ELECTROSPRAY-IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY IN PROTEIN CHEMISTRY

被引:93
|
作者
MIRGORODSKAYA, OA
SHEVCHENKO, AA
CHERNUSHEVICH, IV
DODONOV, AF
MIROSHNIKOV, AI
机构
[1] RUSSIAN ACAD SCI,INST ENERGY PROBLEMS CHEM PHYS,CHERNOGOLOVKA 142432,RUSSIA
[2] MM SHEMYAKIN INST BIOORGAN CHEM,MOSCOW 117871,RUSSIA
关键词
D O I
10.1021/ac00073a018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel electrospray ionization time-of-flight mass spectrometer with an ion mirror has been developed. The ''orthogonal acceleration'' of ions combined with ion storage modulation enables large sensitivity to be obtained with moderate (R > 2000) mass resolution. Application of the transient recording system allows simultaneous registration of ions of all masses, with sensitivity equal to that in the single ion monitoring regime. The potential of this technique is demonstrated by the primary structure determination of cationic peptides from porcine neutrophils and by the study of the pathways of recombinant proinsulin proteolytic processing catalyzed by various trypsin forms.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [21] COOPERATIVE ELEMENTS IN PROTEIN-FOLDING MONITORED BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    HOOKE, SD
    EYLES, SJ
    MIRANKER, A
    RADFORD, SE
    ROBINSON, CV
    DOBSON, CM
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (28) : 7548 - 7549
  • [22] SURFACTANT EFFECTS ON PROTEIN-STRUCTURE EXAMINED BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LOO, RRO
    DALES, N
    ANDREWS, PC
    PROTEIN SCIENCE, 1994, 3 (11) : 1975 - 1983
  • [23] EVALUATION OF HISTONE SEQUENCE AND MODIFICATIONS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY
    EDMONDS, CG
    LOO, JA
    SMITH, RD
    FUCIARELLI, AF
    THRALL, BD
    MORRIS, JE
    SPRINGER, DL
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 40 (2-3): : 159 - 159
  • [24] Capillary isoelectric focusing electrospray ionization time-of-flight mass spectrometry for protein analysis
    Wei, J
    Lee, CS
    Lazar, IM
    Lee, ML
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (03) : 193 - 197
  • [25] ANALYSIS OF SERUM-PROTEIN PRECIPITATED WITH ANTISERUM BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT AND ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY AS A CLINICAL LABORATORY TEST
    NAKANISHI, T
    SHIMIZU, A
    OKAMOTO, N
    INGENDOH, A
    KANAI, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (09) : 854 - 859
  • [26] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY - A QUANTITATIVE SNAPSHOT ON AN INSTRUMENTAL BREAKTHROUGH
    BRAUN, T
    ZSINDELY, S
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (09) : 307 - 309
  • [27] Electrospray-ionization mass spectrometry for protein conformational studies
    Grandori, R
    CURRENT ORGANIC CHEMISTRY, 2003, 7 (15) : 1589 - 1603
  • [28] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY AS A TOOL FOR MONITORING LIPID A HYDROLYSIS
    COLE, RB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 115 - ANYL
  • [29] CHARACTERIZATION OF BACTERIAL PHOSPHOLIPIDS BY ELECTROSPRAY-IONIZATION TANDEM MASS-SPECTROMETRY
    SMITH, PBW
    SNYDER, AP
    HARDEN, CS
    ANALYTICAL CHEMISTRY, 1995, 67 (11) : 1824 - 1830
  • [30] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF RECOMBINANTLY ENGINEERED ANTIBODY FRAGMENTS
    BOURELL, JH
    CLAUSER, KP
    KELLEY, R
    CARTER, P
    STULT, JT
    ANALYTICAL CHEMISTRY, 1994, 66 (13) : 2088 - 2095