COMPARISON OF AUTOMATIC QT MEASUREMENT TECHNIQUES IN THE NORMAL 12-LEAD ELECTROCARDIOGRAM

被引:1
作者
MCLAUGHLIN, NB [1 ]
CAMPBELL, RWF [1 ]
MURRAY, A [1 ]
机构
[1] FREEMAN RD HOSP,ACAD CARDIOL UNIT,NEWCASTLE TYNE,TYNE & WEAR,ENGLAND
来源
BRITISH HEART JOURNAL | 1995年 / 74卷 / 01期
关键词
QT INTERVAL; ELECTROCARDIOGRAPHY; AUTOMATIC QT MEASUREMENT TECHNIQUES;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To undertake a quantitative assessment of different automatic QT measurement techniques and investigate the influence of electrocardiogram filtering and algorithm parameters. Design-Four methods for identifying the end of the T wave were compared: (1) threshold crossing of the T wave (TH); (2) threshold crossing of the differential of the T wave (DTH); (3) intercept of an isoelectric level and the maximum T wave slope (SI); and (4) intercept of an isoelectric level and the line passing through the peak and the point of maximum slope of the T wave (PSI). Automatic QT measurements were made by all techniques following different electrocardiogram filtering and, when appropriate, with four different isoelectric levels and with three different threshold levels. Subjects-12 simultaneous standard electrocardiogram leads, containing at least two electrocardiogram complexes, were recorded from 25 healthy volunteers relaxing in a semirecumbent position. Main outcome measure-Mean and standard deviation of differences between reference and automatic QT measurements were compared for the four techniques. Results-The mean automatic QT measurements varied by up to 62 ms, which was greater than has been found between manual measurements by experienced clinicians. Technique TH was particularly poor. The other techniques produced consistent results for most electrocardiogram filter, isoelectric level, and threshold level settings; but technique SI underestimated QT relative to the other techniques. Conclusion-Different QT measurement techniques produced results which were influenced, to varying degrees, by filtering and technique variables. This is relevant for the inter-comparison of studies using different techniques. Technique TH, a common approach, is not recommended.
引用
收藏
页码:84 / 89
页数:6
相关论文
共 14 条
[1]   ERRORS IN THE VISUAL DETERMINATION OF CORRECTED QT (QTC) INTERVAL DURING ACUTE MYOCARDIAL-INFARCTION [J].
AHNVE, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (03) :699-702
[2]  
Algra A., 1987, Computers in Cardiology (Cat. No.CH2476-0), P117
[3]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[4]   IMPORTANCE OF LEAD SELECTION IN QT INTERVAL MEASUREMENT [J].
COWAN, JC ;
YUSOFF, K ;
MOORE, M ;
AMOS, PA ;
GOLD, AE ;
BOURKE, JP ;
TANSUPHASWADIKUL, S ;
CAMPBELL, RWF .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (01) :83-87
[5]  
DAY CP, 1990, BRIT HEART J, V63, P342
[6]   AMBULATORY SUDDEN CARDIAC DEATH - MECHANISMS OF PRODUCTION OF FATAL ARRHYTHMIA ON THE BASIS OF DATA FROM 157 CASES [J].
DELUNA, AB ;
COUMEL, P ;
LECLERCQ, JF .
AMERICAN HEART JOURNAL, 1989, 117 (01) :151-159
[7]   PRECORDIAL QT INTERVAL DISPERSION AS A MARKER OF TORSADE-DE-POINTES - DISPARATE EFFECTS OF CLASS IA ANTIARRHYTHMIC DRUGS AND AMIODARONE [J].
HII, JTY ;
WYSE, DG ;
GILLIS, AM ;
DUFF, HJ ;
SOLYLO, MA ;
MITCHELL, B .
CIRCULATION, 1992, 86 (05) :1376-1382
[8]   NEW ALGORITHM FOR QT INTERVAL-ANALYSIS IN 24-HOUR HOLTER ECG - PERFORMANCE AND APPLICATIONS [J].
LAGUNA, P ;
THAKOR, NV ;
CAMINAL, P ;
JANE, R ;
YOON, HR .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) :67-73
[9]   ELECTROCARDIOGRAPHIC QUANTITATION OF VENTRICULAR REPOLARIZATION [J].
MERRI, M ;
BENHORIN, J ;
ALBERTI, M ;
LOCATI, E ;
MOSS, AJ .
CIRCULATION, 1989, 80 (05) :1301-1308
[10]   SPATIAL VARIATION OF QT INTERVALS IN NORMAL PERSONS AND PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION [J].
MIRVIS, DM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (03) :625-631