Performance Evaluation of Heat Exchangers in a Polyethylene Plant

被引:0
|
作者
Lebele-Alawa, Barinaadaa Thaddeus [1 ]
Ohia, Innocent Okpara [1 ]
机构
[1] Rivers State Univ Sci & Technol, Dept Mech Engn, Port Harcourt, Nigeria
关键词
heat-exchanger; heat; performance; energy;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper evaluates the performance of three heat exchanger units (2-E-2301, 3-E-901 and 3-E-401) in a polyethylene plant. Steady state monitoring and direct collection of data from the equipment in the plant were performed and the data were analyzed by using energy equations to determine the overall heat transfer coefficient, heat duty, temperature and pressure range of hot and cold fluids, capacity ratio and effectiveness. The results show that for 2-E-2301, the overall heat transfer coefficient is over 50 percent less than the design figure and the heat duty is over 75 percent than the design figure. For the 3-E-901 the heat duty and the overall heat transfer are over 75 percent less than the design figure which was traceable to fouling. This affected the effectiveness, capacity ratio and temperature range of the hot and cold fluid. For the 3-E-401, the heat duty was found to be within the limit of design figure. The temperature difference in the hot fluid side and the capacity ratio were within the limits of the design figure. Thus, the results show qualitative performance evaluation of the heat exchangers.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] Polyethylene heat exchangers
    不详
    TCE, 2010, (826): : 17 - 17
  • [2] PERFORMANCE OF REFRIGERATING PLANT WITH EFFICIENT HEAT EXCHANGERS
    Zakirov, S. G.
    Karimov, K. F.
    Azizov, D. Kh.
    Maslov, A. V.
    Nurmatov, T. B.
    CHEMICAL AND PETROLEUM ENGINEERING, 2008, 44 (3-4) : 198 - 201
  • [3] Performance and Economic Evaluation of Ground Heat Exchangers
    Yoon, Seok
    Cho, Nam Hyun
    Go, Gyu Hyun
    Lee, Seung Rae
    CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 1913 - +
  • [4] Performance evaluation of wire mesh heat exchangers
    Sayed, M. A.
    Hussin, A. M. T. A. ELdein
    Mahmoud, N. A.
    Aboelsoud, W.
    APPLIED THERMAL ENGINEERING, 2020, 169
  • [5] Performance based NDE program for balance of plant heat exchangers
    Krzywosz, K
    Cagle, L
    NDE IN THE NUCLEAR AND PRESSURE VESSEL INDUSTRIES, 1997, : 143 - 146
  • [6] Fatigue performance evaluation of plate and shell heat exchangers
    Martins, G. S. M.
    da Silva, R. P. P. D.
    Beckedorff, L.
    Monteiro, A. S.
    de Paiva, K., V
    Oliveira, J. L. G.
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2020, 188 (188)
  • [7] Performance Evaluation of Wire Cloth Micro Heat Exchangers
    Fugmann, Hannes
    Martens, Sebastian
    Balzer, Richard
    Brenner, Martin
    Schnabel, Lena
    Mehring, Carsten
    ENERGIES, 2020, 13 (03)
  • [8] Evaluation of polyethylene and steel heat exchangers of ground source heat pump systems based on seasonal performance comparison and life cycle assessment
    Ren, Chen
    Deng, Yelin
    Cao, Shi-Jie
    ENERGY AND BUILDINGS, 2018, 162 : 54 - 64
  • [9] Heat exchangers for LNG plant
    Civil Engineers Australia, 2003, 75 (07): : 28 - 29
  • [10] Thermal performance evaluation of heat pipe heat exchangers under natural convection
    , Pune University Campus, Maharashtra, India
    不详
    Int. J. Heat Exch., 2006, 1 (103-122):