STRESS-CRACKING RESISTANCE OF HIGH-DENSITY POLYETHYLENE GEOMEMBRANES

被引:23
|
作者
HSUAN, YG
KOERNER, RM
LORD, AE
机构
[1] Geosynthetic Res. Inst., Drexel Univ., Philadelphia, PA
[2] Geosynthetic Res. Inst., Drexel Univ., Philadelphia, PA
来源
关键词
D O I
10.1061/(ASCE)0733-9410(1993)119:11(1840)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new index test method, the notched constant tensile load (NCTL) test, for evaluating high-density polyethylene (HDPE) geomembranes regarding stress-cracking resistance is presented in this paper. Eighteen commercially virgin geomembranes and 7 field-exhumed geomembranes were evaluated using the new test. Results show a wide variation in the onset of the transition time. For the 18 virgin geomembranes, the transition times range from 10 hours to 5,000 hours. In addition, all 7 field-exhumed geomembranes, where failure actually occurred, show transition times less than 100 hours. An evaluation of the test results leads to a tentative recommendation that the transition time for an acceptable HDPE geomembrane should be 100 hours or longer. A comparison between the results of NCTL test and the currently used ASTM D 1693 bent-strip test was conducted. It indicates that the bent-strip test cannot adequately evaluate stress cracking resistance, and that the NCTL test is a more critical test in the assessment of such behavior.