RESONANCE IONIZATION MASS-SPECTROSCOPY OF NEPTUNIUM

被引:0
|
作者
SATTELBERGER, P [1 ]
DEISSENBERGER, R [1 ]
HERRMANN, G [1 ]
RIEGEL, J [1 ]
RIMKE, H [1 ]
TRAUTMANN, N [1 ]
AMES, F [1 ]
KLUGE, HJ [1 ]
机构
[1] UNIV MAINZ,INST PHYS,W-6500 MAINZ,GERMANY
来源
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For ecological studies of 237Np resonance ionization mass-spectroscopy has been explored. The experimental set-up consists of three tunable dye lasers pumped by two pulsed copper vapour lasers and a time-of-flight spectrometer. Several excitation schemes have been studied. For two schemes autoionizing levels could be observed. The hyperfine structure splitting of the resonance lines of the first and second excitation step have been investigated. The available laser powers were sufficient to saturate the first two excitation steps but not the ionization step. Without having optimum conditions, a detection limit of less-than-or-equal-to 10(10) atoms could be reached.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [11] CHEMICAL IONIZATION MASS-SPECTROSCOPY OF LIGNINS
    METZGER, J
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 295 (01): : 45 - 46
  • [12] ISOTOPE RATIO BIASES IN RESONANCE IONIZATION MASS-SPECTROSCOPY DUE TO POPULATION TRAPPING
    WHITTEN, WB
    RAMSEY, JM
    APPLIED SPECTROSCOPY, 1990, 44 (07) : 1188 - 1192
  • [13] ASPECTS OF TRACE ANALYSIS USING RESONANCE IONIZATION MASS-SPECTROSCOPY AND SOME APPLICATIONS
    LEDINGHAM, KWD
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1991, (113): : 141 - 158
  • [14] RESONANCE IONIZATION MASS-SPECTROSCOPY (RIMS) FOR NUCLEAR-RESEARCH AND TRACE ANALYSIS
    KLUGE, HJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 60 - NUCL
  • [15] RESONANCE IONIZATION MASS-SPECTROSCOPY OF PLUTONIUM WITH A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    URBAN, FJ
    DEISSENBERGER, R
    HERRMANN, G
    KOHLER, S
    RIEGEL, J
    TRAUTMANN, N
    WENDELER, H
    ALBUS, F
    AMES, F
    KLUGE, HJ
    KRASS, S
    SCHEERER, F
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (128): : 233 - 236
  • [16] IDENTIFICATION OF DEPSIPEPTIDES BY CHEMICAL IONIZATION MASS-SPECTROSCOPY
    DAS, BC
    VARENNE, P
    TAYLOR, A
    JOURNAL OF ANTIBIOTICS, 1979, 32 (06): : 569 - 574
  • [17] IDENTIFICATION OF DRUGS BY CHEMICAL IONIZATION MASS-SPECTROSCOPY
    SAFERSTEIN, R
    CHAO, JM
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1973, 56 (05): : 1234 - 1237
  • [18] DETERMINATION OF BENZALKONIUM CHLORIDE BY CHEMICAL IONIZATION MASS-SPECTROSCOPY
    DAOUD, NN
    CROOKS, PA
    SPEAK, R
    GILBERT, P
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (03) : 290 - 292
  • [19] MULTI-PHOTON IONIZATION MASS-SPECTROSCOPY OF ACETALDEHYDE
    FISANICK, GJ
    EICHELBERGER, TS
    HEATH, BA
    ROBIN, MB
    JOURNAL OF CHEMICAL PHYSICS, 1980, 72 (10): : 5571 - 5580
  • [20] ANALYSIS OF EXPLOSIVES USING CHEMICAL IONIZATION MASS-SPECTROSCOPY
    PATE, CT
    MACH, MH
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1978, 26 (03): : 267 - 277