EFFECT OF MACHINE PARAMETERS ON VARIANCE DISPLAY IN DOPPLER COLOR FLOW MAPPING

被引:9
|
作者
UTSUNOMIYA, T [1 ]
OGAWA, T [1 ]
KING, SW [1 ]
SUNADA, E [1 ]
MOORE, GW [1 ]
HENRY, WL [1 ]
GARDIN, JM [1 ]
机构
[1] UNIV CALIF IRVINE,CALIF COLL MED,DEPT MED,DIV CARDIOL,IRVINE,CA 92717
关键词
D O I
10.1016/0002-8703(90)90254-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In color Doppler flow studies, "variance" is an important display modality for diagnosing stenotic, regurgitant, and shunt lesions. Variance, a mathematical calculation based on the variation in the Doppler signal frequencies, has been reported to reflect the degree of flow disturbance. A wide-band pulsed Doppler spectrum results in a larger degree of variance. It has been suggested that variance area (green color or mosaic area) might provide useful quantitative information regarding the severity of stenotic, regurgitant, and shunt lesions. Since ultrasound machine settings may affect the color Doppler variance image, we evaluated in 101 free jet experiments the effect of packet size (eight versus four samples per line), pulse repetition frequency (3.9 versus 5.2 kHz), frame rate (11 versus 22 frames per second), system gain (+15 dB versus -15 dB), transmit power (high versus low), and moving target indicator (MTI) filter setting (high versus low) on variance display. The variance area was planimetered using an image analysis computer. The following machine parameters were inversely correlated with variance area: (1) packet size (p < 0.01), (2) pulse repetition frequency (p < 0.001), and (3) frame rate (p < 0.05). Both system gain (p < 0.001) and wall filter setting (p < 0.01) showed a direct correlation with variance area. We conclude that machine factors must be standardized in evaluating stenotic, regurgitant, and shunt lesions by color Doppler variance display imaging. © 1990.
引用
收藏
页码:1395 / 1402
页数:8
相关论文
共 50 条
  • [41] ECHO CONTRAST AGENTS IMPROVE FLOW DISPLAY OF COLOR DOPPLER - INVITRO STUDIES
    VONBIBRA, H
    STEMPFLE, HU
    POLL, A
    SCHLIEF, R
    EMSLANDER, H
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1991, 8 (05): : 533 - 540
  • [42] INVITRO STUDIES OF VARIANCE (TURBULENCE) INDICATORS IN COLOR FLOW MAPPING DOPPLER SYSTEMS - QUANTITATIVE COMPUTER-ANALYSIS OF RGB DIGITIZED FLOW MAP IMAGES
    TAMURA, T
    ELIAS, W
    GUNDAY, E
    MCMILLAN, S
    JIMOH, A
    YOGANATHAN, A
    CHUNG, KJ
    CIRCULATION, 1987, 76 (04) : 141 - 141
  • [43] Estimation of flow velocity vectorial profile by ultrasound color Doppler mapping
    Adam, DR
    Givony, D
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 829 - 831
  • [44] ASSESSMENT OF MITRAL REGURGITATION BY BIPLANE TRANSESOPHAGEAL COLOR DOPPLER FLOW MAPPING
    YOSHIDA, K
    YOSHIKAWA, J
    YAMAURA, Y
    HOZUMI, T
    AKASAKA, T
    FUKAYA, T
    CIRCULATION, 1990, 82 (04) : 1121 - 1126
  • [45] RUPTURED ANEURYSM OF SINUS OF VALSALVA - RECOGNITION BY DOPPLER COLOR FLOW MAPPING
    CHIA, BL
    EE, BK
    CHOO, MH
    YAN, PC
    AMERICAN HEART JOURNAL, 1988, 115 (03) : 686 - 688
  • [46] NONLINEARITY OF DOPPLER COLOR-FLOW MAPPING MEASUREMENTS FOR VALVULAR REGURGITATION
    BOMMER, WJ
    REBECK, K
    MUCCI, L
    FEHRENBACHER, G
    CIRCULATION, 1987, 76 (04) : 139 - 139
  • [47] PRENATAL-DIAGNOSIS OF AORTIC ATRESIA BY COLOR DOPPLER FLOW MAPPING
    GEMBRUCH, U
    CHATTERJEE, M
    BALD, R
    ELDERING, G
    GOCKE, H
    URBAN, AE
    HANSMANN, M
    PRENATAL DIAGNOSIS, 1990, 10 (04) : 211 - 217
  • [48] ANTENATAL DOPPLER COLOR FLOW MAPPING OF ARTERIOVENOUS MALFORMATION OF THE VEIN OF GALEN
    HATA, T
    HATA, K
    SENOH, D
    AOKI, S
    TAKAMIYA, O
    YAMAMOTO, K
    KITAO, M
    JOURNAL OF CARDIOVASCULAR ULTRASONOGRAPHY, 1988, 7 (04): : 301 - 303
  • [49] INTRAOPERATIVE DETECTION AND QUANTITATION OF MITRAL REGURGITATION BY DOPPLER COLOR FLOW MAPPING
    CZER, LSC
    MAURER, G
    DEROBERTIS, M
    BOLGER, AF
    GRAY, RJ
    MATLOFF, JM
    CLINICAL RESEARCH, 1987, 35 (03): : A272 - A272
  • [50] EFFECT OF FLOW-RATE AND ORIFICE SIZE ON COLOR DOPPLER FLOW MAPPING STUDIES OF REGURGITANT JETS IN AN INVITRO MODEL
    SIMPSON, IA
    TAMURA, T
    VALDESCRUZ, LM
    MURILLO, A
    SAHN, DJ
    CIRCULATION, 1987, 76 (04) : 140 - 140