FLOW-INJECTION ANALYSIS OF AMMONIA AND SULFUR-DIOXIDE WITH PIEZOELECTRIC DETECTION

被引:8
|
作者
KRAWCZYK, TKV
TROJANOWICZ, M
机构
[1] Department of Chemistry, University of Warsaw, Pasteura 1
关键词
FLOW INJECTION ANALYSIS; PIEZOELECTRIC DETECTION; SULFUR DIOXIDE; AMMONIA;
D O I
10.2116/analsci.8.329
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As crystal-coating materials used for ammonia sensors, hydrochlorides of pyridoxine, glutamic acid, histidine, methionine, alanine and cysteine were examined. By using the first three of them a satisfactory detection of ammonia in the wide range from 1 ppb to 10(3) ppm could be obtained. Under optimized conditions the lifetime of a histidine hydrochloride-based sensor can be extended to 1 month, whereas for a pyridoxine hydrochloride-based detector, due to the possibility of regeneration, even up to 4 months is possible. Among several compounds examined as coating substances for sulfur dioxide detection, tripropylamine and tridodecylamine can be utilized only for the determination of a large concentration of SO2, above 0.1% v/v. N,N,N',N'-tetrakis(2-hydroxyethyl)ethylenediamine (EDTE) and N,N,N',N'-tetrakis(2-hydroxypropyl)ethylenediamine (EDTP) can be employed for a much lower range Of SO2 concentrations, namely 1 to 1000 and 0.01 to 1000 ppm for EDTE and EDTP, respectively. A lifetime study Of SO2 detectors has shown that although an EDTP-based SO2 sensor can be used for 2 months, its detectability gradually deteriorates. Upon using an EDTP-based sensor some disadvantages of serial syringe dilution for the preparation of gas standard mixtures were noted. For a comparison, an alternative procedure employing gas-permeable tubing was proposed.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 50 条
  • [21] DETECTION OF SOURCE LEVELS OF SULFUR-DIOXIDE USING A PIEZOELECTRIC DETECTOR AND PERMEATION MEMBRANE
    CHENEY, J
    NORWOOD, T
    HOMOLYA, J
    ANALYTICAL LETTERS, 1976, 9 (06) : 557 - 578
  • [22] REPETITIVE DETERMINATIONS OF SULFUR-DIOXIDE GAS IN AIR SAMPLES BY FLOW-INJECTION AND CHEMICAL-REACTION AT A GAS-LIQUID INTERFACE
    RAMASAMY, SM
    MOTTOLA, HA
    ANALYTICAL CHEMISTRY, 1982, 54 (02) : 283 - 286
  • [23] DETERMINATION OF TOTAL AND FREE SULFUR-DIOXIDE IN WINE BY FLOW-INJECTION ANALYSIS AND GAS-DIFFUSION USING PARA-AMINOAZOBENZENE AS THE COLORIMETRIC-REAGENT
    BARTROLI, J
    ESCALADA, M
    JORQUERA, CJ
    ALONSO, J
    ANALYTICAL CHEMISTRY, 1991, 63 (21) : 2532 - 2535
  • [24] DETECTION OF SULFUR-DIOXIDE IN BRONCHODILATOR AEROSOLS
    WITEK, TJ
    SCHACHTER, EN
    CHEST, 1984, 86 (04) : 592 - 594
  • [25] RADIO DETECTION OF INTERSTELLAR SULFUR-DIOXIDE
    SNYDER, LE
    HOLLIS, JM
    ULICH, BL
    LOVAS, FJ
    JOHNSON, DR
    BUHL, D
    ASTROPHYSICAL JOURNAL, 1975, 198 (02): : L81 - L84
  • [26] THE USE OF A PIEZOELECTRIC CRYSTAL TO DETERMINE SULFUR-DIOXIDE IN GASES
    PRIBIL, R
    BILKOVA, E
    TALANTA, 1992, 39 (04) : 361 - 366
  • [27] EVALUATION OF SUBSTRATES FOR USE ON A PIEZOELECTRIC DETECTOR FOR SULFUR-DIOXIDE
    FRECHETTE, MW
    FASCHING, JL
    ROSIE, DM
    ANALYTICAL CHEMISTRY, 1973, 45 (09) : 1765 - 1766
  • [28] Sequential determination of carbon dioxide and free sulfur dioxide in wine by flow-injection pervaporation with in series potentiometric-photometric detection
    Mataix, E
    de Castro, MDL
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (04): : 377 - 380
  • [29] Sequential determination of carbon dioxide and free sulfur dioxide in wine by flow-injection pervaporation with in series potentiometric-photometric detection
    E. Mataix
    M. D. Luque de Castro
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 377 - 380
  • [30] FLOW-INJECTION ANALYSIS OF FAMOTIDINE WITH SPECTROPHOTOMETRIC DETECTION
    KAMATH, BV
    SHIVRAM, K
    VANGANI, S
    ANALYTICAL LETTERS, 1993, 26 (10) : 2183 - 2191