IODIXANOL IN ABDOMINAL DIGITAL SUBTRACTION ANGIOGRAPHY - A RANDOMIZED, DOUBLE-BLIND, PARALLEL TRIAL WITH IODIXANOL AND IOHEXOL

被引:0
|
作者
SINGH, K
SUNDGREN, R
BOLSTAD, B
BJORK, L
LIE, M
机构
[1] NYCOMED IMAGING A-S,CLIN RES & DEV,OSLO,NORWAY
[2] UNIV TROMSO HOSP,DEPT RADIOL,N-9012 TROMSO,NORWAY
[3] UNIV TROMSO HOSP,DEPT SURG,N-9012 TROMSO,NORWAY
关键词
CONTRAST MEDIA; COMPARATIVE STUDIES; IODIXANOL; IOHEXOL; ANGIOGRAPHY;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The safety, tolerability and efficacy of iodixanol 270 mg I/ml were compared to those of iohexol 300 mg I/ml in a double-blind, randomized, parallel abdominal intra-arterial DSA phase III trial. Fifty-nine patients were included in the trial; 39 patients received iodixanol and 20 received iohexol. The mean volume of iodixanol administered was 235.8 ml (0.93 g I/kg b.w.) while the mean volume of iohexol was 254.7 ml (1.10 g I/kg b.w.). No differences in diagnostic information and radiographic density were apparent in spite of the difference in the concentration of iodine. No serious adverse events occurred. Four patients (10%) in the iodixanol group and 2 (10%) in the iohexol group experienced adverse events. Eight percent of the injections of iodixanol promoted discomfort, compared to 12% of the injections of iohexol. An increase in S-urea and S-creatinine was seen with both agents the first day after injection, but appeared to be less pronounced with iodixanol than with iohexol. Other serum tests revealed no changes of clinical importance. Both iodixanol and iohexol were found to be effective, safe and well tolerated contrast media for abdominal intra-arterial DSA.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 42 条
  • [1] Iodixanol in cerebral computed tomography: a randomized, double-blind, phase III, parallel study with iodixanol an iohexol
    Doerfler, A
    Fiebach, J
    Wanke, I
    Forsting, M
    Henseke, P
    Sartor, K
    EUROPEAN RADIOLOGY, 1999, 9 (07) : 1362 - 1365
  • [2] DOUBLE-BLIND, RANDOMIZED COMPARISON OF IODIXANOL-320 AND IOHEXOL-300 FOR CEREBRAL-ANGIOGRAPHY
    POIRIER, VC
    MONSEIN, LH
    NEWBERRY, PD
    KREPS, BJ
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S43 - S44
  • [3] IODIXANOL IN INTRAARTERIAL CEREBRAL DIGITAL SUBTRACTION ANGIOGRAPHY - A COMPARISON WITH IOHEXOL
    KENDALL, BE
    SHEPPICK, A
    NOSSEN, JO
    STEVENS, JM
    NEURORADIOLOGY, 1995, 37 (07) : 512 - 514
  • [4] IODIXANOL IN FEMORAL ARTERIOGRAPHY - A RANDOMIZED, DOUBLE-BLIND, PHASE-III, PARALLEL STUDY WITH IODIXANOL 270-MG I/ML AND IOHEXOL 300-MG I/ML
    THORSTENSEN, O
    ALBRECHTSSON, U
    CALISSENDORFF, B
    LARUSDOTTIR, H
    NORGREN, L
    TENGVAR, M
    BOLSTAD, B
    ACTA RADIOLOGICA, 1994, 35 (06) : 629 - 631
  • [5] Clinical experience with iobitridol 250-300 in digital subtraction angiography - Double-blind randomized studies vs iopromide and iohexol
    Bouard, JC
    Lyonnet, D
    Illes, JP
    BouardMonnier, C
    Rouviere, O
    Pangaud, C
    ACTA RADIOLOGICA, 1996, 37 : 85 - 88
  • [6] IODIXANOL IN CARDIOANGIOGRAPHY - A DOUBLE-BLIND PARALLEL COMPARISON BETWEEN IODIXANOL 320-MG I/ML AND IOXAGLATE 320-MG I/ML
    TVEIT, K
    BOLZ, KD
    BOLSTAD, B
    HAUGLAND, T
    BERG, KJ
    SKJAERPE, T
    KLOSTER, YF
    ACTA RADIOLOGICA, 1994, 35 (06) : 614 - 618
  • [7] A Case of Severe Lethal Allergic Reaction Caused by Iodixanol After Digital Subtraction Angiography
    Xie, Yu
    Xiong, Xuan
    Li, Bujun
    Hu, Kai
    Yin, Caixia
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (05) : e461 - e463
  • [8] Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT
    Zo'o, Martin
    Hoermann, Marcus
    Balassy, Csilla
    Brunelle, Francis
    Azoulay, Robin
    Pariente, Daniele
    Panuel, Michel
    Le Dosseur, Patrick
    PEDIATRIC RADIOLOGY, 2011, 41 (11) : 1393 - 1400
  • [9] DOUBLE-BLIND COMPARISON OF SAFETY AND EFFICACY OF IOMEPROL AND IOPAMIDOL IN CAROTID DIGITAL SUBTRACTION ANGIOGRAPHY
    BELTRAMELLO, A
    PIOVAN, E
    ROSTA, L
    EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 : S67 - S72
  • [10] Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial
    Park, Eun-Ah
    Lee, Whal
    Kang, Doo Kyoung
    Kim, Sung Jin
    Kim, Young-Ju
    Kim, Yookyung
    Sung, Yon Mi
    Song, Soon-Young
    Oh, Yu-Whan
    Yong, Hwan Seok
    Lee, Heon
    Jeon, Eui-Yong
    Jin, Gong-Yong
    Choi, Byoung Wook
    Choi, Sang-Il
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (03) : 330 - 338