SEQUENCING OF PEPTIDES IN A TIME-OF-FLIGHT MASS-SPECTROMETER - EVALUATION OF POSTSOURCE DECAY FOLLOWING MATRIX-ASSISTED LASER-DESORPTION IONIZATION (MALDI)

被引:267
作者
KAUFMANN, R
KIRSCH, D
SPENGLER, B
机构
[1] Institute of Laser Medicine, Heinrich-Heine-University, D-4000 Duesseldorf
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1994年 / 131卷
关键词
MATRIX-ASSISTED LASER DESORPTION IONIZATION; POSTSOURCE DECAY; COLLISIONALLY-ACTIVATED DISSOCIATION; REFLECTRON; PEPTIDES;
D O I
10.1016/0168-1176(93)03876-N
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In matrix assisted laser desorption ionisation (MALDI) a large fraction of analyte ions undergo postsource decay (PSD) during flight in the field free drift path. By means of a modified two-stage reflectron, daughter ion time-of-flight spectra of medium sized linear peptides (up to 2800 u) were recorded containing full sequence information. Precision, accuracy and mass resolution of fragment ions were almost as good as obtained in high energy CAD studies performed in four-sector instruments. Instrumental sensitivity was better by at least one order of magnitude. In reflectron time-of-flight mass spectrometry (RETOF-MS) the cleavage pattern of PSD products is different from that obtained by high energy and low energy CAD. In our instrument, conditions which were energetically comparable to high energy and low energy CAD could easily and comparatively be studied in the same experiment by varying instrumental parameters. Activation mechanisms of PSD were found to be largely determined by collisional events (ion/neutral) induced by the acceleration field during early plume expansion. Future potentials of PSD analysis after MALDI are discussed.
引用
收藏
页码:355 / 385
页数:31
相关论文
共 44 条
[1]   CHARGE-REMOTE FRAGMENTATIONS - ANALYTICAL APPLICATIONS AND FUNDAMENTAL-STUDIES [J].
ADAMS, J .
MASS SPECTROMETRY REVIEWS, 1990, 9 (02) :141-186
[2]   COLLISION-INDUCED DISSOCIATION OF PEPTIDE IONS .3. COMPARISON OF RESULTS OBTAINED USING SECTOR-QUADRUPOLE HYBRIDS WITH THOSE FROM TANDEM DOUBLE-FOCUSING INSTRUMENTS [J].
ALEXANDER, AJ ;
THIBAULT, P ;
BOYD, RK ;
CURTIS, JM ;
RINEHART, KL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (02) :107-134
[3]  
BARINAGA CJ, 1989, RAPID COMMUN MASS SP, V3, P160
[4]   TANDEM MASS-SPECTROMETRY OF PEPTIDES USING HYBRID AND 4-SECTOR INSTRUMENTS - A COMPARATIVE-STUDY [J].
BEAN, MF ;
CARR, SA ;
THORNE, GC ;
REILLY, MH ;
GASKELL, SJ .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1473-1481
[5]  
Beavis R C, 1989, Rapid Commun Mass Spectrom, V3, P432, DOI 10.1002/rcm.1290031207
[6]   VELOCITY DISTRIBUTIONS OF INTACT HIGH MASS POLYPEPTIDE MOLECULE IONS PRODUCED BY MATRIX ASSISTED LASER DESORPTION [J].
BEAVIS, RC ;
CHAIT, BT .
CHEMICAL PHYSICS LETTERS, 1991, 181 (05) :479-484
[7]   REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETRY AND LASER EXCITATION FOR THE ANALYSIS OF NEUTRALS, IONIZED MOLECULES AND SECONDARY FRAGMENTS [J].
BOESL, U ;
WEINKAUF, R ;
SCHLAG, EW .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1992, 112 (2-3) :121-166
[8]   MULTI-PHOTON MASS-SPECTROMETRY OF METASTABLES - DIRECT OBSERVATION OF DECAY IN A HIGH-RESOLUTION TIME-OF-FLIGHT INSTRUMENT [J].
BOESL, U ;
NEUSSER, HJ ;
WEINKAUF, R ;
SCHLAG, EW .
JOURNAL OF PHYSICAL CHEMISTRY, 1982, 86 (25) :4857-4863
[9]   COMPARISON OF HELIUM AND ARGON AS COLLISION GASES IN THE HIGH-ENERGY COLLISION-INDUCED DECOMPOSITION OF MH+ IONS OF PEPTIDES [J].
BORDASNAGY, J ;
DESPEYROUX, D ;
JENNINGS, KR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (05) :502-514
[10]   TANDEM MASS-SPECTROMETRY OF PEPTIDES USING A MAGNETIC-SECTOR QUADRUPOLE HYBRID - THE CASE FOR HIGHER COLLISION ENERGY AND HIGHER RADIOFREQUENCY POWER [J].
BRADLEY, CD ;
CURTIS, JM ;
DERRICK, PJ ;
WRIGHT, B .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2628-2635