NONSTATIONARITY BROADENING IN PULSED DOPPLER SPECTRUM MEASUREMENTS

被引:53
|
作者
FISH, PJ
机构
[1] School of Electronic Engineering Science, University of Wales-Bangor, Bangor, Gwynedd Wales LL57 1UT, Dean Street
关键词
DOPPLER ULTRASOUND; ULTRASONIC DOPPLER SHIFT SPECTRUM ANALYSIS; SPECTRUM; SPECTRAL ESTIMATION; DOPPLER POWER SPECTRUM; FAST-FOURIER TRANSFORM (FFT); BLOOD FLOW; SIGNAL PROCESSING; STATIONARY; NONSTATIONARY; CYCLO-STATIONARY; WINDOWS; STATIONARY PHASE;
D O I
10.1016/0301-5629(91)90122-D
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional measurement of the spectrum of arterial signals from the pulsed ultrasonic Doppler instrument uses windowed, sequential data segments. The Doppler signal is assumed stationary for the duration of each segment. It is shown here that this assumption is often unreasonable and the effect of mean frequency variation during the data segment has been investigated for different windows and rates of change of mean frequency. A data segment length giving maximum spectral resolution is shown to exist for each window type and rate of frequency change.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 50 条
  • [41] Comparative study of different Doppler spectrum estimator implementations
    Madeira, MM
    Tokhi, MO
    Ruano, MG
    ALGORITHMS AND ARCHITECTURES FOR REAL-TIME CONTROL 1997, 1997, : 281 - 286
  • [42] The effect of blood acceleration on the ultrasound power Doppler spectrum
    Matchenko, O. S.
    Barannik, E. A.
    ACOUSTICAL PHYSICS, 2017, 63 (05) : 596 - 603
  • [43] Spectrum correction of laser Doppler velocimeter based on Labview
    Zhou J.
    Long X.
    Wei G.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (01): : 9 - 14
  • [44] The effect of blood acceleration on the ultrasound power Doppler spectrum
    O. S. Matchenko
    E. A. Barannik
    Acoustical Physics, 2017, 63 : 596 - 603
  • [45] EFFECT OF FREQUENCY-DEPENDENT PROCESSES ON PULSED DOPPLER SAMPLE VOLUME
    FISH, PJ
    COPE, JA
    ULTRASONICS, 1991, 29 (04) : 275 - 282
  • [46] A pulsed Doppler ultrasonic system design for measuring the viscoelasticity of soft tissue
    Hou, CR
    Chung, KC
    Chiu, YH
    Chen, JT
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 466 - 467
  • [47] Range-Doppler technique applied to underwater pulsed laser system
    Illig, David W.
    Makrakis, Nicholas
    Mullen, Linda J.
    OCEAN SENSING AND MONITORING XIV, 2022, 12118
  • [48] Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
    Vajhi, A. R.
    Mirshahi, A.
    Dezfouli, Mokhber M. R.
    Masoudifard, M.
    Veshkini, A.
    Sorouri, S.
    Torki, E.
    Azizzadeh, M.
    Ghiadi, A. J.
    IRANIAN JOURNAL OF VETERINARY RESEARCH, 2013, 14 (01) : 42 - 49
  • [49] The effect of echo contrast agent on Doppler velocity measurements
    Yokoyama, N
    Schwarz, KQ
    Chen, XC
    Steinmetz, SD
    Becher, H
    Schimpky, C
    Schlief, R
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (05) : 765 - 770
  • [50] QUANTUM CONTINUOUS MEASUREMENTS: THE SPECTRUM OF THE OUTPUT
    Barchielli, A.
    Gregoratti, M.
    QUANTUM PROBABILITY AND RELATED TOPICS, 2008, 23 : 63 - 76