Validation of post mortem dental CT for disaster victim identification

被引:23
作者
Ruder, Thomas D. [1 ,2 ,3 ]
Thali, Yannick A. [1 ]
Rashid, Saiful N. A. [4 ,5 ]
Munda, Michael T. [1 ,6 ]
Thali, Michael J. [1 ]
Hatch, Gary M. [7 ,8 ]
Christensen, Angi M. [9 ]
Somaini, Sandra [10 ]
Ampanozi, Garyfalia [1 ,3 ]
机构
[1] Univ Zurich, Dept Forens Med & Imaging, Inst Forens Med, Winterthurerstr 190-52, CH-8057 Zurich, Switzerland
[2] Univ Hosp Bern, Inst Diagnost Intervent & Pediat Radiol, CH-3010 Bern, Switzerland
[3] Univ Bern, Inst Forens Med, Ctr Forens Imaging & Virtopsy, CH-3012 Bern, Switzerland
[4] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Imaging, Serdang 43400, Malaysia
[5] Hosp Kuala Lumpur, Natl Inst Forens Med, Kuala Lumpur, Malaysia
[6] JDMT Med Serv AG, CH-8330 Pfaffikon, Switzerland
[7] Univ New Mexico, Sch Med, Radiol Pathol Ctr Forens Imaging, Dept Radiol, Albuquerque, NM 87102 USA
[8] Univ New Mexico, Sch Med, Radiol Pathol Ctr Forens Imaging, Dept Pathol, Albuquerque, NM 87102 USA
[9] Fed Bur Invest Lab, Quantico, VA 22135 USA
[10] Univ Hosp Bern, Inst Diagnost & Intervent Neuroradiol, CH-3010 Bern, Switzerland
关键词
Forensic radiology; Forensic identification; Dental identification; Post mortem CT; Post mortem dental-CT;
D O I
10.1016/j.jofri.2016.01.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to test the accuracy and inter-reader variability of comparative radiologic identification based on dental post mortem computed tomography (PMCT) and ante mortem (AM) dental radiographs. Five raters with varying degrees of expertize and experience independently compared 115 dental PMCT images to 114 AM dental radiographs to identify matching pairs (n = 98), unmatched PMCT images (n = 17), and unmatched AM radiographs (n = 16). Levels of confidence (LOC) and number of concordant features (NOCF) of matched pairs were documented. Accuracy of matches/exclusions, interrater correlation coefficient and correlation between correct matches/exclusions, LOC and NOCF were calculated for all raters. Mean accuracy was 92% for matches and 80% for exclusions. Interrater correlation coefficient regarding LOC and NOCF were 0.623 and 0.907 respectively. LOC were correlated with NOCF of matched pairs but accuracy of matches/exclusions was neither correlated to LOC nor to NOCF. This study shows that visual comparison of PMCT images with AM dental radiographs is a reliable method for identification. Accuracy of identification using PMCT/AM dental radiographs was as high as in comparable studies using post mortem (PM) dental radiographs/AM dental radiographs. Raters with practical experience in forensic identification and experience with the imaging modality (in this case: dental PMCT) achieved higher accuracy than inexperienced raters. Match accuracy did not correlate with subjective confidence or number of concordant features. It is advised to work in teams rather than individually when dealing with real cases in forensic identification, to minimize subjective interpretation and avoid confirmation bias. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 29 条
  • [1] Acharya A B, 2003, J Forensic Odontostomatol, V21, P6
  • [2] American Board of Forensic Odontology, DIPL REF MAN
  • [3] The rise of forensic and post-mortem radiology-Analysis of the literature between the year 2000 and 2011
    Baglivo, Manuela
    Winklhofer, Sebastian
    Hatch, Gary M.
    Ampanozi, Garyfalia
    Thali, Michael J.
    Ruder, Thomas D.
    [J]. JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2013, 1 (01) : 3 - 9
  • [4] A current perspective on forensic radiology
    Christensen, Angi M.
    Hatch, Gary M.
    Brogdon, B. G.
    [J]. JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2014, 2 (03) : 111 - 113
  • [5] Dror I.E., 2006, J FORENSIC IDENTIF, P56600
  • [6] Subjectivity and bias in forensic DNA mixture interpretation
    Dror, Itiel E.
    Hampikian, Greg
    [J]. SCIENCE & JUSTICE, 2011, 51 (04) : 204 - 208
  • [7] Feasibility and validation of virtual autopsy for dental identification using the Interpol dental codes
    Franco, Ademir
    Thevissen, Patrick
    Coudyzer, Walter
    Develter, Wim
    Van de Voorde, Wim
    Oyen, Raymond
    Vandermeulen, Dirk
    Jacobs, Reinhilde
    Willems, Guy
    [J]. JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2013, 20 (04) : 248 - 254
  • [8] RADid: A pictorial review of radiologic identification using postmortem CT
    Hatch, Gary M.
    Dedouit, Fabrice
    Christensen, Angi M.
    Thali, Michael J.
    Ruder, Thomas D.
    [J]. JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2014, 2 (02) : 52 - 59
  • [9] Interpol, DIS VICT ID GUID DVI
  • [10] Ultra-high-resolution dual-source CT for forensic dental visualization - discrimination of ceramic and composite fillings
    Jackowski, C.
    Wyss, M.
    Persson, A.
    Classens, M.
    Thali, M. J.
    Lussi, A.
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2008, 122 (04) : 301 - 307