COMPARISON OF NONSPECIFIC RADIOIMMUNOASSAY, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, AND FLUORESCENCE POLARIZATION IMMUNOASSAY FOR CYCLOSPORINE MONITORING IN RENAL-TRANSPLANTATION

被引:8
|
作者
LEE, SF
YANG, WC
SHANN, TY
LUI, WY
WANG, RB
机构
[1] VET GEN HOSP TAIPEI,DIV NEPHROL,TAIPEI 11217,TAIWAN
[2] VET GEN HOSP TAIPEI,DEPT GEN SURG,TAIPEI 11217,TAIWAN
关键词
CYCLOSPORINE; RADIOIMMUNOASSAY; HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY; FLUORESCENCE POLARIZATION IMMUNOASSAY;
D O I
10.1097/00007691-199103000-00011
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Three methods, i.e., nonspecific radioimmunoassay (RIA; Incstar), fluorescence polarization immunoassay (FPIA; TDx Abbott), and high-performance liquid chromatography (HPLC), have been used for monitoring cyclosporine blood levels in renal transplantation patients. The levels obtained from 135 samples showed a modest correlation between RIA and HPLC, FPIA and HPLC, RIA and FRIA. The mean ratios of RIA to HPLC, FPIA to HPLC, and RIA to FPIA were 2.96, 4.14, and 0.73. The significant variations in cyclosporine levels result from the cross-reaction of antibody with some cyclosporine metabolites, by which these two methods often overestimate the true blood cyclosporine level. HPLC is a more effective and reliable method for pharmacokinetic studies and blood level monitoring of cyclosporine in clinical practice.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 50 条
  • [41] DETECTION OF DIGOXIN, DIGITOXIN, THEIR CARDIOACTIVE METABOLITES AND DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY RADIOIMMUNOASSAY
    PLUM, J
    DALDRUP, T
    JOURNAL OF CHROMATOGRAPHY, 1986, 377 : 221 - 231
  • [42] FLUORESCENCE DERIVITIZATION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OHKURA, Y
    NOHTA, H
    ADVANCES IN CHROMATOGRAPHY, 1989, 29 : 221 - 258
  • [43] FLUORESCENCE DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LINGEMAN, H
    UNDERBERG, WJM
    TAKADATE, A
    HULSHOFF, A
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (05): : 789 - 874
  • [44] IS THE MONOCLONAL FLUORESCENCE POLARIZATION IMMUNOASSAY FOR CYCLOSPORINE SPECIFIC - COMPARISON WITH SPECIFIC RADIOIMMUNOASSAY
    ARMIJO, JA
    NAVARRO, FA
    DECOS, MA
    THERAPEUTIC DRUG MONITORING, 1992, 14 (04) : 333 - 338
  • [45] WHOLE-BLOOD CYCLOSPORINE-A - COMPARISON OF A MONOCLONAL-ANTIBODY RADIOIMMUNOASSAY WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC)
    BERK, L
    BEIERLE, F
    WEBB, G
    IMPERIO, N
    EBY, W
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1100 - 1100
  • [46] COMPARISON OF HIGH-PRESSURE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE POLARIZATION IMMUNOASSAY TO ASSESS QUINIDINE PHARMACOKINETICS
    BOTTORFF, MB
    LALONDE, RL
    STRAUGHN, AB
    BIOPHARMACEUTICS & DRUG DISPOSITION, 1987, 8 (03) : 213 - 221
  • [47] Comparison of fluorescence polarization immunoassay and high-performance liquid chromatography methods for assay of teicoplanin:: can correlation be improved?
    Davani, S
    Bérard, M
    Royer, B
    Kantelip, JP
    Muret, P
    PATHOLOGIE BIOLOGIE, 2004, 52 (10): : 584 - 588
  • [48] CYCLOSPORINE KINETICS IN RENAL-TRANSPLANT PATIENTS AS ASSESSED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND RADIOIMMUNOASSAY USING MONOCLONAL AND POLYCLONAL ANTIBODIES
    SPECK, RF
    FREY, FJ
    FREY, BM
    TRANSPLANTATION, 1989, 47 (05) : 802 - 806
  • [49] USE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE VALIDATION OF RADIOIMMUNOASSAY FOR CHLORPROMAZINE
    GRASSI, J
    NEVERS, MC
    PRADELLES, P
    PATHOLOGIE BIOLOGIE, 1981, 29 (06): : 375 - 377
  • [50] COMPARISON OF FLUORESCENCE POLARIZATION IMMUNOASSAY (ABBOTT-TDX) AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) FOR THE QUANTITATIVE-DETERMINATION OF TOTAL AND FREE PHENYTOIN
    MAAS, MC
    KARCHER, RE
    EPSTEIN, E
    KIECHLE, FL
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1253 - 1253