QUANTITATION OF GLUCOSE-CONCENTRATION USING A GLUCOSE OXIDASE CATALASE ELECTRODE BY POTENTIOMETRIC MEASUREMENT

被引:29
|
作者
LIU, CC
WINGARD, LB
WOLFSON, SK
YAO, SJ
DRASH, AL
SCHILLER, JG
机构
[1] UNIV PITTSBURGH,SCH MED,DEPT PHARMACOL,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,SCH MED,DEPT NEUROL SURG,PITTSBURGH,PA 15260
[3] UNIV PITTSBURGH,SCH MED,DEPT PEDIAT,PITTSBURGH,PA 15260
来源
BIOELECTROCHEMISTRY AND BIOENERGETICS | 1979年 / 6卷 / 01期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0302-4598(79)85003-5
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glucose oxidase and catalase were immobilized in polyacrylamide gel around a platinum screen and used to measure the concentration of glucose in 0.1 M phosphate buffer, pH 7.3, at 37°C. This enzyme electrode produced a direct potentiometric signal with reference to a standard Ag|AgCl electrode. The potential difference was linearly related to the logarithm of the concentration of glucose over the range of 3-40 cg/dm3 (mg/dl). The electrode was stable for at least 32 hours at 37°C. Hydrogen peroxide, generated by the oxidation of glucose and depleted by decomposition and diffusion, was the apparent source of the potentiometric signal. Direct potentiometric measurement has the advantages of simple readout, continuous detection, and small electrode size, and does not require external polarising potential. This approach should be suitable for the continuous in vivo monitoring of blood glucose levels if the upper limit of specificity for glucose (presently 40 mg/dl) can be extended. © 1979.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] Potentiometric glucose determination in human serum samples with glucose oxidase biosensor based on iodide electrode
    E. Karakuş
    Ş. Pekyardımcı
    E. Kiliç
    Applied Biochemistry and Microbiology, 2013, 49 : 194 - 198
  • [22] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [23] A SYSTEM FOR THE ONLINE DETERMINATION OF GLUCOSE-CONCENTRATION
    LEUNG, KK
    PETERSEN, JN
    LEE, JM
    BIOPROCESS ENGINEERING, 1991, 7 (1-2): : 19 - 23
  • [24] UTEROPLACENTAL GLUCOSE-UPTAKE VS MATERNAL GLUCOSE-CONCENTRATION
    HAY, WW
    BATTAGLIA, FC
    MESCHIA, G
    FEDERATION PROCEEDINGS, 1983, 42 (03) : 467 - 467
  • [25] VARIATIONS IN GLUCOSE-CONCENTRATION AROUND THE MOUTH
    WEATHERELL, JA
    STRONG, M
    ROBINSON, C
    RALPH, JP
    CARIES RESEARCH, 1988, 22 (02) : 116 - 116
  • [26] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [27] COMBINATION OF MICRODIALYSIS AND GLUCOSE SENSOR FOR CONTINUOUS ON LINE MEASUREMENT OF THE SUBCUTANEOUS GLUCOSE-CONCENTRATION - THEORY AND PRACTICAL APPLICATION
    MEYERHOFF, C
    MENNEL, FJ
    BISCHOF, F
    STERNBERG, F
    PFEIFFER, EF
    HORMONE AND METABOLIC RESEARCH, 1994, 26 (11) : 538 - 543
  • [28] Electrochemical determination of glucose using polyaniline electrode modified by glucose oxidase
    Gvozdenovic, M. M.
    Jugovic, B. Z.
    Bezbradica, D. I.
    Antov, M. G.
    Knezevic-Jugovic, Z. D.
    Grgur, B. N.
    FOOD CHEMISTRY, 2011, 124 (01) : 396 - 400
  • [29] HIGHLY SENSITIVE GLUCOSE ELECTRODE USING GLUCOSE OXIDASE COLLAGEN FILM
    THEVENOT, DR
    COULET, PR
    STERNBERG, R
    GAUTHERON, DC
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1978, 5 (03): : 548 - 553
  • [30] FETAL GLUCOSE-UPTAKE AND UTILIZATION AS FUNCTIONS OF MATERNAL GLUCOSE-CONCENTRATION
    HAY, WW
    SPARKS, JW
    WILKENING, RB
    BATTAGLIA, FC
    MESCHIA, G
    AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03): : E237 - E242