CORONARY STENTING WITH POLYMER-COATED AND UNCOATED SELF-EXPANDING ENDOPROSTHESES IN PIGS

被引:33
作者
VANDERGIESSEN, WJ
VANBEUSEKOM, HMM
VANHOUTEN, CD
VANWOERKENS, LJ
VERDOUW, PD
SERRUYS, PW
机构
[1] Thoraxcenter, Department of Cardiology, Erasmus University Rotterdam
关键词
CORONARY ANGIOPLASTY; GRAFTS AND PROSTHESES; QUANTITATIVE ANGIOGRAPHY; HISTOLOGY; IMMUNOCYTOCHEMISTRY; STENTS; ANTITHROMBOTIC TREATMENT; PIGS;
D O I
10.1097/00019501-199207000-00014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Preliminary clinical reports suggest that metallic stents are thrombogenic during the first days to weeks after implantation but that restenosis rates after this period may be reduced. Methods: We investigated the angiographic patency and histologically measured neointimal hyperplasia of 48 uncoated self-expanding, stainless steel mesh stents (Wallstent, Schneider [Europe AG, Bulach, Switzerland) placed in normal coronary arteries of three groups of eight pigs that received postprocedure aspirin (ASA, group B), acenocoumarol (group C), or no medication (group A). The results were compared with those obtained in a fourth group of eight pigs (group D) receiving 15 polymer-coated (BioGold, PlasmaCarb Inc., Bedford, NH, USA) Wallstent stents, which are designed to reduce thrombogenicity without additional medication. After 1, 4, and 12 weeks, angiography was repeated. After the last angiogram the coronary arteries were pressure-fixated followed by light microscopy, immunocytochemistry, and electron microscopic examination. Results: Group A showed a 38% thrombotic occlusion rate within 1 week, which was prevented by acenocoumarol or polymer coating, but not by ASA. Histologic analysis showed no difference in the thickness of neointimal hyperplasia between the groups (median values: 134, 101, 143 and 113-mu-m for groups A, B, C, and D, respectively). Polymer coating did not induce an inflammatory reaction. Conclusions: Acenocoumarol and the polymer coating protected against early thrombotic occlusion of stainless steel self-expanding stents, but neointimal hyperplasia was not affected by preventive measures against stent thrombosis.
引用
收藏
页码:631 / 640
页数:10
相关论文
共 49 条
  • [1] LECTIN HISTOCHEMISTRY OF MAMMALIAN ENDOTHELIUM
    ALROY, J
    GOYAL, V
    SKUTELSKY, E
    [J]. HISTOCHEMISTRY, 1987, 86 (06) : 603 - 607
  • [2] ANDERSON HV, 1985, AM J CARDIOL, V56, P712
  • [3] BEATT K J, 1989, Journal of the American College of Cardiology, V13, p224A
  • [4] RESTENOSIS AFTER CORONARY ANGIOPLASTY - THE PARADOX OF INCREASED LUMEN DIAMETER AND RESTENOSIS
    BEATT, KJ
    SERRUYS, PW
    LUIJTEN, HE
    RENSING, BJ
    SURYAPRANATA, H
    DEFEYTER, P
    VANDENBRAND, M
    LAARMAN, GJ
    ROELANDT, J
    VANES, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 258 - 266
  • [5] ENDOTHELIAL INTEGRITY AND VIABILITY IN AORTA OF NORMAL RABBIT AND RAT AS EVALUATED WITH DYE EXCLUSION TESTS AND INTERFERENCE CONTRAST MICROSCOPY
    BJORKERUD, S
    BONDJERS, G
    [J]. ATHEROSCLEROSIS, 1972, 15 (03) : 285 - +
  • [6] MEDICAL APPROACHES TO PREVENTION OF RESTENOSIS AFTER CORONARY ANGIOPLASTY
    BLACKSHEAR, JL
    OCALLAGHAN, WG
    CALIFF, RM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (04) : 834 - 848
  • [7] IN-HOSPITAL MORBIDITY AND MORTALITY IN PATIENTS UNDERGOING ELECTIVE CORONARY ANGIOPLASTY
    BREDLAU, CE
    ROUBIN, GS
    LEIMGRUBER, PP
    DOUGLAS, JS
    KING, SB
    GRUENTZIG, AR
    [J]. CIRCULATION, 1985, 72 (05) : 1044 - 1052
  • [8] THE IMPORTANCE OF ADEQUATE ANTICOAGULATION TO PREVENT EARLY THROMBOSIS AFTER STENTING OF STENOSED VENOUS BYPASS GRAFTS
    BUCX, JJJ
    DESCHEERDER, I
    BEATT, K
    VANDENBRAND, M
    SURYAPRANATA, H
    DEFEYTER, PJ
    SERRUYS, PW
    [J]. AMERICAN HEART JOURNAL, 1991, 121 (05) : 1389 - 1396
  • [9] Carrel A, 1912, SURG GYNECOL OBSTET, V15, P245
  • [10] Chesebro JH, 1989, CIRCULATION S2, V80, pII