DEVELOPMENT OF MEDIATED AMPEROMETRIC BIOSENSORS FOR HYPOXANTHINE, GLUCOSE AND LACTATE - A NEW FORMAT

被引:22
|
作者
NGUYEN, AL [1 ]
LUONG, JHT [1 ]
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL H4P 2R2,PQ,CANADA
来源
BIOSENSORS & BIOELECTRONICS | 1993年 / 8卷 / 9-10期
关键词
MEDIATED AMPEROMETRIC BIOSENSORS; GLUCOSE; LACTATE; HYPOXANTHINE; FISH FRESHNESS TETRATHIAFULVALENE (TTF); TETRACYANOQUINODIMETHANE (TCNQ); ELECTROCHEMICAL GROWTH;
D O I
10.1016/0956-5663(93)80027-M
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrochemical growth was used to form the organic conducting salt of tetrathiafulvalene (TTF) and tetracyanoquinodimethane (TCNQ) on platinum wires inserted in a glass capillary. Glucose oxidase, lactate oxidase and xanthine oxidase were deposited and crosslinked on the salt structure to produce mediated biosensors responsive to the corresponding analytes. Reliability, stability, interference, and the effect of oxygen on the electrode's response were studied. Among three common electroactive interfering substances tested, ascorbic acid was very active at the TTF-TCNQ structure and the highest response was exhibited by the enzyme-free electrode. Acetaminophen and uric acid displayed similar behaviour at a lower magnitude. The presence of oxygen significantly decreased the current responses of all electrodes. The xanthine oxidase-bearing mediated electrodes were able to assay the hypoxanthine content of either the fish extract, fish homogenate or slurry of manually ground tissue, yielding results in good agreement with conventional enzymatic assays. The electrodes were stable more than 120 days and could be reused more than 30 times without losing their original activities.
引用
收藏
页码:421 / 431
页数:11
相关论文
共 50 条
  • [21] Composite transducers for amperometric biosensors. The glucose sensor
    Svorc, J
    Miertus, S
    Katrlik, J
    Stredansky, M
    ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2086 - 2090
  • [22] Recent advances in amperometric glucose biosensors for in vivo monitoring
    Jaffari, S.A.
    Turner, A.P.F.
    Physioligical Measurement, 1995, 16 (01):
  • [23] Bulk-modified amperometric biosensors for hypoxanthine based on sol-gel technique
    Niu, JJ
    Lee, JY
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (03): : 190 - 198
  • [24] Electrochemically platinized carbon paste enzyme electrodes: A new design of amperometric glucose biosensors
    Liang Ming
    Xia Xi
    Jie Liu
    Biotechnology Letters, 2006, 28 : 1341 - 1345
  • [25] Amperometric lactate biosensors and their application in (sports) medicine, for life quality and wellbeing
    Nadia Nikolaus
    Beate Strehlitz
    Microchimica Acta, 2008, 160 : 15 - 55
  • [26] Electrochemically platinized carbon paste enzyme electrodes: A new design of amperometric glucose biosensors
    Ming, Liang
    Xi, Xia
    Liu, Jie
    BIOTECHNOLOGY LETTERS, 2006, 28 (17) : 1341 - 1345
  • [27] Amperometric biosensors for detection of choline and lactate by Choline Oxidase and Lactate Oxidase immobilisation in microporous membranes
    Makela, Timo
    Albers, Martin
    VTT Tiedotteita - Valtion Teknillinen Tutkimuskeskus, (1775):
  • [28] Amperometric lactate biosensors and their application in (sports) medicine, for life quality and wellbeing
    Nikolaus, Nadia
    Strehlitz, Beate
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 15 - 55
  • [29] The Development of New Nonenzymatic Glucose Biosensors Using Nanomaterials
    Su, Jie
    Shu, Honghui
    Chang, Gang
    Zhang, Yuting
    Zhou, Yingying
    Xia, Tiantian
    Jia, Hongmei
    He, Yunbin
    CURRENT NANOSCIENCE, 2015, 11 (06) : 736 - 747
  • [30] Development of Anodic Titania Nanotubes for Application in High Sensitivity Amperometric Glucose and Uric Acid Biosensors
    Lee, Hsiang-Ching
    Zhang, Li-Fan
    Lin, Jyh-Ling
    Chin, Yuan-Lung
    Sun, Tai-Ping
    SENSORS, 2013, 13 (10): : 14161 - 14174