Heating system with vapour compressor heat pump and vertical U-tube ground heat exchanger

被引:4
|
作者
Hanuszkiewicz-Drapala, Malgorzata [1 ]
Skladzien, Jan [1 ]
机构
[1] Silesian Tech Univ, Inst Thermal Technol, Konarskiego 22, PL-44100 Gliwice, Poland
关键词
Heat pump; Ground heat exchanger; Heating system; Numerical modelling;
D O I
10.2478/v10173-010-0031-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second - the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.
引用
收藏
页码:93 / 110
页数:18
相关论文
共 50 条
  • [1] Numerical Analysis of the Heat Transfer Characteristics of Vertical U-Tube Ground Heat Exchanger Used in Ground Coupled Heat Pump
    Yang, Weibo
    Shi, Mingheng
    Chen, Zhenqian
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1857 - 1864
  • [2] Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump
    Muraya, NK
    ONeal, DL
    Heffington, WM
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 12 - 21
  • [3] Experimental and Simulant Study on Vertical U-Tube Underground Heat Exchanger in Ground-Source Heat Pump
    Gao, Zhen
    Ma, Jinwei
    Yu, Xiaochun
    Zhang, Yu
    Hu, Ning
    Wang, Yanping
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 636 - 641
  • [4] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717
  • [5] Vertical U-tube Ground Heat Exchanger design method research
    Wang, P. Y.
    Tian, H. F.
    Cao, W. W.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 974 - 978
  • [6] Performance analysis of a solar-assisted ground source heat pump with a single vertical U-tube ground heat exchanger
    Adebayo, Philip
    Shor, Roman
    Mohamad, Abdulmajeed
    Wemhoner, Carsten
    Mwesigye, Aggrey
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [7] Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system
    Chen, Jinhua
    Xia, Lei
    Li, Baizhan
    Mmereki, Daniel
    RENEWABLE ENERGY, 2015, 73 : 46 - 54
  • [8] Unified heat transfer model of vertical U-tube heat exchangers for ground source heat pump system
    Zhang, Z.-W. (zwzhang10@126.com), 1600, Tsinghua University (31):
  • [9] Research on Hydraulic Characteristics of U-Tube Heat Exchanger Loop in Ground-Coupled Heat Pump System
    Song, Wei
    Yang, Jiaming
    Zheng, Changjin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3186 - 3193
  • [10] Cumulated energy consumption in a heat pump system using a U-tube ground heat exchanger in a moderate climate
    Remiorz, Leszek
    Hanuszkiewicz-Drapala, Malgorzata
    ENERGY AND BUILDINGS, 2015, 96 : 118 - 127