THE EFFECT OF ELECTRICAL PERTURBATION ON OSSEOINTEGRATION OF TITANIUM DENTAL IMPLANTS - A PRELIMINARY-STUDY

被引:12
|
作者
SHAFER, DM [1 ]
ROGERSON, K [1 ]
NORTON, L [1 ]
BENNETT, J [1 ]
机构
[1] UNIV CONNECTICUT,CTR HLTH,SCH DENT MED,DEPT ORTHODONT,FARMINGTON,CT
关键词
D O I
10.1016/0278-2391(95)90125-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Successful osseointegration of titanium dental implants is decreased in areas of poor bone volume and density, Low amperage direct current (LADC) has been shown to perturb bone cells, which in turn promotes bone growth, The purpose of this experiment was to evaluate the effect of LADC on the osseointegration of endosseous titanium dental implants. Materials and Methods: Two implant sites were prepared in the body of the mandible of five rabbits by an extraoral approach. An LADC-stimulated 3.75 x 7 mm-titanium implant was placed in one site and an identical control implant was inserted on the contralateral side. A sterilized silicone-encased power pack producing 7.5 +/- 0.2 uA and 1.35 +/- 0.01 V was placed in a submandibular pouch, The active cathode lead was attached to the LADC implant and the anode was placed in the mandible 5 mm distal to the implant, Nonactive leads were similarly connected to the control implant. Twenty-eight days after placement, the implants were removed using a torque wrench, and the bone surrounding the implants was examined both microscopically and radiographically. Results: The average force to initial rotation was 1,320 +/- 880 g/cm for the LADC-stimulated implants and 1,290 +/- 238 g/cm for the control implants. This was not significantly different by t test (P = .94), Light microscopic evaluation demonstrated a mixture of compact and woven bone and fibrous tissue adjacent to both groups of implants. Histomorphometric analysis demonstrated an average percent of bone in relation to the total tissue adjacent to the control implants of 33.5 +/- 15.4 and 40.2 +/- 4.8 for the LADC-stimulated implants (not significantly different, t test, P = .39). Conclusion: It was concluded that LADC as used in this study does not positively affect the healing of bone. Its ability to enhance bone growth around titanium dental implants needs further investigation.
引用
收藏
页码:1063 / 1068
页数:6
相关论文
共 50 条
  • [31] Ultrashort Pulsed Laser Surface Patterning of Titanium to Improve Osseointegration of Dental Implants
    Zwahr, Christoph
    Welle, Alexander
    Weingaertner, Tobias
    Heinemann, Christiane
    Kruppke, Benjamin
    Gulow, Nikolai
    Holthaus, Marzellus Grosse
    Lasagni, Andres Fabian
    ADVANCED ENGINEERING MATERIALS, 2019, 21 (12)
  • [32] Surface characteristics of titanium dental implants with improved microdesigns: An in vivo study of their osseointegration performance in goat mandible
    Mistry, Surajit
    Burman, Subhasish
    Roy, Subhasis
    Maitra, Nilendu Hoti
    Roy, Rajiv
    Chanda, Abhijit
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2021, 35 (07) : 799 - 813
  • [33] Osseointegration of Low Elastic Modulus Titanium Alloy Dental Implants with Electrochemical Modification: An Experimental Study in Dogs
    Feng, Lifang
    Liang, Xinjie
    Wu, Lin
    Yang, Junying
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2015, 5 (12) : 974 - 980
  • [34] The Biocompatibility and the Effect of Titanium and PEKK on the Osseointegration of Customized Facial Implants
    Hong, Sung-Ok
    Pyo, Ju-Yeon
    On, Sung-Woon
    Seo, Ja-Yeong
    Choi, Jin-Young
    MATERIALS, 2024, 17 (17)
  • [35] Effect of antiangiogenic targeted chemotherapy on the osseointegration of titanium implants in rabbits
    Al-Jandan, B.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2019, 57 (02): : 157 - 163
  • [36] The effect of titanium aluminium nitride on the osseointegration of metallic implants.
    Freeman, CO
    Brook, IM
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1064 - 1064
  • [37] The Effect of Systemic Nicotine on Osseointegration of Titanium Implants in the Rat Femur
    Berley, Joel
    Yamano, Seiichi
    Sukotjo, Cortino
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (03) : 185 - 194
  • [38] The effect of slow speed drilling on the stability of dental implants during osseointegration: a clinical study
    Demir, B.
    Bedeloglu, E.
    Koyuncuoglu, C. Z.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (02) : 91 - 94
  • [39] The effect of systemically administrated zoledronic acid on the osseointegration of dental implants
    Ayan, M.
    Dolanmaz, D.
    Mihmanli, A.
    Ayan, A.
    Kurkcu, M.
    ORAL DISEASES, 2012, 18 (08) : 802 - 808
  • [40] Effect of Zoledronic Acid on Osseointegration of Titanium Implants: An Experimental Study in an Ovariectomized Rabbit Model
    Yildiz, Alper
    Esen, Emin
    Kurkcu, Mehmet
    Damlar, Ibrahim
    Daglioglu, Kenan
    Akova, Tolga
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (03) : 515 - 523