EFFECT OF MACHINE PARAMETERS ON VARIANCE DISPLAY IN DOPPLER COLOR FLOW MAPPING

被引:9
|
作者
UTSUNOMIYA, T [1 ]
OGAWA, T [1 ]
KING, SW [1 ]
SUNADA, E [1 ]
MOORE, GW [1 ]
HENRY, WL [1 ]
GARDIN, JM [1 ]
机构
[1] UNIV CALIF IRVINE,CALIF COLL MED,DEPT MED,DIV CARDIOL,IRVINE,CA 92717
关键词
D O I
10.1016/0002-8703(90)90254-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In color Doppler flow studies, "variance" is an important display modality for diagnosing stenotic, regurgitant, and shunt lesions. Variance, a mathematical calculation based on the variation in the Doppler signal frequencies, has been reported to reflect the degree of flow disturbance. A wide-band pulsed Doppler spectrum results in a larger degree of variance. It has been suggested that variance area (green color or mosaic area) might provide useful quantitative information regarding the severity of stenotic, regurgitant, and shunt lesions. Since ultrasound machine settings may affect the color Doppler variance image, we evaluated in 101 free jet experiments the effect of packet size (eight versus four samples per line), pulse repetition frequency (3.9 versus 5.2 kHz), frame rate (11 versus 22 frames per second), system gain (+15 dB versus -15 dB), transmit power (high versus low), and moving target indicator (MTI) filter setting (high versus low) on variance display. The variance area was planimetered using an image analysis computer. The following machine parameters were inversely correlated with variance area: (1) packet size (p < 0.01), (2) pulse repetition frequency (p < 0.001), and (3) frame rate (p < 0.05). Both system gain (p < 0.001) and wall filter setting (p < 0.01) showed a direct correlation with variance area. We conclude that machine factors must be standardized in evaluating stenotic, regurgitant, and shunt lesions by color Doppler variance display imaging. © 1990.
引用
收藏
页码:1395 / 1402
页数:8
相关论文
共 50 条
  • [1] CLINICAL-SIGNIFICANCE OF POWER DISPLAY IN DOPPLER COLOR FLOW MAPPING
    KAMBE, T
    HIBI, N
    IEDA, N
    IIDA, K
    MIYAJIMA, K
    NISHIDA, T
    KOBAYASHI, S
    OKAMOTO, Y
    KAKINUMA, Y
    SAKAMOTO, N
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (08): : 750 - 750
  • [2] DOPPLER COLOR FLOW MAPPING
    SWITZER, DF
    NANDA, NC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03): : 403 - 416
  • [3] COLOR DOPPLER FLOW MAPPING
    SIMPSON, IA
    CAMM, AJ
    BRITISH MEDICAL JOURNAL, 1990, 300 (6716): : 1 - 2
  • [4] DOPPLER ECHOCARDIOGRAPHY AND COLOR FLOW MAPPING
    COPEL, JA
    HOBBINS, JC
    KLEINMAN, CS
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 1991, 18 (04) : 845 - 851
  • [5] INFLUENCE OF THE COANDA EFFECT ON COLOR DOPPLER JET AREA AND COLOR ENCODING - INVITRO STUDIES USING COLOR DOPPLER FLOW MAPPING
    KUNG, C
    MOISES, VA
    SHANDAS, R
    ELKADI, T
    SAHN, DJ
    WEINTRAUB, R
    CIRCULATION, 1992, 85 (01) : 333 - 341
  • [6] DOPPLER COLOR FLOW MAPPING OF THE FETAL HEART
    MAULIK, D
    NANDA, NC
    HSIUNG, MC
    YOUNGBLOOD, JP
    ANGIOLOGY, 1986, 37 (09) : 628 - 632
  • [7] COLOR DOPPLER FLOW MAPPING OF FETAL HEART
    GEMBRUCH, U
    CHATTERJEE, MS
    BALD, R
    REDEL, DA
    HANSMANN, M
    JOURNAL OF PERINATAL MEDICINE, 1991, 19 (1-2) : 27 - 32
  • [8] DOPPLER COLOR FLOW MAPPING OF AN INVASIVE MOLE
    AOKI, S
    HATA, T
    HATA, K
    SENOH, D
    MIYAKO, J
    TAKAMIYA, O
    IWANARI, O
    KITAO, M
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1989, 27 (01) : 52 - 54
  • [9] COMPARISON OF DOPPLER COLOR FLOW MAPPING PARAMETERS FOR ASSESSING THE SEVERITY OF AORTIC-VALVE REGURGITATION
    HENNEKE, KH
    DENNIG, K
    DACIAN, S
    RUDOLPH, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 : 114 - 114
  • [10] DOPPLER COLOR FLOW MAPPING - UTILITY IN VALVULAR REGURGITATION
    YOCK, PG
    SEGAL, J
    TEIRSTEIN, PS
    SCHNITTGER, I
    POPP, RL
    CIRCULATION, 1984, 70 (04) : 38 - 38