Aperture effect for LINAC-based SRS in small target treatment

被引:0
|
作者
Li, Kaile [1 ,2 ]
机构
[1] John R Marsh Canc Ctr, Med Campus Rd,Suite 129, Hagerstown, MD 21742 USA
[2] Associates Med Phys, Lanham, MD 20706 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2016年 / 4卷 / 01期
关键词
stereotactic radiosurgery; small target; LINAC; MLC; cone; beam aperture;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Stereotactic Radiosurgery (SRS) can utilize different techniques. For small target SRS, the selections of the apertures of cone or MLC field influence the treatment significantly. In this study, while the aperture of the MLC and cone field vary, the dosimetric characteristics of the two techniques are compared for SRS of small targets which are in the favor of magnifying the dosimetric effect. Methods and Materials: An anthropomorphic phantom was used to simulate the patient with an arbitrary drawn cranial target, whose volume is equivalent to a 4 millimeter sphere. Single 360 ARC plans were generated with Eclipse external beam and cone based treatment planning system from Varian Medical System. For MLC based plan, the apertures fit to the structure with circle margins varying with 2mm, 3mm, 4mm, 5mm and 6mm. These setups were compared with the cones being selected to be 5mm, 10mm, 12mm, 14mm and 16mm in diameter. For the MLC based plan, the leaf-edge-contour meet points were selected to be in the middle. Jaw positions were used both recommend and optimize options, which are provided by the treatment planning system. Mean dose was treated as the prescription dose. Comparison of the two planning techniques was carried out using 12Gy Volume (V12Gy) from dose-volume histogram (DVH), maximum dose to the prescription dose ratio (MDPD), ratio PITV (PIV/TV), radiation conformity index (RCI), which is defined to be TVPIV/PIV, and an integrated conformity index (TVPIV2/(TVxPIV)), where PIV is the prescription isodose surface volume, TV is target volume, and TV PIV is the intersection of TV and the PIV. Results: For the apertures used for this study, while MLC and cone based plans were compared by prescribed at 20Gy, the V12Gy ranges were from 1.0cc to 5.3cc with average at 3.3cc, and 0.1cc to 3.2cc with average value at 1.5cc. The variations of MDPD were 9% with average value at 1.04, and 12% with average at 1.03. The varying ranges of PITV were 35% with average value at 0.80, and 17% with average value at 0.54. Integrated conformity index (ICI) variations were up to 45% with average value at 0.34, and at the level of the 7% with average value at 0.42. Conclusions: For small target SRS, there are larger variations in V12Gy, PITV, and ICI in MLC based plan than those of cone based plan, while the difference is not significant for MDPD in both settings at the selected aperture sizes. These information could help in decision making through sensitivity study while sufficient clinical outcome information were available. The multiple ARC treatment plan and the clinical reality of algorithm for small aperture also need further investigation.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 50 条
  • [21] End-To-End Testing of Linac-Based SRS Using Radiochromic Film & CIRS STEEV Phantom
    Ambrose, R.
    Presser, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E326 - E326
  • [22] Linac-based stereotatic radiotherapy for brain metastases: A palliative treatment?
    Rosier, J. -F.
    Dessy, F.
    Gilbeau, L.
    Doneux, A.
    Mitine, C.
    Harzee, L.
    Hoornaert, M. Th.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S487 - S487
  • [23] LINAC-BASED SMALL-FIELD RADIOTHERAPY FOR BRAIN-TUMORS
    TOKUUYE, K
    AKINE, Y
    TOKITA, N
    SATOH, M
    CHUREI, H
    TSUKIYAMA, I
    EGAWA, S
    OYAMA, H
    NAGANE, M
    SHIBUI, S
    NOMURA, K
    IIO, M
    HARA, T
    RADIOTHERAPY AND ONCOLOGY, 1993, 27 (01) : 55 - 58
  • [24] Characterizing Isocenter Reproducibility for Linac-Based Stereotactic Treatment Accuracy
    Pinkham, D.
    Hancock, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E598 - E598
  • [25] Linac-based radiosurgery in the treatment of trigeminal neuralgia: a preliminary report
    Tome, W
    Bradley, K
    Hong, T
    Hayes, L
    Peng, L
    Resnick, D
    Mehta, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S117 - S117
  • [26] Commissioning of Mobius3D for Linac-Based SRS and Determination of the Dosimetric-Leaf-Gap
    McCarroll, R.
    Sabouri, P.
    Lamichhane, N.
    Poirier, Y.
    Yi, B.
    Chen, S.
    Guerrero, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E612 - E612
  • [27] Dosimetric study of LINAC-based SRS/SRT of multiple brain lesions:multiple/single isocenter approach
    Winkel, D.
    Eppinga, W. S. C.
    Intven, M. P. W.
    Werensteijn-Honingh, A. M.
    Hes, J.
    Snoeren, L. M. W.
    Bol, G. H.
    Raaymakers, B. W.
    Jurgenliemk-Schulz, I. M.
    Kroon, P. S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1041 - S1042
  • [28] Intrafraction error analysis of homemade mouth-bite masks in linac-based SRS for brain metastasis
    Pisoni, V.
    Trivellato, S.
    Corbetta, S.
    Masperi, A.
    Ierman, E.
    Bianchi, S. P.
    Lucchini, R.
    Panizza, D.
    Arcangeli, S.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S784 - S786
  • [29] Correlation between HI, GI, CI and Size of Metastases for Linac-Based High Dose SRT / SRS
    Tas, B.
    Durmus, I. F.
    Okumus, A.
    Uzel, O. E.
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 : 39 - 39
  • [30] Factors That Contribute to Intra-Fractional Motion during Single-Isocenter Linac-Based SRS
    Goia, D. R.
    Mccaw, T. J.
    Choi, S.
    Mccall, N. S.
    Abdullah, K. G.
    Huq, M. S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7901 - 7901