Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type

被引:95
作者
Alikhasi, Marzieh [1 ]
Siadat, Hakime [1 ]
Nasirpour, Alireza [2 ]
Hasanzade, Mahya [3 ]
机构
[1] Univ Tehran Med Sci, Dept Prosthodont, Dent Res Inst, Dent Res Ctr, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Dent, Dent Student Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Dent, Dept Prosthodont, Dent Res Ctr,Dent Res Inst, Tehran, Iran
关键词
D O I
10.1155/2018/3761750
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose. The aim of this in vitro study was to compare the accuracy of different implant impression techniques of the maxillary full arch with tilted implants of two connection types. Materials and Methods. Two maxillary edentulous acrylic resin models with two different implant connections (internal or external) served as a reference model. Each model had two anterior straight and two posterior angulated implants. Ninety impressions were made using an intraoral scanner (Trios 3Shape) with scan bodies for digital impression (groups DII and DIE), a custom open tray with additional silicone for the conventional direct group (groups CDI and CDE), and a custom closed tray with additional silicone for the conventional indirect group (groups CII and CIE) from both internal and external models, respectively. A coordinate-measuring machine (CMM) was used to measure linear and angular displacement for conventional specimens. For digital groups, an optical CMM was used to scan the reference model. STL data sets from the digital specimen were superimposed on STL reference data sets to assess angular and linear deviations. Data were analyzed with three-way ANOVA and t-test at a. 0.05. Results. (ere were significant angular and linear distortion differences among three impression groups (P < 0.001), angular distortion differences between internal and external connections (P < 0.001), and between straight and tilted implants for either linear (P < 0.001) or angular (P = 0.002) distortion. The type of the connection and implant angle did not have any effect on linear and angular distortion of the digital technique (p > 0.05). Minimum angular and linear distortion was seen for tilted implants in DII and DIE groups (0.36 degrees +/- 0.37 and 0.16 +/- 0.1 mm). Conclusion. Impression techniques (digital versus conventional) affected the transfer accuracy. Digital techniques demonstrated superior outcome in comparison with conventional methods, and the direct technique was better than the indirect conventional technique. Connection type and implant angulation were other factors that influenced accuracy. However, when digital impression was applied, accuracy was not affected by the type of connection and angulation.
引用
收藏
页数:9
相关论文
共 36 条
[1]   Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners [J].
Abdel-Azim, Tamer ;
Rogers, Kelly ;
Elathamna, Eiad ;
Zandinejad, Amirali ;
Metz, Michael ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) :554-559
[2]  
Al Quran FA, 2012, QUINTESSENCE INT, V43, P119
[3]   AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS [J].
Al-Abdullah, Khaled ;
Zandparsa, Roya ;
Finkelman, Matthew ;
Hirayama, Hiroshi .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02) :90-100
[4]  
Al-Turki L. E. E., 2002, INT J PROSTHODONTICS, V15
[5]   The Effect of Implant Angulation on the Transfer Accuracy of External-Connection Implants [J].
Alikhasi, Marzieh ;
Siadat, Hakimeh ;
Rahimian, Susan .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) :822-829
[6]   Digital vs. conventional full-arch implant impressions: a comparative study [J].
Amin, Sarah ;
Weber, Hans Peter ;
Finkelman, Matthew ;
El Rafie, Khaled ;
Kudara, Yukio ;
Papaspyridakos, Panos .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) :1360-1367
[7]   Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study [J].
Andriessen, Frank S. ;
Riikens, David R. ;
van der Meer, Wither J. ;
Wismeijer, Daniell W. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) :186-194
[8]   Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis [J].
Basaki, Kinga ;
Alkumru, Hasan ;
De Souza, Grace ;
Finer, Yoav .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) :792-799
[9]  
Beyabanaki E., 2015, J PROSTHODONT, V26, P48
[10]   Laser digitization of casts to determine the effect of tray selection and cast formation technique on accuracy [J].
Brosky, ME ;
Pesun, IJ ;
Lowder, PD ;
DeLong, R ;
Hodges, JS .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02) :204-209