B. ;
Voelzke, Bryan B. ;
Smith, Thomas G., III ;
Broghammer, Joshua A. .
UROLOGY, 2014, 84 (04) :934-938
[8]   USE OF A DOUBLE CUFF AMS800 URINARY SPHINCTER FOR SEVERE STRESS-INCONTINENCE [J].
BRITO, CG ;
MULCAHY, JJ ;
MITCHELL, ME ;
ADAMS, MC .
JOURNAL OF UROLOGY, 1993, 149 (02) :283-285
[9]   Foley or Fix: A Comparative Analysis of Reparative Procedures at the Time of Explantation of Artificial Urinary Sphincter for Cuff Erosion [J].
Chertack, Nathan ;
Chaparala, Hemant ;
Angermeier, Kenneth W. ;
Montague, Drogo K. ;
Wood, Hadley M. .
UROLOGY, 2016, 90 :173-178
[10]   Treatment of Recurrent Urinary Incontinence After Artificial Urinary Sphincter Placement Using the AdVance Male Sling [J].
Christine, Brian ;
Knoll, L. Dean .
UROLOGY, 2010, 76 (06) :1321-1324