Is a composite reference standard (CRS) an alternative to culture in assessment and validation of a single tube nested in-house PCR for TB diagnosis?

被引:7
作者
Deshmukh, Minal [1 ]
Nikam, Chaitali [1 ]
Ragte, Trupti [1 ]
Shetty, Anjali [1 ]
Rodrigues, Camilla [1 ]
机构
[1] P D Hinduja Natl Hosp & Med Res Ctr, Dept Microbiol & Res, Bombay 400016, Maharashtra, India
来源
EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS | 2013年 / 62卷 / 04期
关键词
CRS; Single-tube nested PCR; TB diagnosis; Validation; IS6110; M; tuberculosis;
D O I
10.1016/j.ejcdt.2013.09.014
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Delay in diagnosis of paucibacillary extra pulmonary tuberculosis (TB) and of smear negative TB has hampered the efforts taken by Control Programs to curb its spread. Better efforts to control spread of TB require more accurate and rapid diagnostic test. Aims: To facilitate early diagnosis of TB directly from clinical specimens, we have standardized and validated the use of a single tube in-house nested PCR in comparison against culture and composite reference standard (CRS). Methods: Single tube nested PCR was performed using primers targeting Insertion Sequence (IS) 6110 of Mycobacterium tuberculosis complex. Microbiological techniques includes AFB smear microscopy, and cultivation on solid egg-based medium (Lowenstein-Jensen [LJ]) and on liquid culture medium using BACTEC MGIT 960 system, BD Microbiology Systems. Results: The sensitivity and specificity of PCR against culture was observed to be 89.7% [95% CI: 84.1-93.5] and 73.1% [95% CI: 67.4-78.1] respectively and that against CRS criteria was 80.2% [95% CI: 75.1-84.5] and 97.1% [95% CI: 92.9-98.9] respectively. PCR showed 100% [111/111, 95% CI: 97-100] sensitivity for smear positive specimens. For smear negative specimens sensitivity and specificity of PCR against culture was observed to be 78.4% [69/88, 95% CI: 68.4-86.5] and 77.3% 204/264, 95% CI: 71.7-82.2] respectively and that against CRS was 68.1% [124/182, 95% CI: 60.874.8] and 97.1% [165/170, 95% CI: 93.3-99] respectively. Conclusion: CRS criteria were observed to be better than culture for assessing the diagnostic accuracy of PCR test. (C) 2013 Production and hosting by Elsevier B.V. on behalf of The Egyptian Society of Chest Diseases and Tuberculosis.
引用
收藏
页码:805 / 815
页数:11
相关论文
共 25 条
[1]   Approximate is better than "exact" for interval estimation of binomial proportions [J].
Agresti, A ;
Coull, BA .
AMERICAN STATISTICIAN, 1998, 52 (02) :119-126
[2]   Removal of PCR inhibitors by silica membranes:: Evaluating the amplicor Mycobacterium tuberculosis kit [J].
Böddinghaus, B ;
Wichelhaus, TA ;
Brade, V ;
Bittner, T .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (10) :3750-3752
[3]   Comparison of PCR, culture, and histopathology for diagnosis of tuberculous pericarditis [J].
Cegielski, JP ;
Devlin, BH ;
Morris, AJ ;
Kitinya, JN ;
Pulipaka, UP ;
Lema, LEK ;
Lwakatare, J ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) :3254-3257
[4]   Diagnosis of extrapulmonary tuberculosis by smear, culture, and PCR using universal sample processing technology [J].
Chakravorty, S ;
Sen, MK ;
Tyagi, JS .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (09) :4357-4362
[5]  
Chawla K, 2009, J INFECT DEV COUNTR, V3, P83
[6]   Clinical evaluation of the polymerase chain reaction for the rapid diagnosis of tuberculosis [J].
Cheng, VCC ;
Yam, WC ;
Hung, IFN ;
Woo, PCY ;
Lau, SKP ;
Tang, BSF ;
Yuen, KY .
JOURNAL OF CLINICAL PATHOLOGY, 2004, 57 (03) :281-285
[7]   In-house nucleic acid amplification tests for the detection of Mycobacterium tuberculosis in sputum specimens:: meta-analysis and meta-regression -: art. no. 55 [J].
Flores, LL ;
Pai, M ;
Colford, JM ;
Riley, LW .
BMC MICROBIOLOGY, 2005, 5 (1)
[8]   Diagnostic Accuracy of In-House PCR for Pulmonary Tuberculosis in Smear-Positive Patients: Meta-Analysis and Metaregression [J].
Greco, S. ;
Rulli, M. ;
Girardi, E. ;
Piersimoni, C. ;
Saltini, C. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (03) :569-576
[9]   Improved laboratory diagnosis of tuberculosis - The Indian experience [J].
Haldar, Sagarika ;
Bose, Mridula ;
Chakrabarti, Parul ;
Daginawala, Hatim F. ;
Harinath, B. C. ;
Kashyap, Rajpal S. ;
Kulkarni, Savita ;
Majumdar, Anindita ;
Prasad, H. Krishna ;
Rodrigues, Camilla ;
Srivastava, Ranjana ;
Taori, Girdhar M. ;
Varma-Basil, Mandira ;
Tyagi, Jaya S. .
TUBERCULOSIS, 2011, 91 (05) :414-426
[10]   AVOIDING FALSE POSITIVES WITH PCR [J].
KWOK, S ;
HIGUCHI, R .
NATURE, 1989, 339 (6221) :237-238