MAGNETIC-RESONANCE FOR THE ANESTHETIST .2. ANESTHESIA AND MONITORING IN MR UNITS

被引:38
|
作者
PEDEN, CJ
MENON, DK
HALL, AS
SARGENTONI, J
WHITWAM, JG
机构
[1] HAMMERSMITH HOSP,NMR UNIT,LONDON W12 0HS,ENGLAND
[2] HAMMERSMITH HOSP,ANAESTHESIA,LONDON W12 0HS,ENGLAND
关键词
MEASUREMENT TECHNIQUES; NUCLEAR MAGNETIC RESONANCE; ANESTHESIA; MAGNETIC RESONANCE IMAGING; MONITORING; BLOOD PRESSURE; CARBON DIOXIDE; ELECTROCARDIOGRAPHY; OXYGEN; EQUIPMENT; ANESTHESIA MACHINES;
D O I
10.1111/j.1365-2044.1992.tb02278.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Anaesthetists are increasingly involved in patient care during magnetic resonance imaging and spectroscopy. This paper describes a system which has been developed for the management of critically ill patients and the conduct of anaesthesia in a magnetic resonance unit with a 1.6 tesla whole body magnet. Difficulties which arise from working in a confined space in a high magnetic field are highlighted. Different approaches to anaesthesia, sedation and the modification of equipment for use in this environment are reviewed. The problems associated with patient monitoring within a magnetic field are discussed and some solutions are suggested. A transport system for critically ill patients is described and a protocol for management is outlined. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:508 / 517
页数:10
相关论文
共 39 条
  • [1] MAGNETIC-RESONANCE FOR THE ANESTHETIST .1. PHYSICAL PRINCIPLES, APPLICATIONS, SAFETY ASPECTS
    MENON, DK
    PEDEN, CJ
    HALL, AS
    SARGENTONI, J
    WHITWAM, JG
    ANAESTHESIA, 1992, 47 (03) : 240 - 255
  • [2] CIRCULATORY MONITORING OF CHILDREN DURING ANESTHESIA IN LOW-FIELD MAGNETIC-RESONANCE-IMAGING
    SELLDEN, H
    DECHATEAU, P
    EKMAN, G
    LINDER, B
    SAAF, J
    WAHLUND, LO
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (01) : 41 - 43
  • [3] MAGNETIC-RESONANCE ANGIOGRAPHY MONITORING OF STREPTOKINASE IN OCCLUSION OF THE MIDDLE CEREBRAL-ARTERY
    FEDERICO, F
    DAPRILE, P
    LAMBERTI, P
    ABBINANTE, A
    DAMIANI, M
    CARELLA, A
    ITALIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1993, 14 (09): : 629 - 632
  • [4] DETECTION OF DEGRADATION OF MAGNETIC-RESONANCE (MR) IMAGES - COMPARISON OF AN AUTOMATED MR IMAGE-QUALITY ANALYSIS SYSTEM WITH TRAINED HUMAN OBSERVERS
    GARDNER, EA
    ELLIS, JH
    HYDE, RJ
    AISEN, AM
    QUINT, DJ
    CARSON, PL
    ACADEMIC RADIOLOGY, 1995, 2 (04) : 277 - 281
  • [5] MAGNETIC-RESONANCE DEMONSTRATION OF VERTEBRAL ARTERY DISSECTION - REPORT OF 2 CASES
    QUINT, DJ
    SPICKLER, EM
    JOURNAL OF NEUROSURGERY, 1990, 72 (06) : 964 - 967
  • [6] AGE-RELATED-CHANGES OF WATER AND FAT-CONTENT IN MUSCLES ESTIMATED BY MAGNETIC-RESONANCE (MR) IMAGING
    TSUBAHARA, A
    CHINO, N
    AKABOSHI, K
    OKAJIMA, Y
    TAKAHASHI, H
    DISABILITY AND REHABILITATION, 1995, 17 (06) : 298 - 304
  • [7] Magnetic resonance imaging of frozen tissues: Temperature-dependent MR signal characteristics and relevance for MR monitoring of cryosurgery
    Daniel, BL
    Butts, K
    Block, WF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (03) : 627 - 630
  • [8] AGE-RELATED MODIFICATION IN THE THYMUS OF RATS AND MICE - AN INVIVO STUDY BY MAGNETIC-RESONANCE - MR IMAGING OF THE THYMUS
    SBARBATI, A
    BALERCIA, G
    BALDASSARRI, A
    LECLERCQ, F
    ANTONAKIS, K
    BOICELLI, A
    OSCULATI, F
    THYMUS, 1991, 17 (03) : 199 - 203
  • [9] EVALUATION OF MYELINATION BY MEANS OF THE T-2 VALUE ON MAGNETIC-RESONANCE IMAGINE
    ONO, J
    KODAKA, R
    IMAI, K
    ITAGAKI, Y
    TANAKA, J
    INUI, K
    NAGAI, T
    SAKURAI, K
    HARADA, K
    OKADA, S
    BRAIN & DEVELOPMENT, 1993, 15 (06) : 433 - 438
  • [10] EXTRAVASCULAR TOXICITY OF 2 MAGNETIC-RESONANCE CONTRAST AGENTS - PRELIMINARY EXPERIENCE IN THE RAT
    COHAN, RH
    LEDER, RA
    HERZBERG, AJ
    HEDLUND, LW
    WHEELER, CT
    BEAM, CA
    NADEL, SN
    DUNNICK, NR
    INVESTIGATIVE RADIOLOGY, 1991, 26 (03) : 224 - 226