A DOUBLE-BLIND COMPARATIVE-STUDY OF THE SAFETY AND EFFICACY OF IOMEPROL IN RENAL INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY

被引:4
|
作者
SIMONETTI, G
GUAZZARONI, M
CARPANESE, L
CANALIS, GC
URIGO, F
机构
[1] University Tor Vergata, S. Eugenio Hospital, 00144 Rome
[2] Department of Radiology, University of Sassari, Sassari
关键词
CONTRAST MEDIA; ANGIOGRAPHY; EFFICACY; TECHNIQUE; DSA;
D O I
10.1016/0720-048X(94)90097-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This randomised, double-blind, parallel group study was to compare the safety, tolerance and diagnostic efficacy of iomeprol and iopamidol, both at an iodine concentration of 150 mgI/ml, in 40 patients with arterial hypertension who required renal intraarterial digital subtraction angiography (IA-DSA) for suspected renovascular stenosis. All patients underwent extensive pre- and post-contrast clinical, instrumental and laboratory controls for safety assessments. The tolerance to the test contrast media was evaluated in terms of discomfort associated with the injection of the test compounds. Image quality was prospectively graded by two independent readers according to a five-point scale as follows: 1, insufficient; 2, sufficient; 3, good; 4, excellent; E, excessive. The quality of vascular opacification in the region of interest was rated as diagnostic in 87.8% of radiographs obtained in the iomeprol group and in 84.5% in the iopamidol group, without significant differences between the two study groups. The results of angiography were always useful for subsequent patient management. The procedure was always well tolerated. There were no clinically significant changes in vital signs, ECG and laboratory parameters during the study in both groups. The results of our study show that iomeprol 150 mgI/ml, and iopamidol 150 mgI/ml are equally effective, well tolerated and safe contrast agents when used for IA-DSA.
引用
收藏
页码:S73 / S76
页数:4
相关论文
共 50 条
  • [1] DOUBLE-BLIND COMPARISON OF SAFETY AND EFFICACY OF IOMEPROL AND IOPAMIDOL IN CAROTID DIGITAL SUBTRACTION ANGIOGRAPHY
    BELTRAMELLO, A
    PIOVAN, E
    ROSTA, L
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 : S67 - S72
  • [2] IODIXANOL IN ABDOMINAL DIGITAL SUBTRACTION ANGIOGRAPHY - A RANDOMIZED, DOUBLE-BLIND, PARALLEL TRIAL WITH IODIXANOL AND IOHEXOL
    SINGH, K
    SUNDGREN, R
    BOLSTAD, B
    BJORK, L
    LIE, M
    ACTA RADIOLOGICA, 1993, 34 (03) : 242 - 245
  • [3] IOMEPROL AND IOPAMIDOL IN CARDIAC ANGIOGRAPHY - A RANDOMIZED, DOUBLE-BLIND, PARALLEL-GROUP COMPARISON
    FATTORI, R
    PIVA, R
    SCHICCHI, F
    PANCRAZI, A
    GABRIELLI, G
    MARZOCCHI, A
    PIOVACCARI, G
    BLANDINI, A
    MAGNANI, B
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 : S61 - S66
  • [4] COMPARATIVE-STUDY BETWEEN ULTRASOUND, COMPUTED-TOMOGRAPHY, INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING IN THE DIFFERENTIATION OF TUMORS OF THE LIVER
    VLACHOS, L
    TRAKADAS, S
    GOULIAMOS, A
    LAZAROU, S
    MOURIKIS, D
    IOANNOU, R
    KALOVIDOURIS, A
    PAPAVASILIOU, C
    GASTROINTESTINAL RADIOLOGY, 1990, 15 (02): : 102 - 106
  • [5] A DOUBLE-BLIND COMPARATIVE-STUDY ON THE CONTRAST QUALITY, TOLERANCE AND SAFETY OF IOVERSOL 300 VERSUS IOHEXOL 300 IN CENTRAL VENOUS ANGIOGRAPHY (CV DSA)
    RIESER, R
    BEINBORN, W
    NEY, N
    ANNALES DE RADIOLOGIE, 1992, 35 (4BIS) : 311 - 314
  • [6] Efficacy, Safety, and Tolerance of Two Types of Intragastric Balloons Placed in Obese Subjects: A Double-Blind Comparative Study
    Luisa De Castro, Maria
    Jose Morales, Maria
    Del Campo, Victor
    Pineda, Juan R.
    Pena, Eduardo
    Sierra, Jose M.
    Jose Arbones, Maria
    Prada, Ignacio R.
    OBESITY SURGERY, 2010, 20 (12) : 1642 - 1646
  • [7] Efficacy, Safety, and Tolerance of Two Types of Intragastric Balloons Placed in Obese Subjects: A Double-Blind Comparative Study
    Maria Luisa De Castro
    María José Morales
    Víctor Del Campo
    Juan R. Pineda
    Eduardo Pena
    José M. Sierra
    María José Arbones
    Ignacio R. Prada
    Obesity Surgery, 2010, 20 : 1642 - 1646
  • [8] Clinical experience with iobitridol 250-300 in digital subtraction angiography - Double-blind randomized studies vs iopromide and iohexol
    Bouard, JC
    Lyonnet, D
    Illes, JP
    BouardMonnier, C
    Rouviere, O
    Pangaud, C
    ACTA RADIOLOGICA, 1996, 37 : 85 - 88
  • [9] A double-blind comparison of the efficacy and safety of milnacipran and fluoxetine in depressed inpatients
    Guelfi, JD
    Ansseau, M
    Corruble, E
    Samuelian, JC
    Tonelli, I
    Tournoux, A
    Pletan, Y
    INTERNATIONAL CLINICAL PSYCHOPHARMACOLOGY, 1998, 13 (03) : 121 - 128
  • [10] Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial
    Achenbach, Stephan
    Paul, Jean-Francois
    Laurent, Francois
    Becker, Hans-Christoph
    Rengo, Marco
    Caudron, Jerome
    Leschka, Sebastian
    Vignaux, Olivier
    Knobloch, Gesine
    Benea, Giorgio
    Schlosser, Thomas
    Andreu, Jordi
    Cabeza, Beatriz
    Jacquier, Alexis
    Souto, Miguel
    Revel, Didier
    Qanadli, Salah Dine
    Cademartiri, Filippo