DEVELOPMENT OF MEDIATED AMPEROMETRIC BIOSENSORS FOR HYPOXANTHINE, GLUCOSE AND LACTATE - A NEW FORMAT

被引:22
|
作者
NGUYEN, AL [1 ]
LUONG, JHT [1 ]
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL H4P 2R2,PQ,CANADA
来源
BIOSENSORS & BIOELECTRONICS | 1993年 / 8卷 / 9-10期
关键词
MEDIATED AMPEROMETRIC BIOSENSORS; GLUCOSE; LACTATE; HYPOXANTHINE; FISH FRESHNESS TETRATHIAFULVALENE (TTF); TETRACYANOQUINODIMETHANE (TCNQ); ELECTROCHEMICAL GROWTH;
D O I
10.1016/0956-5663(93)80027-M
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrochemical growth was used to form the organic conducting salt of tetrathiafulvalene (TTF) and tetracyanoquinodimethane (TCNQ) on platinum wires inserted in a glass capillary. Glucose oxidase, lactate oxidase and xanthine oxidase were deposited and crosslinked on the salt structure to produce mediated biosensors responsive to the corresponding analytes. Reliability, stability, interference, and the effect of oxygen on the electrode's response were studied. Among three common electroactive interfering substances tested, ascorbic acid was very active at the TTF-TCNQ structure and the highest response was exhibited by the enzyme-free electrode. Acetaminophen and uric acid displayed similar behaviour at a lower magnitude. The presence of oxygen significantly decreased the current responses of all electrodes. The xanthine oxidase-bearing mediated electrodes were able to assay the hypoxanthine content of either the fish extract, fish homogenate or slurry of manually ground tissue, yielding results in good agreement with conventional enzymatic assays. The electrodes were stable more than 120 days and could be reused more than 30 times without losing their original activities.
引用
收藏
页码:421 / 431
页数:11
相关论文
共 50 条
  • [31] Micromachined amperometric cells for continuous monitoring of glucose and lactate
    Dudde, R.
    Piechotta, G.
    Hintsche, R.
    1ST TRANSDISCIPLINARY CONFERENCE ON DISTRIBUTED DIAGNOSIS AND HOME HEALTHCARE, CONFERENCE PROCEEDINGS, 2006, : 1 - +
  • [32] A CMOS Potentiostatic Glucose Monitoring System for VACNF Amperometric Biosensors
    Al Mamun, Khandaker Abdullah
    McFarlane, Nicole
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 477 - 480
  • [33] INK-JET PRINTING FOR THE FABRICATION OF AMPEROMETRIC GLUCOSE BIOSENSORS
    NEWMAN, JD
    TURNER, APF
    MARRAZZA, G
    ANALYTICA CHIMICA ACTA, 1992, 262 (01) : 13 - 17
  • [34] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    TALANTA, 1991, 38 (01) : 107 - 110
  • [35] EXTRACORPOREAL DETERMINATION OF GLUCOSE, LACTATE AND POTASSIUM WITH ELECTROCHEMICAL BIOSENSORS
    MASCINI, M
    PALLESCHI, G
    MOSCONE, D
    BERNARDI, L
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) : 1377 - 1383
  • [36] Reagentless Amperometric Glucose Biosensors: Ferrocene-Tethering and Copolymerization
    Altun, Ayhan
    Apetrei, Roxana-Mihaela
    Camurlu, Pinar
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (10)
  • [37] RECENT ADVANCES IN AMPEROMETRIC GLUCOSE BIOSENSORS FOR IN-VIVO MONITORING
    JAFFARI, SA
    TURNER, APF
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (01) : 1 - 15
  • [38] AMPEROMETRIC BIOSENSORS FOR ONLINE MONITORING OF EXTRACELLULAR GLUCOSE AND GLUTAMATE IN THE BRAIN
    ZILKHA, E
    KOSHY, A
    OBRENOVITCH, TP
    BENNETTO, HP
    SYMON, L
    ANALYTICAL LETTERS, 1994, 27 (03) : 453 - 473
  • [39] Tobacco Peroxidase as a New Reagent for Amperometric Biosensors
    I. G. Gazaryan
    L. Gorton
    T. Ruzgas
    E. Csoregi
    W. Schuhmann
    L. M. Lagrimini
    D. M. Khushpul’yan
    V. I. Tishkov
    Journal of Analytical Chemistry, 2005, 60 : 558 - 566
  • [40] Tobacco peroxidase as a new reagent for amperometric biosensors
    Gazaryan, IG
    Gorton, L
    Ruzgas, T
    Csoregi, E
    Schuhmann, W
    Lagrimini, LM
    Khushpul'yan, DM
    Tishkov, VI
    JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 60 (06) : 558 - 566