Reliability of Mid-Upper Arm Circumference Measurements taken by Community Health Nurses

被引:5
|
作者
Saeed, Hibbah Araba [1 ,3 ]
Mogendi, Joseph Birundu [2 ,5 ]
Akparibo, Robert [3 ]
Kolsteren, Patrick [2 ,4 ]
机构
[1] Noguchi Mem Inst Med Res, Accra, Ghana
[2] Univ Ghent, Fac Biosci Engn, B-9000 Ghent, Belgium
[3] Univ Sheffield, Sch Hlth & Related Res, Sheffield, S Yorkshire, England
[4] ITM, Antwerp, Belgium
[5] Mt Kenya Univ, Sch Hlth Sci, Dept Nutr & Dietet, Thika, Kenya
关键词
Mid-upper arm circumference; Reliability; Inter and intra observer variability; Community health nurses;
D O I
10.12944/CRNFSJ.3.1.04
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Mid upper arm circumference-based diagnosis of severe acute malnutrition is seen as very attractive because it is assumed to be simple to use in measuring the arm and also requires a single cut-off without having to compute an index or compare to a reference population. The circumference of the left upper arm measured at the mid-point between the tip of the shoulder and the tip of the elbow is referred to as mid upper arm circumference (MUAC). MUAC was originally used in emergency settings where huge populations had to be screened within a short time. However, in the past few years the development of community therapeutic care of acute malnutrition implied a need for a diagnostic tool. The general objective of the study was to assess the inter-and intra-observer variability in MUAC measurements of under-five children by community health nurses in selected communities of the Northern Region in Ghana. A community-based cohort study was conducted on a convenience sample of 120 community health nurses and nursing students from selected communities in the Northern region of Ghana. Each CHN measured MUAC for four unique children on three consecutive days to assess intra-observer variability. To assess inter-observer variability, 50 independent nursing students took MUAC measures of four children on the same day. Bland Altman plots showed a high degree of agreement of MUAC measures taken repeatedly for three days by the same observers and ICC = 0.993. MUAC measures among observers (inter-observer) and ICC = 0.042 showed a considerable level of variability among different observers. This study showed that MUAC is reliable when repeated measures are taken on children by the same observers, but using different observers for the same children showed a high level of variability.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [21] Mid-upper arm circumference (MUAC) measurement usage among children with disabilities: A systematic review
    Hayes, Julia
    Quiring, Michael
    Kerac, Marko
    Smythe, Tracey
    Tann, Cally J.
    Groce, Nora
    Gultie, Zerihun
    Nyesigomwe, Lydia
    DeLacey, Emily
    NUTRITION AND HEALTH, 2023,
  • [22] Mid-upper arm circumference as an indicator of underweight in adults: a cross-sectional study from Nepal
    Thorup, Lene
    Hamann, Sophie Amalie
    Kallestrup, Per
    Hjortdal, Vibeke Elisabeth
    Tripathee, Ashish
    Neupane, Dinesh
    Patsche, Cecilie Blenstrup
    BMC PUBLIC HEALTH, 2020, 20 (01)
  • [23] Measurement of mid-upper arm circumference to screen for childhood malnutrition: General applicability and use in special populations
    Becker, Patricia
    Abdel-Rahman, Susan
    Nemet, Dan
    Marino, Luise V.
    Noritz, Garey
    Fisberg, Mauro
    Beretich, Kaitlan
    NUTRITION IN CLINICAL PRACTICE, 2024, 39 (06) : 1517 - 1528
  • [24] Large mid-upper arm circumference is associated with metabolic syndrome in middle-aged and elderly individuals: a community-based study
    Jie Shi
    Zhen Yang
    Yixin Niu
    Weiwei Zhang
    Xiaoyong Li
    Hongmei Zhang
    Ning Lin
    Hongxia Gu
    Jie Wen
    Guang Ning
    Li Qin
    Qing Su
    BMC Endocrine Disorders, 20
  • [25] Large mid-upper arm circumference is associated with metabolic syndrome in middle-aged and elderly individuals: a community-based study
    Shi, Jie
    Yang, Zhen
    Niu, Yixin
    Zhang, Weiwei
    Li, Xiaoyong
    Zhang, Hongmei
    Lin, Ning
    Gu, Hongxia
    Wen, Jie
    Ning, Guang
    Qin, Li
    Su, Qing
    BMC ENDOCRINE DISORDERS, 2020, 20 (01)
  • [26] Mid-upper arm circumference as an indicator of underweight in adults: a cross-sectional study from Nepal
    Lene Thorup
    Sophie Amalie Hamann
    Per Kallestrup
    Vibeke Elisabeth Hjortdal
    Ashish Tripathee
    Dinesh Neupane
    Cecilie Blenstrup Patsche
    BMC Public Health, 20
  • [27] Validating a linear regression equation using mid-upper arm circumference to predict body mass index
    Surendran, Adwaith Krishna
    Deepanjali, Surendran
    CLINICAL NUTRITION ESPEN, 2023, 57 : 613 - 616
  • [28] First Field Test of an Innovative, Wider Tape to Measure Mid-Upper Arm Circumference in Young Laotian Children
    Hess, Sonja Y.
    Hinnouho, Guy-Marino
    Barffour, Maxwell A.
    Bounheuang, Bangone
    Arnold, Charles D.
    Bell, David
    Marts, Tola H.
    Kounnavong, Sengchanh
    FOOD AND NUTRITION BULLETIN, 2018, 39 (01) : 28 - 38
  • [29] Association between mid-upper arm circumference and body mass index in pregnant women to assess their nutritional status
    Mishra, Kumar Guru
    Bhatia, Vikas
    Nayak, Ranjeeta
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (07) : 3321 - 3327
  • [30] Association between mid-upper arm circumference and cardiometabolic risk in Chinese population: a cross-sectional study
    Hou, Yanan
    Jia, Xu
    Xuan, Liping
    Zhu, Wen
    Deng, Chanjuan
    Wang, Long
    Zhao, Zhiyun
    Li, Mian
    Lu, Jieli
    Xu, Yu
    Chen, Yuhong
    Wang, Weiqing
    Bi, Yufang
    Xu, Min
    Wang, Tiange
    BMJ OPEN, 2019, 9 (09):