The effect of pneumoperitoneum and Trendelenburg position on respiratory mechanics during pelviscopic surgery

被引:45
|
作者
Suh, Min Kyo [1 ]
Seong, Kyu Wan [1 ]
Jung, Sung Hwan [1 ]
Kim, Seong Su [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Anesthesiol & Pain Med, 415 Bangdong Ri,Sacheon Myeon, Kangnung 210711, South Korea
关键词
Airway pressure; Head-down tilt; Lung compliance; Pelviscopy; Pneumoperitoneum;
D O I
10.4097/kjae.2010.59.5.329
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Conventional pelviscopic surgery requires pneumoperitoneum with CO2 gas insufflation and lithotomy-Trendelenburg position. Pneumoperitoneum and Trendelenburg position may influence intraoperative respiratory mechanics in anesthetic management. This study was conducted to investigate the influence of pneumoperitoneum and Trendelenburg position on respiratory compliance and ventilation pressure. Methods: Twenty-five patients scheduled for elective gynecologic laparoscopy were evaluated. The patients had no preexisting lung or heart disease or pathologic lung function. Conventional general anesthesia with thiopental sodium, lidocaine, rocuronium, and sevoflurane was administered. The peak inspiratory pressure, plateau pressure, and end-tidal CO2 were measured before and after creation of pneumoperitoneum with an intraabdominal pressure of 12 mmHg, then after 10 minutes and 30 minutes in the 20 degrees Trendelenburg position, and after deflation of pneumoperitoneum. The dynamic lung compliance was then calculated. Results: Following creation of pneumoperitoneum, there was a significant increase in peak inspiratory pressure (6 cmH(2)O), plateau pressure (7 cmH(2)O), and end-tidal CO2 (5 mmHg), while dynamic lung compliance decreased by 12 ml/cmH(2)O. Overall, the Trendelenburg position induced no significant hemodynamic or pulmonary changes. Conclusions: The effects of pneumoperitoneum significantly reduced dynamic lung compliance and increased peak inspiratory and plateau pressures. The Tredelenburg position did not change these parameters.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 50 条
  • [41] Lung mechanics during video-assisted abdominal surgery in Trendelenburg position: a cross-sectional propensity-matched comparison between classic laparoscopy and robotic-assisted surgery
    Popescu, Mihai
    Olita, Mihaela Roxana
    Stefan, Mara Oana
    Mihaila, Mariana
    Sima, Romina-Marina
    Tomescu, Dana
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [42] Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients
    Wirth, Steffen
    Biesemann, Andreas
    Spaeth, Johannes
    Schumann, Stefan
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (02): : 753 - 760
  • [43] Effects of pneumoperitoneal pressure and position changes on respiratory mechanics during laparoscopic colectomy
    Park, Jin Suk
    Ahn, Eun Jin
    Ko, Duk Dong
    Kang, Hyun
    Shin, Hwa Yong
    Baek, Chong Hwa
    Jung, Yong Hun
    Woo, Young Cheol
    Kim, Jin Yun
    Koo, Gill Hoi
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (05) : 419 - 424
  • [44] Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients
    Steffen Wirth
    Andreas Biesemann
    Johannes Spaeth
    Stefan Schumann
    Surgical Endoscopy, 2017, 31 : 753 - 760
  • [45] Effects of pneumoperitoneum and reverse Trendelenburg position on cardiopulmonary function in morbidly obese patients receiving laparoscopic gastric banding
    Casati, A
    Comotti, L
    Tommasino, C
    Leggieri, C
    Bignami, E
    Tarantino, F
    Torri, G
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (05) : 300 - 305
  • [46] Arterial to end-tidal carbon dioxide pressure gradient increases with age in the steep Trendelenburg position with pneumoperitoneum
    Choi, Dae-Kee
    Lee, In-Gyu
    Hwang, Jai-Hyun
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (03) : 209 - 215
  • [47] Effects of two different ventilation strategies on respiratory mechanics during robotic-gynecological surgery
    Spinazzola, Giorgia
    Ferrone, Giuliano
    Cipriani, Flora
    Caputo, Cosimo Tommaso
    Rossi, Marco
    Conti, Giorgio
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2019, 259 : 122 - 128
  • [48] Effect of the "Recruitment" Maneuver on Respiratory Mechanics in Laparoscopic Sleeve Gastrectomy Surgery
    Sumer, Ismail
    Topuz, Ufuk
    Alver, Selcuk
    Umutoglu, Tarik
    Bakan, Mefkur
    Zengin, Seniyye Ulgen
    Coskun, Halil
    Salihoglu, Ziya
    OBESITY SURGERY, 2020, 30 (07) : 2684 - 2692
  • [49] Cardiac function during steep Trendelenburg position and CO2 pneumoperitoneum for robotic-assisted prostatectomy:: a trans-oesophageal Doppler probe study
    Falabella, Andres
    Moore-Jeffries, Earl
    Sullivan, Michael J.
    Nelson, Rebecca
    Lew, Michael
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2007, 3 (04) : 312 - 315
  • [50] Effect of analgesia nociception index monitor-based nociception control on perioperative stress responses during laparoscopic surgery in Trendelenburg position: a randomized controlled trial
    Kim, Seung Hyun
    Chang, Chul Ho
    Lee, Jeong-Rim
    Seo, Seok Kyo
    Kwon, Young In
    Lee, Jae Hoon
    FRONTIERS IN MEDICINE, 2023, 10