0.1 MU-M X-RAY MASK REPLICATION

被引:13
|
作者
GENTILI, M
KUMAR, R
LUCIANI, L
GRELLA, L
PLUMB, D
LEONARD, Q
机构
[1] UNIV WISCONSIN, CTR X-RAY LITHOG, MADISON, WI 53706 USA
[2] CTR SCI INSTRUMENTS ORG, CHANDIGARH 160020, INDIA
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 1991年 / 9卷 / 06期
关键词
D O I
10.1116/1.585334
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a series of experiments, we investigate issues of absorber thickness increase (contrast amplification) and resolution capabilities of an x-ray mask copying process utilizing x-ray lithography. Two types of high resolution master masks were patterned using e-beam lithography and gold electroplating deposition and then replicated using x-ray lithography. The print quality and feature linewidths of each replica were then evaluated using a scanning electron microscope. The production of ULSI masks for x-ray lithography can be simplified if the necessary step of electron beam patterning can be performed in a thin resist layer, reducing the complexity of subsequent processing procedures and enhancing e-beam capabilities. When working with a thin resist, however, plated absorber thicknesses are small and the resulting mask contrast is limited. For x-ray lithography, Au absorber thicknesses on the order of 0.6-mu-m are required to ensure sufficient mask contrast when using synchrotron radiation (SR) sources (lambda = 0.1-1.2 nm). This implies than an aspect ratio of 3:1 is needed to print 0.2-mu-m features, and a ratio greater than 6:1 is necessary for sub-100 nm features. A promising approach to achieving greater absorber thickness in x-ray masks is based on a mask replication process utilizing x-ray lithography. The large depth of focus and wide process latitude offered by x-ray lithography (XRL) permit exposure into thicker resist layers, and consequently, greater absorber thicknesses can be produced via direct metallization of the printed image. This technique also has the advantage of reducing e-beam time requirements, since many x-ray mask replicas can be produced from a single e-beam master mask. Two types of master x-ray masks were used in our evaluation. The first was a 2-mu-m-thick SiNx membrane with sub-100-nm Au features, and the second was a 2-mu-m-thick Si membrane with Au features down to 250 nm. Using the SiNx master mask, sub-100-nm resist features were successfully printed in 600 nm of resist on base plated wafers, using x-ray lithography. Subsequent electroplating of these samples yielded sub-100 nm features with Au absorber thicknesses of 450 nm. These results demonstrate successful mask contrast amplification (from 6 dB for the master to 15 dB for the copy), and show that high resolution, high contrast masks can be fabricated using this replication process.
引用
收藏
页码:3319 / 3323
页数:5
相关论文
共 50 条
  • [21] MIX AND MATCH LITHOGRAPHY FOR 0.1 MU-M MOSFET FABRICATION
    MIEVILLE, JP
    BARRIER, J
    SHI, Z
    DUTOIT, M
    OPPLIGER, Y
    MORET, JM
    PERRET, A
    MICROELECTRONIC ENGINEERING, 1991, 13 (1-4) : 189 - 192
  • [22] A ROOM-TEMPERATURE 0.1 MU-M CMOS ON SOI
    SHAHIDI, GG
    ANDERSON, CA
    CHAPPELL, BA
    CHAPPELL, TI
    COMFORT, JH
    DAVARI, B
    DENNARD, RH
    FRANCH, RL
    MCFARLAND, PA
    NEELY, JS
    NING, TH
    POLCARI, MR
    WARNOCK, JD
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (12) : 2405 - 2412
  • [23] EFFECTS OF INDUCED SPATIAL INCOHERENCE ON LASER-LIGHT ABSORPTION AND X-RAY CONVERSION AT 0.53 MU-M
    BOSCH, RA
    GABL, EF
    SIMPSON, JD
    ARMENTROUT, CJ
    FAILOR, BH
    KANIA, DR
    BELL, PM
    PHYSICAL REVIEW A, 1991, 43 (02): : 953 - 960
  • [24] X-RAY SPECTROSCOPY OF PLASMAS FROM GLASS MICROSPHERES IRRADIATED WITH 10 MU-M LASER-LIGHT
    MITCHELL, KB
    VANHULSTEYN, D
    LEE, P
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) : 547 - 547
  • [25] 3-DIMENSIONAL DISTRIBUTION OF MINERAL IN BONE AT A RESOLUTION OF 15 MU-M DETERMINED BY X-RAY MICROTOMOGRAPHY
    ELLIOTT, JC
    DOVER, SD
    METABOLIC BONE DISEASE & RELATED RESEARCH, 1984, 5 (05): : 219 - 221
  • [26] X-RAY BACKLIGHTING MEASUREMENTS OF PLANE AL TARGET VELOCITY IN 0.35 MU-M LASER INTERACTION EXPERIMENTS
    THIELL, G
    MEYER, B
    AUSSAGE, P
    FORTIN, X
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1983, 296 (04): : 209 - 212
  • [27] X-ray emission from M32: X-ray binaries or a mu AGN?
    Eskridge, PB
    White, RE
    Davis, DS
    ASTROPHYSICAL JOURNAL, 1996, 463 (02): : L59 - &
  • [28] SYNCHROTRON X-RAY-DIFFRACTION FROM A 800 MU-M ZEOLITE MICROCRYSTAL
    EISENBERGER, P
    NEWSAM, JM
    LEONOWICZ, ME
    VAUGHAN, DEW
    NATURE, 1984, 309 (5963) : 45 - 47
  • [29] NORMAL-INCIDENCE X-RAY MICROSCOPE FOR CARBON K-ALPHA RADIATION WITH 0.5 MU-M RESOLUTION
    MURAKAMI, K
    OSHINO, T
    NAKAMURA, H
    OHTANI, M
    NAGATA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1992, 31 (10B): : L1500 - L1502
  • [30] SELECTIVE TUNGSTEN FILLING OF SUB-0.25 MU-M TRENCHES FOR THE FABRICATION OF SCALED CONTACTS AND X-RAY MASKS
    MALUF, NI
    CHOU, SY
    PEASE, RFW
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1990, 8 (03): : 568 - 569