Reliability of Mid-Upper Arm Circumference Measurements taken by Community Health Nurses

被引:5
|
作者
Saeed, Hibbah Araba [1 ,3 ]
Mogendi, Joseph Birundu [2 ,5 ]
Akparibo, Robert [3 ]
Kolsteren, Patrick [2 ,4 ]
机构
[1] Noguchi Mem Inst Med Res, Accra, Ghana
[2] Univ Ghent, Fac Biosci Engn, B-9000 Ghent, Belgium
[3] Univ Sheffield, Sch Hlth & Related Res, Sheffield, S Yorkshire, England
[4] ITM, Antwerp, Belgium
[5] Mt Kenya Univ, Sch Hlth Sci, Dept Nutr & Dietet, Thika, Kenya
关键词
Mid-upper arm circumference; Reliability; Inter and intra observer variability; Community health nurses;
D O I
10.12944/CRNFSJ.3.1.04
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Mid upper arm circumference-based diagnosis of severe acute malnutrition is seen as very attractive because it is assumed to be simple to use in measuring the arm and also requires a single cut-off without having to compute an index or compare to a reference population. The circumference of the left upper arm measured at the mid-point between the tip of the shoulder and the tip of the elbow is referred to as mid upper arm circumference (MUAC). MUAC was originally used in emergency settings where huge populations had to be screened within a short time. However, in the past few years the development of community therapeutic care of acute malnutrition implied a need for a diagnostic tool. The general objective of the study was to assess the inter-and intra-observer variability in MUAC measurements of under-five children by community health nurses in selected communities of the Northern Region in Ghana. A community-based cohort study was conducted on a convenience sample of 120 community health nurses and nursing students from selected communities in the Northern region of Ghana. Each CHN measured MUAC for four unique children on three consecutive days to assess intra-observer variability. To assess inter-observer variability, 50 independent nursing students took MUAC measures of four children on the same day. Bland Altman plots showed a high degree of agreement of MUAC measures taken repeatedly for three days by the same observers and ICC = 0.993. MUAC measures among observers (inter-observer) and ICC = 0.042 showed a considerable level of variability among different observers. This study showed that MUAC is reliable when repeated measures are taken on children by the same observers, but using different observers for the same children showed a high level of variability.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 50 条
  • [1] Measuring muscle mass: Mid-arm muscle circumference or mid-upper arm circumference
    Duarte, Camila Kummel
    Silva, Luciana de Abreu
    Santos, Arimluz de Almeida
    CLINICAL NUTRITION, 2022, 41 (10) : 2424 - 2425
  • [2] The relationship between mid-upper arm circumference and blood pressure in Walter Sisulu University community
    Mthethwa, Wenzile S.
    Mampofu, Zuqaqambe M.
    Mokwena, Madigoahle A.
    Ramoshaba, Nthai E.
    BLOOD PRESSURE, 2024, 33 (01)
  • [3] Mid-upper arm circumference as a screening measure for identifying children with hypertension
    Ma, Chun-ming
    Li, Yang
    Gao, Guo-qin
    Yin, Fu-zai
    Wang, Rui
    Liu, Xiao-li
    Lu, Qiang
    BLOOD PRESSURE MONITORING, 2015, 20 (04) : 189 - 193
  • [4] Mid-upper arm circumference as a screening tool for identifying underweight adolescents
    Musa, Imad R.
    Omar, Saeed M.
    AlEed, Ashwaq
    Al-Nafeesah, Abdullah
    Adam, Ishag
    FRONTIERS IN NUTRITION, 2023, 10
  • [5] Mid-upper arm circumference as a screening tool for identifying adolescents with thinness
    Sisay, Binyam Girma
    Haile, Demewoz
    Hassen, Hamid Yimam
    Gebreyesus, Seifu Hagos
    PUBLIC HEALTH NUTRITION, 2021, 24 (03) : 457 - 466
  • [6] Mid-upper arm circumference measurement for severe malnutrition screening in underfives
    Adelia, Stephanie
    Susanto, Johannes Capistrano
    PAEDIATRICA INDONESIANA, 2020, 60 (01) : 42 - 52
  • [7] Developing Nomogram to Estimate Birth Weight from Head Circumference and Mid-Upper Arm Circumference
    Das, Shubhadeep
    Ghosh, Moumita
    Mitra, Souvik
    Chatterjee, Rita
    Bhattacharyya, Subhasish
    De, Arun Kumar
    Chakraborty, Swapna
    JOURNAL OF TROPICAL PEDIATRICS, 2012, 58 (04) : 307 - 310
  • [8] Mid-upper Arm Circumference as an Indicator of Quality of Life of Patients with Advanced Cancer
    Won, Seon-Hye
    Hiratsuka, Yusuke
    Suh, Sang-Yeon
    Bae, Hayoung
    Choi, Sung-Eun
    Kim, Yu Jung
    Kang, Beodeul
    Lee, Si Won
    Suh, Koung Jin
    Kim, Ji-Won
    Kim, Se Hyun
    Kim, Jin Won
    Lee, Keun-Wook
    JOURNAL OF PALLIATIVE CARE, 2023, 38 (01) : 24 - 29
  • [9] Mid-upper arm circumference predicts the risk of gestational diabetes in early pregnancy
    Ma, Ning
    Bai, Liwei
    Niu, Ziru
    Lu, Qiang
    BMC PREGNANCY AND CHILDBIRTH, 2024, 24 (01)
  • [10] Mid-upper arm circumference (MUAC) as a feasible tool in detecting adult malnutrition
    Van Tonder, E.
    Mace, L.
    Steenkamp, L.
    Tydeman-Edwards, R.
    Gerber, K.
    Friskin, D.
    SOUTH AFRICAN JOURNAL OF CLINICAL NUTRITION, 2019, 32 (04) : 93 - 98