Normal values for cerebrospinal fluid flow dynamics in the aqueduct of Sylvius through optimized analysis of phase-contrast MR images

被引:10
作者
Florez, N. [1 ]
Marti-Bonmati, L. [2 ]
Forner, J. [2 ]
Arana, E. [2 ]
Moratal, D. [1 ]
机构
[1] Univ Politecn Valencia, Grp Ingn Biosenales & Imagen Radiol, Valencia, Spain
[2] Hosp Quiron, Serv Radiol, Valencia, Spain
来源
RADIOLOGIA | 2009年 / 51卷 / 01期
关键词
Magnetic resonance; Cerebrospinal fluid; Quantitative analysis; Flow imaging;
D O I
10.1016/S0033-8338(09)70404-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: to establish normal values for the different parameters that characterize the cerebrospinal fluid (CSF) flow dynamics in the aqueduct of Sylvius (velocity, flow, volume per cycle, and CSF production) obtained from phase-contrast MR images using a reliable and reproducible post-processing method. The optimized semiautomatic method eliminates interobserver variability and corrects errors due to low amplitude movements, aliasing, and the partial volume effect. Material and methods: we studied 42 healthy subjects without neurological or cerebrovascular disease or disturbances in CSF dynamics. Images were acquired on a 1.5 T MR scanner using a phase-contrast sequence. All images were acquired during the same time frame (14: 00 to 18: 00) to avoid circadian influences. Results: we obtained normal values for each of the parameters that characterize CSF dynamics in the aqueduct (maximum diastolic and systolic velocity, mean velocity, maximum diastolic and systolic fl ow, mean fl ow, production rate, and stroke volume). Although trends were noted, neither sex nor age (< 25, 26-50, > 51 years old) had a statistically significant effect on any parameter (p = 0.05). Discussion: although measurements of CSF fl ow dynamics parameter are sensitive to various factors (temporal and spatial resolutions of the MR sequence, circadian rhythms, age, sex, and MR equipment manufacturer), an optimized post-processing method enables reliable and reproducible values and ranges for normal subjects to be established. (C) 2007 SERAM. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 22 条
[1]   PHASE-CONTRAST CINE MR-IMAGING OF NORMAL AQUEDUCTAL CSF FLOW - EFFECT OF AGING AND RELATION TO CSF VOID ON MODULUS MR [J].
BARKHOF, E ;
KOUWENHOVEN, M ;
SCHELTENS, P ;
SPRENGER, M ;
ALGRA, P ;
VALK, J .
ACTA RADIOLOGICA, 1994, 35 (02) :123-130
[2]   The pathophysiology of the aqueduct stroke volume in normal pressure hydrocephalus: can co-morbidity with other forms of dementia be excluded? [J].
Bateman, GA ;
Levi, CR ;
Schofield, P ;
Wang, Y ;
Lovett, EC .
NEURORADIOLOGY, 2005, 47 (10) :741-748
[3]   Normal-pressure hydrocephalus: Evaluation with cerebrospinal fluid flow measurements at MR imaging [J].
Bradley, WG ;
Scalzo, D ;
Queralt, J ;
Nitz, WN ;
Atkinson, DJ ;
Wong, P .
RADIOLOGY, 1996, 198 (02) :523-529
[4]  
Bradley William G. Jr., 1992, Magnetic Resonance Quarterly, V8, P169
[5]   Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius [J].
Florez, Yudy Natalia ;
Moratal, David ;
Forner, Juana ;
Marti-Bonmati, Luis ;
Arana, Estanislao ;
Guajardo-Hernandez, Ulises ;
Millet-Roig, Jose .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (02) :78-87
[6]  
Forner J, 2007, NEUROLOGIA, V22, P213
[7]  
Forner J, 2007, REV ARGENT RADIOL, V71, P199
[8]  
Giiang L, 2000, CHIN J RADIOL, V25, P191
[9]   Effect of acquisition parameters on the accuracy of velocity encoded cine magnetic resonance imaging blood flow measurements [J].
Greil, G ;
Geva, T ;
Maier, SE ;
Powell, AJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (01) :47-54
[10]  
Hakim S, 1965, J Neurol Sci, V2, P307, DOI 10.1016/0022-510X(65)90016-X