X-RAY POSITION-SENSITIVE DETECTORS .6. ON SOME FACTORS CONTROLLING HIGH-ACCURACY MEASUREMENTS OF X-RAY QUANTA POSITIONS WITH MULTIWIRE PROPORTIONAL CHAMBERS

被引:11
作者
CHARPAK, G
SAULI, F
KAHN, R
机构
[1] UNIV PARIS 11,CNRS,UTILISAT RAYONNEMENT ELECTROMAGNET LAB,F-91405 ORSAY,FRANCE
[2] UNIV PARIS 7,PHYSICOCHIM STRUCT LAB,F-75221 PARIS 05,FRANCE
来源
NUCLEAR INSTRUMENTS & METHODS | 1978年 / 152卷 / 01期
关键词
D O I
10.1016/0029-554X(78)90262-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Multiwire proportional chambers (MWPC) may provide a useful tool for dealing with many problems concerned with the localization of X-ray quanta. The accuracy in the determination of the spatial coordinates of a single quantum in a chamber is controlled by several factors: • - the spatial extension of the secondary electrons produced by the absorption of the quantum; • - the mean free path of the secondary X-rays emitted by the absorbing atom; • - the chamber parameters: detection thickness and wire spacing; • - the read-out method. At LURE, we are trying to build large-size detectors, having a large angular aperture (≈ 90°), accuracies better than 1 mm (fwhm), high counting-rate capabilities (≈ 1 MHz), and high efficiencies (≈ 100% at 8 keV); in this paper we will discuss some problems encountered in this enterprise. © 1978.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 15 条
[1]   SPATIAL-RESOLUTION IN A XENON FILLED MWPC X-RAY IMAGING DETECTOR - COMPUTING PHYSICS APPROACH [J].
BATEMAN, JE ;
WATERS, MW ;
JONES, RE .
NUCLEAR INSTRUMENTS & METHODS, 1976, 135 (02) :235-249
[2]  
BERGSTROM I, 1968, AUGER EFFECT ALPHA B, P1526
[3]   DESIGN AND PROPERTIES OF POSITION-SENSITIVE PROPORTIONAL-COUNTERS USING RESISTANCE-CAPACITANCE POSITION ENCODING [J].
BORKOWSKI, CJ ;
KOPP, MK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (08) :951-962
[4]   HIGH-ACCURACY, BIDIMENSIONAL READOUT OF PROPORTIONAL CHAMBERS WITH SHORT RESOLUTION TIMES [J].
BRESKIN, A ;
CHARPAK, G ;
DEMIERRE, C ;
MAJEWSKI, S ;
POLICARPO, A ;
SAULI, F ;
SANTIARD, JC .
NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (01) :29-39
[5]   SOME DEVELOPMENTS IN OPERATION OF MULTIWIRE PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
RAHM, D ;
STEINER, H .
NUCLEAR INSTRUMENTS & METHODS, 1970, 80 (01) :13-+
[6]   PROGRESS IN HIGH-ACCURACY PROPORTIONAL CHAMBERS [J].
CHARPAK, G ;
PETERSEN, G ;
POLICARPO, A ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS, 1978, 148 (03) :471-482
[7]  
CHARPAK G, 1974, NUCL INSTRUM METHODS, V122, P1307
[8]  
CHARPAK G, 1973, CERN7311
[9]   MULTIWIRE PROPORTIONAL CHAMBER AS AN AREA DETECTOR FOR PROTEIN CRYSTALLOGRAPHY [J].
CORK, C ;
FEHR, D ;
HAMLIN, R ;
VERNON, W ;
XUONG, NH ;
PEREZMEN.V .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1974, 7 (JUN1) :319-323
[10]  
Grove R., 1970, Nuclear Instruments and Methods, V89, P257, DOI 10.1016/0029-554X(70)90833-5