BIOCOMPATIBILITY STUDY OF AS-POLYMERIZED POLY(L-LACTIDE) IN RATS USING A CAGE IMPLANT SYSTEM

被引:31
作者
BERGSMA, JE
ROZEMA, FR
BOS, RRM
BOERING, G
DEBRUIJN, WC
PENNINGS, AJ
机构
[1] ERASMUS UNIV ROTTERDAM,INST CLIN PATHOL 1,AEM UNIT,ROTTERDAM,NETHERLANDS
[2] UNIV GRONINGEN,DEPT POLYMER CHEM,9747 AG GRONINGEN,NETHERLANDS
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1995年 / 29卷 / 02期
关键词
D O I
10.1002/jbm.820290206
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate the biocompatibility of in vitro predegraded as polymerized poly(L-lactide) (PLLA), a cage implant system was used to investigate white cell and enzyme concentrations with time. The use of a cage permits in a serial fashion a quantitative and qualitative measurement of exudate components formed around an implant. Subcutaneously in rats, caped cages manufactured from stainless-steel mesh were implanted with in vitro predegraded, as-polymerized PLLA, as-polymerized PLLA cylinders, and empty cages serving as controls. In vitro predegradation was used to simulate the degradation products of long-term in vitro degradation. Predegraded PLLA particles were obtained by in vitro hydrolysis at elevated temperatures. The first 7 days of implantation were characterized by an acute inflammatory reaction; the exudate extracted from the cages showed predominantly neutrophils for all types of implants. After day 7, there was a more chronic inflammatory reaction with predominantly macrophages and lymphocytes. There were no significant differences in the total leukocyte concentration or macrophage concentration for any of the cages in the period from 10-21 days. Extracellular enzyme activity also did not show any significant differences among the three types of cages. A possible explanation for the absence of any significant differences could be that the in vitro predegraded particles were sieved before implantation, thus eliminating all small particles (< 70 mu m) that are probably mandatory to provoke an increased cellular reaction. (C) 1995 John Wiley and Sons, Inc.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 38 条
  • [1] FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES
    BERGSMA, EJ
    ROZEMA, FR
    BOS, RRM
    DEBRUIJN, WC
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) : 666 - 670
  • [2] BERGSMA JE, IN PRESS BIOMATERIAL
  • [3] DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS
    BOS, RRM
    ROZEMA, FR
    BOERING, G
    NIJENHUIS, AJ
    PENNINGS, AJ
    VERWEY, AB
    NIEUWENHUIS, P
    JANSEN, HWB
    [J]. BIOMATERIALS, 1991, 12 (01) : 32 - 36
  • [4] RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES
    BOS, RRM
    BOERING, G
    ROZEMA, FR
    LEENSLAG, JW
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) : 751 - 753
  • [5] BIO-ABSORBABLE PLATES AND SCREWS FOR INTERNAL-FIXATION OF MANDIBULAR FRACTURES - A STUDY IN 6 DOGS
    BOS, RRM
    ROZEMA, FR
    BOERING, G
    NIJENHUIS, AJ
    PENNINGS, AJ
    VERWEY, AB
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 18 (06) : 365 - 369
  • [6] BOS RRM, 1987, BR J ORAL MAXILLOFAC, V27, P467
  • [7] BOSTMAN O, 1987, J BONE JT SURG BR B, V17, P706
  • [8] ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES
    BOSTMAN, OM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) : 148 - 153
  • [9] RESORPTION RATE, ROUTE OF ELIMINATION, AND ULTRASTRUCTURE OF IMPLANT SITE OF POLYLACTIC ACID IN ABDOMINAL-WALL OF RAT
    BRADY, JM
    CUTRIGHT, DE
    MILLER, RA
    BATTISTONE, GC
    HUNSUCK, EE
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (02): : 155 - 166
  • [10] CHAWLA AS, 1985, BIOMAT MED DEV ARTIF, V19, P153