MODIFICATION OF A 3-DIMENSIONAL TREATMENT PLANNING SYSTEM FOR THE USE OF MULTI-LEAF COLLIMATORS IN CONFORMATION RADIOTHERAPY

被引:15
|
作者
BOESECKE, R [1 ]
BECKER, G [1 ]
ALANDT, K [1 ]
PASTYR, O [1 ]
DOLL, J [1 ]
SCHLEGEL, W [1 ]
LORENZ, WJ [1 ]
机构
[1] GERMAN CANC RES CTR,INST RADIOL & PATHOPYSIOL,IM NEUENHEIMER FELD 280,W-6900 HEIDELBERG 1,GERMANY
关键词
CONFORMATION RADIOTHERAPY; TREATMENT PLANNING; MULTI-LEAF COLLIMATOR; DOSE OPTIMIZATION;
D O I
10.1016/0167-8140(91)90051-H
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The multi-leaf collimator of the DKFZ is designed as a low cost add-on device for conventional linear accelerators for radiotherapy. The technical specification of the computer controlled collimator is described briefly. A major limitation in the use of the wide capabilities of multi-leaf collimators in the clinic is still an appropriate treatment planning system. This paper describes treatment planning and dose calculation techniques for multi-leaf collimators and shows examples where the capabilities of the collimator are used extensively.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 50 条
  • [21] USE OF PLANAR COMPENSATORS IN 3-DIMENSIONAL TREATMENT PLANNING
    BURMAN, C
    KUTCHER, GJ
    BAREST, G
    MOHAN, R
    MEDICAL PHYSICS, 1987, 14 (03) : 480 - 481
  • [22] Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery
    Cosgrove, VP
    Jahn, U
    Pfaender, M
    Bauer, S
    Budach, V
    Wurm, RE
    RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) : 325 - 336
  • [23] Effect of treatment planning system parameters on beam modulation complexity for treatment plans with single-layer multi-leaf collimator and dual-layer stacked multi-leaf collimator
    Quintero, Paulo
    Cheng, Yongqiang
    Benoit, David
    Moore, Craig
    Beavis, Andrew
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1122):
  • [24] COMPUTER-GRAPHICS TECHNIQUES IN 3-DIMENSIONAL RADIOTHERAPY TREATMENT PLANNING
    LONG, AP
    NICHOLAS, D
    BENTLEY, RE
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 808 - 808
  • [25] A COMPREHENSIVE 3-DIMENSIONAL RADIATION TREATMENT PLANNING SYSTEM
    MOHAN, R
    BAREST, G
    BREWSTER, LJ
    CHUI, CS
    KUTCHER, GJ
    LAUGHLIN, JS
    FUKS, Z
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (02): : 481 - 495
  • [26] 3-DIMENSIONAL TREATMENT PLANNING
    KUTCHER, GJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 108 - 108
  • [27] A NEW PRESCRIPTION AND VERIFICATION SYSTEM TO DRIVE MULTI-LEAF COLLIMATOR FOR CONVENTIONAL RADIOTHERAPY
    YU, CX
    DU, MN
    WONG, JW
    YAN, D
    MATTER, RC
    MARTINEZ, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 209 - 209
  • [28] USE OF A SIMULATED BEAMS EYE VIEW FOR POSITIONING BEAM BLOCKS IN 3-DIMENSIONAL RADIOTHERAPY TREATMENT PLANNING
    BATEMAN, TJ
    MEDICAL PHYSICS, 1986, 13 (04) : 590 - 590
  • [29] 3-DIMENSIONAL (3D) TREATMENT PLANNING IN RADIOTHERAPY OF BRAIN-TUMORS
    BIDMEAD, AM
    KAUSHAL, V
    HILL, LJ
    BRADA, M
    BRITISH JOURNAL OF CANCER, 1990, 61 (01) : 161 - 161
  • [30] COMPUTER-ASSISTED 3-DIMENSIONAL TREATMENT PLANNING SYSTEM
    REINSTEIN, LE
    MCSHAN, D
    WEBBER, BM
    GLICKSMAN, AS