REVERSE-PHASE LIQUID-CHROMATOGRAPHY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM MASS-SPECTROMETRY IN THE ANALYSIS OF PEPTIDES

被引:20
|
作者
STACEY, CC [1 ]
KRUPPA, GH [1 ]
WATSON, CH [1 ]
WRONKA, J [1 ]
LAUKIEN, FH [1 ]
BANKS, JF [1 ]
WHITEHOUSE, CM [1 ]
机构
[1] ANALYT BRANFORD,BRANFORD,CT 06405
关键词
D O I
10.1002/rcm.1290080704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization (ESI) in combination with Fourier-transform mass spectrometry (FTMS) gives both highly accurate mass analysis of peptides with external calibration and high resolution for charge-state determination of an ion from the naturally occurring isotopic peaks. Liquid chromatographic (LC) separation of peptides is important for the analysis of complex mixtures. High-resolution, high accuracy measurement of the molecular ions of the mix of peptides has been achieved with LC/ESI-FTMS. Examples are given to show both the reproducibility of mass accuracy over replicate analyses and to show the utility of broadband analysis of a gradient separation of peptides. The high mass accuracy and resolution of FTMS was uncompromised for the direct analysis of chromatography peaks.
引用
收藏
页码:513 / 516
页数:4
相关论文
共 50 条
  • [41] COLLISION-ACTIVATED DISSOCIATION OF LARGE BIOMOLECULES USING ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON MASS-SPECTROMETRY
    WU, Q
    BAKHTIAR, R
    VANORDEN, S
    HOFSTADLER, SA
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 97 - ANYL
  • [42] MULTIPHOTON IONIZATION DETECTED BY FOURIER-TRANSFORM MASS-SPECTROMETRY
    IRION, MP
    BOWERS, WD
    HUNTER, RL
    ROWLAND, FS
    MCIVER, RT
    CHEMICAL PHYSICS LETTERS, 1982, 93 (04) : 375 - 379
  • [43] THE USE OF ELECTROSPRAY MASS-SPECTROMETRY WITH LIQUID-CHROMATOGRAPHY
    HENION, J
    CONBOY, JC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 150 - ANYL
  • [44] ELECTROSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF GINSENOSIDES
    VANBREEMEN, RB
    HUANG, CR
    LU, ZZ
    RIMANDO, A
    FONG, HHS
    FITZLOFF, JF
    ANALYTICAL CHEMISTRY, 1995, 67 (21) : 3985 - 3989
  • [45] THE IDENTIFICATION OF SERUM TUFTSIN BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND MASS-SPECTROMETRY
    NAIM, JO
    DESIDERIO, DM
    TRIMBLE, J
    HINSHAW, JR
    ANALYTICAL BIOCHEMISTRY, 1987, 164 (01) : 221 - 226
  • [46] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY COUPLED WITH SIZE-EXCLUSION CHROMATOGRAPHY
    PROKAI, L
    SIMONSICK, WJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (09) : 853 - 856
  • [47] SUBUNIT ANALYSIS OF BOVINE CYTOCHROME BC1 BY REVERSE-PHASE HPLC AND DETERMINATION OF THE SUBUNIT MOLECULAR MASSES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    MUSATOV, A
    ROBINSON, NC
    BIOCHEMISTRY, 1994, 33 (35) : 10561 - 10567
  • [48] FOURIER-TRANSFORM MASS-SPECTROMETRY
    WILKINS, CL
    ANALYTICAL CHEMISTRY, 1978, 50 (04) : A493 - &
  • [49] SUPERCRITICAL FLUID CHROMATOGRAPHY FOURIER-TRANSFORM MASS-SPECTROMETRY
    LEE, ED
    HENION, JD
    CODY, RB
    KINSINGER, JA
    ANALYTICAL CHEMISTRY, 1987, 59 (09) : 1309 - 1312
  • [50] FOURIER-TRANSFORM MASS-SPECTROMETRY
    KOSTER, C
    KAHR, MS
    CASTORO, JA
    WILKINS, CL
    MASS SPECTROMETRY REVIEWS, 1992, 11 (06) : 495 - 512