In 2-D time-of-flight MR angiography (2-D TOF MRA) of the liver, artifacts caused by respiratory motion are unavoidable. Therefore, a 3-D black blood MRA of the liver was attempted in 7 healthy volunteers, using a 3-D gradient echo sequence which allows imaging during breath holding. 2-D TOF MRA was performed as well. In all subjects, 3-D MRA allowed visualization of the trunk, 1st-, and 2nd-order branches of the portal vein without interruption. Right 3rd-order branches were visualized without interruption in 6 of 7 subjects (85%). However, with 2-D MRA, the transverse portion of the left main portal vein could not be visualized in any subject, and the periphery of the portal vein was less clear than with 3-D MRA.