MIXTURE DESIGNS APPLIED TO THE STUDY OF THE LIQUID-CHROMATOGRAPHIC SEPARATION OF L-PHENYLALANINE, L-TYROSINE AND L-TRYPTOPHAN

被引:5
|
作者
PALASOTA, JM [1 ]
DEMING, SN [1 ]
机构
[1] UNIV HOUSTON,DEPT CHEM,4800 CALHOUN RD,HOUSTON,TX 77204
关键词
LIQUID CHROMATOGRAPHY; OPTIMIZATION METHODS; MIXTURE DESIGN; PHENYLALANINE; TRYPTOPHAN; TYROSINE;
D O I
10.1016/0003-2670(92)80088-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mixture designs were used to improve the separation of L-phenylalanine, L-tyrosine and L-tryptophan on a C18 bonded stationary phase. The pH of the mobile phase and retention time of each amino acid were measured for 35 mobile phase formulations containing various concentrations of H3PO4, NaH2PO4, NaClO4, sodium 1-octane-sulfonate and methanol. A non-linear six-parameter model was used to describe the measured pH as a function of the eluent composition with a standard error of estimate of 0.10 pH unit. A different non-linear ten-parameter model was used to describe the measured retention time as a function of eluent composition for each of the three amino acids with a standard error of estimate of 0.08 min. This last model was then used to predict the composition for which the separation would be optimum. The optimum separation was confirmed experimentally.
引用
收藏
页码:13 / 38
页数:26
相关论文
共 50 条
  • [1] Transport of aromatic amino acids L-tryptophan, L-tyrosine, and L-phenylalanine by the organic anion transporting polypeptide (OATP) 3A1
    Surrer, Daniela B.
    Schusser, Sarah
    Konig, Jorg
    Fromm, Martin F.
    Gessner, Arne
    FEBS JOURNAL, 2024, 291 (21) : 4732 - 4743
  • [2] Ion-selective electrodes based on L-tryptophan and L-tyrosine
    Moriuchi-Kawakami, Takayo
    Tokunaga, Yu
    Yamamoto, Hiroyuki
    Shibutani, Yasuhiko
    TALANTA, 2012, 94 : 99 - 103
  • [3] Spectroscopic characterization of Cu(II) complex of L-phenylalanine and D,L-tryptophan
    Altun, Oezlen
    Bilcen, Selin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2010, 75 (02) : 789 - 793
  • [4] Direct electrochemical reduction of graphene oxide and its application to determination of L-tryptophan and L-tyrosine
    Deng, Ke-Qin
    Zhou, Jian-hong
    Li, Xiao-Fang
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 101 : 183 - 188
  • [5] Electrochemical determination of L-Tryptophan, L-Tyrosine and L-Cysteine using electrospun carbon nanofibers modified electrode
    Tang, Xiaofeng
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    TALANTA, 2010, 80 (05) : 2182 - 2186
  • [6] Development of novel hybrid hydroxyapatite-based sensors for the ultrasensitive detection of L-tryptophan and L-tyrosine
    Bouazzi, Dorsaf
    Cherif, Imen
    Lefi, Nizar
    Caccamo, Maria Teresa
    Magazu, Salvatore
    Barhoumi, Houcine
    Ayachi, Sahbi
    Nunzi, Jean Michel
    Laghzizil, Abdelaziz
    Badraoui, Bechir
    MICROCHEMICAL JOURNAL, 2024, 207
  • [7] EFFECTS OF INTRACELLULAR ADMINISTRATION OF L-TYROSINE AND L-PHENYLALANINE ON VOLTAGE-OPERATED CALCIUM CONDUCTANCE IN PC12 PHEOCHROMOCYTOMA CELLS
    KOSTYUK, PG
    MARTYNYUK, AE
    POGORELAYA, NC
    BRAIN RESEARCH, 1991, 550 (01) : 11 - 14
  • [8] Electrochemical behavior and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with single-walled carbon nanohorns
    Zhu, Shuyun
    Zhang, Jiao
    Zhao, Xian-en
    Wang, Hua
    Xu, Guobao
    You, Jinmao
    MICROCHIMICA ACTA, 2014, 181 (3-4) : 445 - 451
  • [9] Electrochemical behavior and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with single-walled carbon nanohorns
    Shuyun Zhu
    Jiao Zhang
    Xian-en Zhao
    Hua Wang
    Guobao Xu
    Jinmao You
    Microchimica Acta, 2014, 181 : 445 - 451
  • [10] Electrochemistry and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with a Nafion/TiO2-graphene composite film
    Fan, Yang
    Liu, Jin-Hang
    Lu, Hai-Ting
    Zhang, Qin
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 241 - 247