COMPARATIVE MICRONUCLEUS QUANTITATION IN PRECOLUMN AND POSTCOLUMN FRACTIONATED MOUSE BONE-MARROW BY MANUAL AND FLOW METHODS

被引:7
|
作者
KIRSHNA, G
BROTT, D
URDA, G
MCKEEL, M
ZANDEE, J
THEISS, J
机构
[1] Department of Pathology and Experimental Toxicology, Parke-Davis Pharmaceutical Research Division, Warner-Lambert Company, Ann Arbor
来源
MUTATION RESEARCH | 1993年 / 302卷 / 02期
关键词
MICRONUCLEUS QUANTITATION; COMPARATIVE; CELLULOSE-COLUMN FRACTIONATION METHODOLOGY; SMEAR METHODOLOGY; STANDARD; CYCLOPHOSPHAMIDE;
D O I
10.1016/0165-7992(93)90013-L
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
In the present study, cellulose-column fractionation methodology which has been used to eliminate nucleated cells in bone marrow was verified for its usefulness in micronucleus analysis and compared to standard smear methodology using cyclophosphamide as the test compound. Also, the possibility of using column-fractionated cells in the evaluation of micronucleus frequency by flow cytometry has been explored and comparative results are reported. The results indicated that column fractionation was effective in removing nucleated cells from mouse bone marrow and provided clean preparations of polychromatic and normochromatic erythrocytes (PCEs and NCEs). An initial comparison of manual scoring of cyclophosphamide-induced (10, 20 or 40 mg/kg) micronucleus frequency between standard whole bone-marrow smear and column-fractionated cytospun smears from the same animals showed comparable results. In a definitive study, manual scoring of micronuclei in whole bone marrow was compared with the column-fractionated cell preparations quantified manually and using flow cytometry. Statistically significant positive dose-related trends were detected with all 3 methods, with each treatment group having significantly elevated micronucleated PCEs (MNPCEs) compared to the control group. The 3 methods provided comparable MNPCE values for the lower dose groups but diverged somewhat for the high dose group. The flow method yielded similar individual animal variability in the data when compared to the other two methods. These results support the use of column fractionation in the enumeration of MNPCEs and indicate that coupling this technique with flow cytometry may provide a rapid and sensitive method for the conduct of mouse bone-marrow micronucleus studies.
引用
收藏
页码:119 / 127
页数:9
相关论文
共 4 条
  • [1] COMPARATIVE MOUSE MICRONUCLEUS EVALUATION IN BONE-MARROW AND SPLEEN USING IMMUNOFLUORESCENCE AND WRIGHTS GIEMSA
    KRISHNA, G
    URDA, G
    THEISS, JC
    MUTATION RESEARCH, 1994, 323 (1-2): : 11 - 20
  • [2] DIMETHYLNITROSAMINE-INDUCED MICRONUCLEUS FORMATION IN MOUSE BONE-MARROW AND SPLEEN
    KRISHNA, G
    KROPKO, ML
    THEISS, JC
    MUTATION RESEARCH, 1990, 242 (04): : 345 - 351
  • [3] COMPARISON OF SINGLE AND MULTIPLE TREATMENT REGIMENS IN THE MOUSE BONE-MARROW MICRONUCLEUS ASSAY FOR HYDROQUINONE (HQ) AND CYCLOPHOSPHAMIDE (CP)
    ADLER, ID
    KLIESCH, U
    MUTATION RESEARCH, 1990, 234 (3-4): : 115 - 123
  • [4] Evaluation of a multi-endpoint assay in rats, combining the bone-marrow micronucleus test, the Comet assay and the flow-cytometric peripheral blood micronucleus test
    Bowen, Damian E.
    Whitwell, James H.
    Lillford, Lucinda
    Henderson, Debbie
    Kidd, Darren
    McGarry, Sarah
    Pearce, Gareth
    Beevers, Carol
    Kirkland, David J.
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2011, 722 (01) : 7 - 19