FAST SPIN-ECHO IMAGING OF THE ABDOMEN DURING BREATH-HOLDING - AN ALTERNATIVE TO RASE AND OTHER FAST IMAGING TECHNIQUES

被引:4
|
作者
NELSON, RC [1 ]
CHEZMAR, JL [1 ]
机构
[1] EMORY UNIV,SCH MED,DEPT RADIOL,ATLANTA,GA 30322
来源
GASTROINTESTINAL RADIOLOGY | 1992年 / 17卷 / 04期
关键词
ABDOMEN; MR STUDIES; MAGNETIC RESONANCE; PULSE SEQUENCES; TECHNOLOGY; RAPID IMAGING;
D O I
10.1007/BF01888573
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We have developed a rapidly acquired T1-weighted spin-echo pulse sequence that uses gradient echo-like parameters of TR 70 ms, TE 10 ms, NEX-1 (SE 70/10/1) with large pulse angles, and presaturation. This sequence yields two images of the abdomen during a comfortable breath-hold of 9 s. Preliminary phantom studies with this sequence demonstrated that peak signal-to-noise ratios occurred at pulse angles of 120-degrees and 135-degrees. Compared to this rapidly acquired sequence, a conventional T1-weighted spin-echo sequence of TR 140 ms, TE 10 ms, NEX-4 demonstrated 2.8 times the signal-to-noise ratio, 2.6 times the liver-spleen contrast-to-noise ratio but only 1.6 times the contrast-to-artifact ratio. When normalized for the imaging time, however, there was little difference in the signal-to-noise and contrast-to-noise ratios, although the SE 70/10/1 demonstrated 2.0 times the contrast-to-artifact ratio. We conclude that for abdominal imaging the SE 70/10/1 is an excellent alternative to RASE and other fast imaging techniques, and, although there are inherently low signal-to-noise ratios, it may be particularly useful when coupled with a paramagnetic contrast agent.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 50 条
  • [21] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [22] Incidental magnetization transfer contrast in fast spin-echo imaging of cartilage
    Yao, L
    Gentili, A
    Thomas, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) : 180 - 184
  • [23] MRI IMAGING OF THE LIVER AT 1,5 TESLA - VALUE OF T1-WEIGHTED IMAGING WITH A FAST MULTISLICE GRADIENT-ECHO SEQUENCE DURING BREATH-HOLDING
    TAUPITZ, M
    HAMM, B
    SPEIDEL, A
    BRANDING, G
    WOLF, KJ
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (02): : 135 - 141
  • [24] Volume (three-dimensional) fast spin-echo imaging of the lumbar spine
    Maldjian, C
    Adam, RJ
    Akhtar, N
    Maldjian, JA
    Bonakdarpour, A
    Boyko, O
    ACADEMIC RADIOLOGY, 1999, 6 (06) : 339 - 342
  • [25] RAPID MR IMAGING OF THE PEDIATRIC BRAIN USING THE FAST SPIN-ECHO TECHNIQUE
    AHN, SS
    MANTELLO, MT
    JONES, KM
    MULKERN, RV
    MELKI, PS
    HIGUCHI, N
    BARNES, PD
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1992, 13 (04) : 1169 - 1177
  • [26] DIAGNOSIS OF MESIAL TEMPORAL SCLEROSIS WITH CONVENTIONAL VERSUS FAST SPIN-ECHO MR-IMAGING
    JACK, CR
    KRECKE, KN
    LUETMER, PH
    CASCINO, GD
    SHARBROUGH, FW
    OBRIEN, PC
    PARISI, JE
    RADIOLOGY, 1994, 192 (01) : 123 - 127
  • [27] ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING
    LOW, RN
    FRANCIS, IR
    SIGETI, JS
    FOO, TKF
    RADIOLOGY, 1993, 186 (03) : 803 - 811
  • [28] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859
  • [29] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184
  • [30] MULTICOIL HIGH-RESOLUTION FAST SPIN-ECHO MR IMAGING OF THE FEMALE PELVIS
    SMITH, RC
    REINHOLD, C
    MCCAULEY, TR
    LANGE, RC
    CONSTABLE, RT
    KIER, R
    MCCARTHY, S
    RADIOLOGY, 1992, 184 (03) : 671 - 675